Terra OD006, OD006-55 Quick Start Manual

Optical receivers OD006, OD006-55
Product description
Optical receivers OD006, OD006-55 (in text – receivers) are intended for FTTH (Fiber to the Home) applications to convert signals from optical to electrical and amplify them. Devices are equipped with AGC based on optical input level and optical input power indicator.
OD006-55 has integrated 1550 nm optical lter for WDM (Wavelength-Division Multiplexing) systems.
The receivers are powered from 5 V DC PSU (power supply unit) as well as TV set, set-top box or other USB port.
Devices are intended for indoor use only.
Suitable for moderate and tropical climates.
Installation of the receiver must be done according IEC60728-11 and national safety standards..
Any repairs must be done by a qualied personnel.
Output of PSU +5V must have a short circuit protection.
To ensure safe operation of the receiver follow these instructions:
do not plug the PSU into the mains supply until all cables have been connected correctly;
to disconnect the receiver completely, disconnect the PSU +5V from the mains or unplug USB cable;
the mains socket must be easily accessible;
receiver shall not be exposed to dripping or splashing water and no objects lled with liquids, such as vases, shall be
placed on it;
avoid placing the receiver next to central heating components and in areas of high humidity;
no naked ame sources, such as lighted candles, should be placed on receiver;
if the receiver has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging into the mains;
an optical connector after disconnection emits optical radiation;
avoid looking directly into beam, laser light can cause eye injuries and result in permanent loss of vision.
Structure diagram
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 E-mail: sales@terraelectronics.com, http://www.terraelectronics.com
Vers. 1.02
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
Equipment is double insulated from the mains.
Functional grounding. Connect to the main potential equalization.
TERRA confirms, that this product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065
and RoHS norm EN50581.
TERRA conrms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of
technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
Powering of receiver
Power supply unit 5 V DC with micro USB connector
(power supply is not supplied with receiver)
Requirements for external power supply unit (PSU) for OD006, OD006-55
OD006 is powered from external 5 V DC power supply unit.
Requirements:
• Output voltage: 5 V ± 5%
• Output current: > 0.2 A
• Output connector: micro USB
• Short circuit protection
• Double insulated (marked )
• Meet EN 55022 class B conducted emisions requirements,
measuring with grounded load
Installation instructions
Read the product description and safety instruction rst.
Fiber installation should be done very carefully. Bending radius of bers must be not less 25 mm. All optical connectors and
adaptors should be cleaned before connecting them. Power on the receiver after all cables have been connected correctly.
Technical characteristics
Type OD006 OD006-55
Optical input optical wave lenght 1100-1600 nm 1550 nm
optical input level (AGC range) -6 ...0 dBm
optical return loss > 40 dB noise current density 6.5 pA/Hz
RF output frequency range 47-1006 MHz
impedance 75 return loss 14 dB at 40 MHz-1.5 dB/octave
frequency response ± 0.75 dB
output level (AGC controlled, 4.9% OMI) 80 dBµV
output level (CTB, EN50083-3) 80 dBµV (42 ch.)
output level (CSO , EN50083-3) 80 dBµV (42 ch.)
Power consumption DC 5 V 0.1 A
Operating temperature range -20o ÷ + 50o C
Dimensions/Weight (packed) 72x53x19 mm/0.08 kg
Cable USB A - USB micro connector
(cable is not supplied with receiver)
STB
(set-top-box)
3
or
4
TV
Operating and adjusting
Optical Level Control (OLC) is active at optical input power -6 .. 0 dBm. RF level remains constant while optical input power
uctuates in range of -6 .. 0 dBm. Out of this range receiver continues to operate though OLC is disabled.
The receiver owns optical input power indicator formed from 3 LED. Note the table below for detailed description.
Indication
Left LED Middle LED Right LED
Not glowing Not glowing Glowing red OFF > 0 dBm
Not glowing Not glowing Glowing green ON - 2 .. 0 dBm
Not glowing Glowing green Glowing green ON - 4 .. - 2 dBm
Glowing green Glowing green Not glowing ON - 6 .. - 4 dBm
Glowing green Not glowing Not glowing OFF - 20 .. - 6 dBm
Glowing red Not glowing Not glowing OFF < - 20 dBm
OLC
Optical input power
[
2
5
1
1. Optical input SC/APC
2. OUTPUT - RF signal output connector (F socket)
3. micro USB connector
4. Functional grounding clamp
5. 3 LED optical input power indicator
Loading...