Terra MHD001P, MHD001 User Manual

1
5
6
3
4
2
1
7
mounting hole
mounting hole
8 9
2. 1.
HDMI MODULATORS MHD001, MHD001P
1 - HDMI input connector 2 - DC IN - DC entry 3.5/1.3 mm (DC jack) 3 - RF IN - RF signal input connector (F type) 4 - RF OUT - RF signal output connector (F type) 5 - two-digit LED display 6 - DC voltage indicator 7 - exterior lid (open by hand) 8 - setting mode indicator 9 - HDMI signal presence indicator Figure 1.
Vers. 1.02
PRODUCT DESСRIPTION
HDMI modulators MHD001, MHD001P are intended to encode HDMI video and audio signal to DVB-T signal and modulate
it in VHF and UHF ranges. MHD001P is packed with external mains power supply.
The modulators are intended for indoor use only. Suitable for moderate and tropical climates.
SAFETY INSTRUCTIONS
Installation of the modulator must be done according IEC60728-11 and national safety standards. The modulator is powered from external power supply +12 V. This voltage is not dangerous to life.
Any repairs must be done by a qualied personnel.
To avoid the electric shock follow these instructions: Do not plug mains power supply of the modulator into the mains until all cables have been connected correctly; To disconnect the modulator from mains completely, disconnect plug of modulator power supply from mains socket;
Modulator shall not be exposed to dripping or splashing water and no objects lled with liquids, such as vases, shall be
placed on it;
Avoid placing modulator next to central heating components, near highly compustible materials and in areas of high humidity; Before connecting the modulator to multimedia system, be sure that system is installed in accordance to national safety standards; Devices of multimedia system should have easy access to disconnect them from the mains supply;
No naked ame sources, such as lighted candles, should be placed on modulator;
If the modulator has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before
plugging into the mains;
Do not insert any objects into ventilation openings; The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains;
Mount the modulator on not ammable wall or in not ammable installation box in vertical position with power supply
located on the left. The modulator must be xed with steel screws Ø 3.5-4 mm. The screws are not included in a package;
From top, front and bottom of installed modulator must be at least 10 cm free space.
EXTERNAL VIEW
Manual:
2
INSTALLATION INSTRUCTIONS
Read the safety instruction rst.
Installation of system according standard IEC60728-11 ensures safety of personnel and prevents apparatus against
damaging due to lightning or other sources of overvoltage surges.
To change the modulator settings, open the plastic cover. If RF IN connector on the modulator is not used, connect the 75 load supplied. To wall mount the modulator - screw the modulator to the wall (see Figure 1).
Do not connect TV antennas to modulator RF IN connector directly. If you intend to combine TV signals of antennas
and the modulator, plug in booster with output-to-input isolation 20 dB between antenna output and RF IN connector.
DEFAULT SETTINGS
1. Output channel 21;
2. Protection from unauthorized access OFF (Preset oF);
3. Service name MHD001 CH_21 (Preset 00);
4. Output signal attenuator 15 dB (Preset I5);
5. Output signal ON (Preset on);
6. Region Europe (Preset EU).
OPERATING
CHANGING OF SETTINGS
The modulator has two modes of operating:
1. normal: sets after plug in; Output channel can be selected in normal mode by pressing buttons “-“ or “+” (see tables 2-6).
2. setting: to enter the setting mode press “-“ and “+” buttons simultaneously, to exit setting mode press “-“ and “+” buttons
simultaneously for 1 second. The setting mode is indicated by point after rst digit.
Select of necessary to change parameter by pressing button “-“ and set necessary parameter value by pressing “+” button.
1. Protection from unauthorized access setting (displayed L.C): a) after switching settings mode, indicator displays protection from unauthorized access parameter name L.C; b) select protection from unauthorized access parameter value by pressing “-“ button (displayed o.n or o.F) ;
c) change protection from unauthorized access parameter value by pressing “+“ button. In the normal operation mode the symbol "LO" appears, if you try to change output channel in locked mode and output
channel remains unchanged.
2. service number: a) press “-“ button (displayed n.O); b) press “-“ button again (displayed number from 00 to 99); c) change service name by pressing “+“ button. When the service number is set to number greater that 00, the logical channel number will be added and service name is
set to MHD001 CH_service number. For New Zeland region service name is set according Table 7. When the service number
is set to 00, the logical channel numbering is o󰀨 and service name is set to MHD001 CH_channel number.
Note: set di󰀨erent service numbers for cascaded modulators.
3. output attenuator: a) press “-“ button (displayed A.t); b) press “-“ button again (displayed number from 00 to 30); c) change attenuator value by pressing “+“ button.
4. output signal switching:
a) press “-“ button (displayed r.F); b) press “-“ button again (displayed o.n or o.F); c) switching between RF ON and RF OFF by pressing button “+”, on - RF ON, oF - RF OFF.
5. region switching: a) press “-“ button (displayed r.9); b) press “-“ button again (displayed region name (see Table 1); b) switching between regions by pressing button “+”.
REGION SETTING
Table 1.
Region Displayed Channel tables Europe
EU
Table 2, Table 4
New Zealand
n2
Table 2, Table 4
Australia
AU
Table 3, Table 5
United Kingdom Table 2, Table 4
Russia
rU
Table 2, Table 6
UK
3
REQUIREMENTS FOR EXTERNAL POWER SUPPLY UNIT (PSU) FOR MHD001
• Output voltage +12 V ± 1 V
• Output current > 0.3 A
• Ripple at single and/or double mains frequency < 10 mV p-p
• Ripple & noise < 180 mV p-p
• Output connector type 3.5/1.3 (+) plug or 5.5/2.1 mm (+) plug
• Short circuit protection
• Double insulated (marked )
• Meet EN 55022 class B conducted emisions requirements, measuring with grounded load
Caution (mark on rear side).
Risk of electric shock (mark on rear side).
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled or discarded according to applicable local and national regulations (mark on rear side) .
Equipment intended for indoor usage only (mark on rear side).
This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065 and RoHS norm EN50581.
This product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of technical
equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
PACKAGE CONTENTS
1. Encoder-modulator ................................................................................. 1 pcs.
2. DC power supply adapter from 5.5/2.1 mm to 3.5/1.3 mm ..................... 1 pcs.
3. Load 75 Ω, type F .................................................................................. 1 pcs.
4. External mains power supply +12 V 1 A max. (only for MHD001P) ....... 1 pcs.
5. User manual .......................................................................................... 1 pcs.
TECHNICAL CHARACTERISTICS
Type MHD001 MHD001P
Video input input signal type HDMI
video coding MPEG-4 AVC/H.264, Baseline prole 4.0
Audio input input signal type HDMI
audio coding MPEG-1 Layer II, AAC
H.264 encoder standard MPEG-4 AVC/H.264
Output resolution up to 1920x1080x30p
Transport stream automatic generation
PAT, SDT, PMTs tables
processing
RF output DVB standard DVB-T
frequency range 174 - 230 MHz, 470-862 MHz
MER, typical 32 dB
modulation QAM64
channel bandwidth 7 MHz/ 8 MHz
shoulder attenuation > 36 dB
level/impedance 90 dBμV/75 Ω
output level adjustment 0 ÷ -30 dB by 1 dB step
loop through frequency range/loss 45-862 MHz / ≤ 2.5 dB
Current consumption 12 ± 1 V 300 mA -
Power consumption - 100-240 V~ 50/60 Hz 4 W
Operating temperature 00 C ÷ +400 C
Dimensions/Weight (packed) 133x63x39 mm/0.18 kg 133x63x39 mm/0.34 kg
pr.
pr.
pr.
software control
pr.
4
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 E-mail: sales@terraelectronics.com, http://www.terraelectronics.com
UHF BAND CHANNELS
(REGIONS: EUROPE, NEW ZEALAND, UNITED KINGDOM, RUSSIA)
UHF BAND CHANNELS (REGION: AUSTRALIA)
Bandwidth Channel Displayed Center freq. 5 05 177.5 MHz
6 06 184.5 MHz 7 07 191.5 MHz 7 MHz 8 08 198.5 MHz 9 09 205.5 MHz 10 10 212.5 MHz 11 11 219.5 MHz 12 12 226.5 MHz
Bandwidth Channel Displayed Center freq. 6 06 177.5 MHz
7 07 184.5 MHz 8 08 191.5 MHz 7 MHz 9 09 198.5 MHz 9A 10 205.5 MHz 10 11 212.5 MHz 11 12 219.5 MHz 12 13 226.5 MHz
Bandwidth Channel Displayed Center freq. 6 06 178 MHz
7 07 186 MHz 8 08 194 MHz 8 MHz 9 09 202 MHz 10 10 210 MHz 11 11 218 MHz 12 12 226 MHz
VHF BAND CHANNELS
(REGIONS: EUROPE, NEW ZEALAND, UNITED KINGDOM)
Table 4
Table 5
Table 6
Table 7
Bandwidth Channel Center freq. 21 474 MHz
22 482 MHz 23 490 MHz 24 498 MHz 25 506 MHz
26 514 MHz 27 522 MHz 28 530 MHz 29 538 MHz 30 546 MHz 31 554 MHz 32 562 MHz 33 570 MHz 34 578 MHz 35 586 MHz 36 594 MHz 37 602 MHz 38 610 MHz 39 618 MHz 40 626 MHz 41 634 MHz 42 642 MHz 43 650 MHz 8 MHz 44 658 MHz 45 666 MHz 46 674 MHz 47 682 MHz 48 690 MHz 49 698 MHz 50 706 MHz 51 714 MHz 52 722 MHz 53 730 MHz 54 738 MHz 55 746 MHz 56 754 MHz 57 762 MHz 58 770 MHz 59 778 MHz 60 786 MHz 61 794 MHz 62 802 MHz 63 810 MHz 64 818 MHz 65 826 MHz 66 834 MHz 67 842 MHz 68 850 MHz 69 858 MHz
Bandwidth Channel Center freq. 20 473.5 MHz
21 480.5 MHz 22 487.5 MHz 23 494.5 MHz 24 501.5 MHz 25 508.5 MHz
26 515.5 MHz 27 522.5 MHz 28 529.5 MHz 29 536.5 MHz 30 543.5 MHz 31 550.5 MHz 32 557.5 MHz 7 MHz 33 564.5 MHz 34 571.5 MHz 35 578.5 MHz 36 585.5 MHz 37 592.5 MHz 38 599.5 MHz 39 606.5 MHz 40 613.5 MHz 41 620.5 MHz 42 627.5 MHz 43 634.5 MHz 44 641.5 MHz 45 648.5 MHz 46 655.5 MHz 47 662.5 MHz 48 669.5 MHz 49 676.5 MHz 50 683.5 MHz 51 690.5 MHz 52 697.5 MHz 53 704.5 MHz 54 711.5 MHz 55 718.5 MHz 56 725.5 MHz 57 732.5 MHz 58 739.5 MHz 59 746.5 MHz 60 753.5 MHz 61 760.5 MHz 62 767.5 MHz 63 774.5 MHz 64 781.5 MHz 65 788.5 MHz 66 795.5 MHz 67 802.5 MHz 68 809.5 MHz 69 816.5 MHz 70 823.5 MHz 71 830.5 MHz 72 837.5 MHz 73 844.5 MHz 74 851.5 MHz 75 858.5 MHz
Table 2 Table 3
VHF BAND CHANNELS
(REGION: AUSTRALIA)
VHF BAND CHANNELS
(REGION: RUSSIA)
SERVICE NAMES FOR NEW ZEALAND
Displayed service
number
Service name
01
SKY1
02
SKY2
03
SKY3
04
SKY4
05
SKY5
06
APPLE TV 1
07
APPLE TV 2
08
APPLE TV 3
09
APPLE TV 4
10
APPLE TV 5
11
BLU-RAY 1
12
BLU-RAY 2
13
BLU-RAY 3
14
BLU-RAY 4
15
BLU-RAY 5
Loading...