Teltronic U PTRUNK25RF800, PTRUNK25RF450 Users manual

CLASSIFICATION:
RF Unit USER AND INSTALLATION MANUAL
PRODUCT:
CODE:
VERSION:
RF Unit
01
REVISION:
01
DATE:
General information Internal document
DOCUMENT MAINTENANCE
THIS DOCUMENT HAS 16 PAGES
EDIT. DATE AUTHOR DESCRIPTION
1.0 27/12/07 José Roman RF Unit User and Installation Manual.
1.1 09/10/08 Javier Córdova General revision.
09/10/08
DOCUMENT APPROVAL
ACTIVITY NAME DATE SIGNATURE
Prepared
Revised
Project Manager
Approved
R&D Director
01.01.00/1 Rev.1
RF Unit USER AND
Code: D168X01_DDS09
INSTALLATION
MANUAL
Disclaimer
Although every reasonable effort has been made to ensure the accuracy of the information contained herein and any other referred document, this should not be construed as a commitment on the part of Teltronic S.A. Unipersonal, and the liability of Teltronic S.A. Unipersonal for any errors and omissions shall be limited to the correction of such errors and omissions. Teltronic S.A. Unipersonal welcomes any comment as a way to improve any delivered documentation.
The information contained herein has been prepared for the use of appropriately trained personnel, and it is intended for the purpose of the agreement under which the information is submitted. Any party using or relying upon this information assumes full responsibility for such use and in no event shall Teltronic S.A. Unipersonal be liable to anyone for especial, collateral, incidental, or consequential damages in connection with or arising out of the use of this information.
The information or statements given in these documents regarding the suitability, capacity or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Teltronic S.A. Unipersonal and the customer.
Teltronic S.A. Unipersonal reserves the right to revise these documents and to make changes to its content at any time, without prior notification.
Copyrights
No part of the information contained herein and the other referred documents may be copied, distributed or transmitted by any means to any other party without prior written permission of Teltronic S.A. Unipersonal. The distribution of this document may be also covered by NDA (non-disclosure agreement) between Teltronic S.A. Unipersonal and the receiver.
Please also note that part of these contents even may be covered by patent rights.
This document, the referred documents and the described product are considered protected by copyright according to the applicable laws.
Teltronic and the Teltronic logo are registered trademarks of Teltronic S.A. Unipersonal.
Copyright © Teltronic S.A. Unipersonal. All rights reserved.
Date: 09/10/08 Page: 2 of 16
01.01.00/1 Rev.1
RF Unit USER AND
Code: D168X01_DDS09
INSTALLATION
CONTENTS:
1.
INTRODUCTION ......................................................................................................... 4
2.
UNPACKING AND CHECKING .................................................................................. 5
3.
PREVIOUS CONSIDERATIONS................................................................................. 5
4.
INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY ............ 5
5.
EQUIPMENT DESCRIPTION ...................................................................................... 7
5.1.
FRONT VIEW ....................................................................................................... 7
5.2.
REAR VIEW ......................................................................................................... 8
5.3.
MODULES ............................................................................................................ 9
MANUAL
Date: 09/10/08 Page: 3 of 16
6.
7.
8.
INSTALLATION GUIDE ............................................................................................ 12
6.1.
LOCATION ......................................................................................................... 12
6.2.
POWER SUPPLY CONNECTION ...................................................................... 12
6.3.
ANTENNA CONNECTION ................................................................................. 13
6.4.
SWITCHING ON THE RF UNIT .......................................................................... 13
CONFIGURATION .................................................................................................... 14
INCIDENTS ............................................................................................................... 14
8.1.
ALARMS ............................................................................................................ 14
01.01.00/1 Rev.1
!
RF Unit USER AND
Code: D168X01_DDS09
INSTALLATION
MANUAL
1. INTRODUCTION
The RF Unit is the RF transceiver of Teltronic P25 systems, with a transmitter output power of 100W. Therefore, this is a mandatory module in the infrastructure P25 network. It is manufactured following a robust mechanical modular design which allows simple and economic maintenance.
The RF Unit is available in the following frequency bands:
380 - 400 MHz
410 - 430 MHz
450 - 470 MHz
764 - 806 MHz
806 - 870 MHz
The modules that form the RF Unit are:
RPS (Repeater Power Supply P25)
RPA P25 (Repeater Power Amplifier P25)
RTX P25 (Repeater Transmitter P25)
RRX P25(Repeater Receiver P25)
BSYNC (RF Unit Synchronism) - OPTIONAL
RCPU P25(Repeater Control Processing Unit P25)
The proper operation of any electronic device depends on its correct use. It is
therefore recommended to follow the instructions in this manual.
Date: 09/10/08 Page: 4 of 16
CAUTION: Switch the RF Unit off before inserting/removing any of its modules.
01.01.00/1 Rev.1
RF Unit USER AND
Code: D168X01_DDS09
INSTALLATION
MANUAL
2. UNPACKING AND CHECKING
The following elements are supplied in the box:
RF Unit 50Ω / 20W load termination Power Supply Cable Maintenance Cable Two Ethernet Cables
The equipment is supplied with all the modules already assembled in the rack. The modules in the basic configuration are: Power Supply module (RPS), Power Amplifier (RPA P25), Transmitter (RTX P25), Receiver (RRX P25) and Control (RCPU P25). Synchronism module (BSYNC) is necessary for testing purposes.
IMPORTANT: if any of these elements is missing or damaged, contact your dealer and / or installer.
Date: 09/10/08 Page: 5 of 16
3. PREVIOUS CONSIDERATIONS
This manual contains information on instructions for installation, maintenance and use. Read the following pages before using this equipment.
Do not switch on the RF Unit without having previously connected the TX antenna and the 50 load to the TNC connector. The equipment may be seriously damaged. It is important to use an antenna adjusted to the RF Unit transmitter frequency band.
INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY
The equipment has been designed to fulfil the applicable compliance regulations.
The equipment complies with Part 15 of the FCC Title 47 of the Code of Federal Regulations. Operation is subject to the condition that this device does not cause harmful interference.
The equipment complies with the applicable Part 90 of the FCC Title 47 of the Code of Federal Regulations.
01.01.00/1 Rev.1
Loading...
+ 11 hidden pages