TDS.11..
Vishay Telefunken
3 (9)
Rev. A1, 02-Jun-99
www.vishay .de • FaxBack +1-408-970-5600Document Number 83124
Orange red (TDSO115. , TDSO116. )
Parameter Test
Conditions
Type Symbol Min Typ Max Unit
Luminous intensity per segment
(digit average)
1)
IF = 10 mA TDSO
1150/1160
I
V
450
m
cd
Dominant wavelength IF = 10 mA
l
d
612 625 nm
Peak wavelength IF = 10 mA
l
p
630 nm
Angle of half intensity IF = 10 mA ϕ ±50 deg
Forward voltage per segment or DP IF = 20 mA V
F
2 3 V
Reverse voltage per segment or DP IR = 10 mA V
R
6 15 V
1)
I
Vmin
and IV groups are mean values of
segments a to g
Yellow (TDSY115. , TDSY116. )
Parameter Test
Conditions
Type Symbol Min Typ Max Unit
Luminous intensity per segment
(digit average)
1)
IF=10mA
TDSY
1150/1160
I
V
450
m
cd
Dominant wavelength IF=10mA
l
d
581 594 nm
Peak wavelength IF=10mA
l
p
585 nm
Angle of half intensity IF=10mA
ϕ ±50 deg
Forward voltage per segment or DP IF=20mA
V
F
2.4 3 V
Reverse voltage per segment or DP IR=10mA
V
R
6 15 V
1)
I
Vmin
and IVgroups are mean
values of
segments a to g
Green (TDSG115. , TDSG116. )
Parameter Test
Conditions
Type Symbol Min Typ Max Unit
Luminous intensity per segment
(digit average)
1)
IF = 10 mA TDSG
1150/1160
I
V
450
m
cd
Dominant wavelength IF = 10 mA
l
d
562 575 nm
Peak wavelength IF = 10 mA
l
p
565 nm
Angle of half intensity IF = 10 mA ϕ ±50 deg
Forward voltage per segment or DP IF = 20 mA V
F
2.4 3 V
Reverse voltage per segment or DP IR = 10 mA V
R
6 15 V
1)
I
Vmin
and IV groups are mean values of
segments a to g