Teledyne PCIe Summit Quick Start

Page 1
1
Introduction
Use this document for quick installation and setup.
If you experience problems or need more information, see the Summit Z3-16 User Manual on the PETracer Installation CD or at the Teledyne LeCroy web site.
2
Components
The package includes the following components:
2
Summit Z3-16™ exerciser card with CLKREQ# support
Power Adapter
x16 to x1 Edge Adapter
x16 to x4 Edge Adapter
x16 to x8 Edge Adapter
USB and Ethernet cables
•PETra cer Software program CD-ROM Depending on configuration, the package may also include:
PCI Express Test Platform for Summit™ Z3-16 Exerciser with CLKREQ# and SRIS Support
Summit Z3-16
Quick Start
Please see the Readme file on the installation CD for the latest software version and for host machine requirements.
Please see the Summit Z3-16 User Manual on the installation CD for component specifications and further details.
Summit Z3-16 Exerciser Card with CLKREQ# support
3
Unpacking the Exerciser
Unpacking the Exerciser
Inspect the received shipping container for any damage. Unpack the container and account for each of the system
Inspect the received shipping container for any damage. Unpack the container and account for each of the system
components listed on the accompanying packing list. Visually inspect each component for absence of damage.
components listed on the accompanying packing list. Visually inspect each component for absence of damage.
In the event of damage, notify the shipper and Teledyne LeCroy. Retain all shipping materials for shippers inspection.
In the event of damage, notify the shipper and Teledyne LeCroy. Retain all shipping materials for shipper’s inspection.
Page 2
4
Shown here is an example of the Summit Z3-16 Exerciser inserted into the PCI Express Test Platform for Host emulation.
Exerciser Card - Front
Power Socket: For the 12 V DC Power Adapter USB Type B Host Machine Connector: Links an Exerciser to the host machine for the purpose of downloading scripts and controlling the behavior of the Exerciser. Note: Use either USB or Ethernet, not both. Ethernet Port: GIGE Connectivity allows connection to an Ethernet network and sharing of Analyzer/Exerciser resources by multiple
engineers. Note: Use either USB or Ethernet, not both.
Power LED: On/Off x16 PCIe Edge Connector: Use the Edge Adapters to connect to x8, x4, or x1 slots.
Exerciser Card - Rear
Train LED: Indicates whether the link is TRAINED or not. Transmitter and Receiver LEDs: 16 LEDs for Transmitting lanes and 16 LEDs for Receiving lanes, with Green = no error and Yellow =
error.
Speed LEDs: 3 LEDs indicate operating speed: 8 GT/s for Gen3, 5 GT/s for Gen2, and 2.5 GT/s for Gen1.
Page 3
5
Installing the Software
PETracer software operates all of Teledyne LeCroy’s PCI Express protocol Analyzer and Exerciser products: The PETracer software is installed on a Microsoft Install the PETracer software on the host machine before attaching the Analyzer to the system:
1. Insert the CD into the CD ROM drive of the host machine that will control the Analyzer. The installation window opens and displays links to the software installation, user manuals, app notes and data sheets.
2. Select Install PCIe Protocol Suite and follow the onscreen instructions. The PETracer software installs automatically on the host machine’s hard disk. During installation, all necessary USB drivers will be installed.
3. To start the application, launch the PETracer program from the Start menu:
Start > All Programs > LeCroy > PETracer > LeCroy PETracer
User manuals for your LeCroy PCIExpress products can be found in: Start > All Programs > LeCroy > PETracer > PCIe Protocol Suite Documents.
Software installation can also be downloaded from the Teledyne LeCroy website.
6
Setting Up and Connecting the Summit Z3-16 Exerciser
You can connect the Exerciser to the host machine using USB or Ethernet.
®
Windows®-based host machine and serves as the interface for the Analyzer.
Using an Ethernet Connection
To set up the Exerciser using an Ethernet connection:
1. Install PETracer software on the host machine.
2. Connect the Exerciser to a 100-volt to 240-volt, 50 Hz to 60 Hz, 120 W power outlet using the provided power cord.
3. Connect the Ethernet cable between the Ethernet port on the Exerciser and a Ethernet port in the local network.
4. Power on the Exerciser by plugging the 12-V DC power cable into the Exerciser Card and then into the PCI Express Test Platform for Summit™ Z3-16 Exerciser with CLKREQ# and SRIS Support.
Note 1: No driver installation is needed for Summit Z3-16 to
operate over a network.
Note 2: At power-on, the Exerciser initializes and performs a
self-diagnostic.
Note 3: Summit Z3 is configured at the factory to use dynamic IP
setting and will get all required network parameters from the DHCP server on your network. If the DHCP server is not available, or to connect Summit Z3 directly to the host machine, you can reconfigure the network settings through the PETracer software (see Summit Z3-16 User Manual).
Connecting to Summit Z3-16 in the software
Start the PETracer software and perform the following procedure to connect to a Summit Z3-16 analyzer over the network.
1. Select the Setup > All connected devices… menu in the PETracer application to display the Analyzer Devices dialog.
2. Select your Summit Z3 device in the list and press the Connect button to execute the connection procedure. After the connection is established, the application displays the Connection Properties dialog.
3. Select an option:
Automatically connect to the device: When the
application is started or when the named device appears on the network while the PETracer application is running on this computer, the PETra c er application will try to connect to the named device.
Ask if I want to connect to the device: When the
application is started or when the named device appears on the network while the PETracer application is running on this computer, the PETra c er application will display a message box allowing you to connect to the named device.
Take no action: When you start the application or when
the named device appears on the network while the PETracer application is running on this computer, you must connect manually to use the named device.
Note: When you close the application on this computer (or
you perform manual disconnect), the application disconnects from the device.
4. Press OK in the Connection Properties dialog. After you finish the connect procedure, the Summit Z3-16 to which you have connected is marked as Ready and you can use it for recording.
The Summit devices in the list are marked:
Locked: Some other client on the network is already connected to that device
Ready to connect: Available for connection
Note: To disconnect from a device, display this dialog,
select the device, and click the Disconnect button.
Note 2: Summit Z3 will not appear in the Analyzer Device dialog
if it is connected on a different Subnet on your local network. You can connect to it on the Subnet by specifying its IP address in the Add Device dialog.
Page 4
Using a USB Connection
To set up the Exerciser using a USB connection:
1. Install PETracer software on the host machine.
2. Connect the Exerciser to a 100-volt to 240-volt, 50 Hz to 60 Hz, 120 W power outlet using the provided power cord.
3. Connect the USB port to a USB port on the host machine using a USB cable.
4. Power on the Exerciser by plugging the 12-V DC power cable into the Exerciser Card and then into the PCI Express Test Platform for Summit™ Z3-16 Exerciser with CLKREQ# and SRIS Support.
Note: At power-on, the Exerciser initializes and performs a
self-diagnostic.
7
Connecting to the DUT and Generating Traffic
5. Summit Z3 will be recognized by the host machine as a USB device.
Follow the Microsoft instructions for the automatic installation of the Exerciser as a USB device on your analyzing host machine. (The required USB drivers are included on the Installation CD and were installed on your system when you installed the software.) Click Finish when you see the message that says “Windows has finished installing the software that your new hardware requires” and the file has been installed in your host machine.
6. Start the PETracer software, so you can start working with Summit Z3.
®
Windows® on-screen Plug-and-Play
The Summit Z3-16 Exerciser Card can test both the host and device sides of a PCI Express link using the card alone or with the Test Platform.
For Motherboards and Host Controllers
1. If not already powered off, power off the Summit Z3-16 Exerciser Card and the DUT.
2. Insert the edge connector into a PCI Express slot in the DUT. To connect to a x1, x4, or x8 slot, use an Edge Adapter.
For PCI Express Add-on Cards
1. If not already powered off, power off the Summit Z3-16 Exerciser Card, PCI Express Test Platform for Summit™ Z3-16 Exerciser with CLKREQ# and SRIS Support, and the DUT.
2. Insert the Exerciser Card into the PCI Express Test Platform for Summit™ Z3-16 Exerciser with CLKREQ# and SRIS Support.
3. Insert the male edge connector of the DUT into the PCI Express slot.
Power on the Exerciser and then DUT Important: Power on the Exerciser Card before you power on the DUT.
1. Power on the Exerciser Card.
2. If testing a motherboard, power on the motherboard.
3. Open the PETracer application on the host machine. The Exerciser is now ready for traffic generation.
Generating Traffic
1. Use the default settings or set options in the Generation Options dialog box (see Summit Z3-16 User Manual).
2. Start the PETracer™ software, if necessary, and open an existing script file or create a new script.
3. Start generation by clicking the Start Traffic Generation button on the Status bar. This action causes the software to download the script to the device. After download completes, the device starts executing the script. As the script executes, the Status bar displays script progress. Note: Script execution can be terminated at any time by clicking the
Stop Generation button on the toolbar.
Teledyne LeCroy Customer Support
Online Download Periodically check the Teledyne LeCroy Protocol Solutions Group web site for software updates and other support related to this product. Software updates are available to users with a current Maintenance Agreement.
Trademarks and Servicemarks
Teledyne LeCroy and Summit T3-16 and Z3-16 are trademarks of Teledyne LeCroy. Microsoft and Windows are registered trademarks of Microsoft Inc. All other trademarks are property of their respective companies.
Mail: 3385 Scott Blvd., Santa Clara, CA 95054-3115 Web: teledynelecroy.com/Support/SoftwareDownload/ E-mail: psgsupport@teledynelecroy.com Tel: (800) 909-7112 (USA and Canada) Tel: (408) 653-1260 (worldwide)
Changes
Product specifications are subject to change without notice. Teledyne LeCroy reserves the right to revise the information in this document without notice or penalty.
© 2014 Teledyne LeCroy, Inc. All rights reserved. Part Number: 923899-00 Rev A This document may be printed and reproduced without additional permission, but all copies should contain this copyright notice.
Loading...