WaveStar Software Overview
WaveStar Software connects Tektronix TDS/THS/CSA oscilloscopes to your Windows 95,
Windows 98, and Windows NT 4.0 applications.
This CD contains a free, full-functioning version of WaveStar Software for Oscilloscopes;
however, the demo software expires thirty days after installation.
If you are interested in continued use of WaveStar Software, place an order for WSTRO
WaveStar Software for Oscilloscopes with Tektronix or an authorized Tektronix distributor
any time during the thirty day trial period.
This CD also contains WaveStar Reader, a free program that lets you open and view
datasheet and notebook files created by WaveStar for Oscilloscopes.
WaveStar Software Features
Capture
H Setup communication to instruments through the WaveStar Connection Wizard
H Extend communication to simple instruments, such as frequency generators, by
defining the User-Specified Proxy (driver)
H The Explorer View displays these instruments and reveals their corresponding
properties
H Drag, and drop instrument data into an active data sheet and begin analysis at your PC
Analyze
H Analyze, annotate, and record information in a variety of data sheets
H Capture and graphically view multiple waveforms on a graticule, with the same scale
and position as on the oscilloscope
H Cursor measurements, gates, zoom function, and annotation
H Capture measurement waveforms and data easily without the need for programming
Control
H Step away from your desk and have WaveStar automatically capture data changes
H Establish instrument links to automatically update new measurements
H Control waveform information locally or over the network
Document
H Insert information in Microsoft Office or Windows applications
H Print banner function allows printing of long record lengths
1
2
Free 30-day Demo Installation Instructions
Free 30-day Demo Installation Instructions
System Requirements
To install and run WaveStar software, you must have an IBM-compatible PC with the
following installed:
H Windows 95, 98, or Windows NT 4.0
H 16 MB RAM or greater recommended
H CD-ROM drive, 4X or better
H Super VGA monitor or better
H 20 MB disk space
H An appropriate PC communication interface:
H National Instruments IEEE 488.2 interface card
H PC compatible serial communications COM port and RS-232 cable
H 10BaseT Ethernet card
Installing WaveStar Software
Follow the steps below to install either the WaveStar Software for Oscilloscopes free
30-day demo, or the free WaveStar Reader program:
1. Insert the CD-ROM into the CD-ROM drive. The installer file on the CD -ROM should
self start within about thirty seconds. If it does not self start, Select Start > Run and
enter
<cd drive letter>:\install.exe in the dialog and click OK.
2. Select the WaveStar for Oscilloscopes tab. The next screen shows the WaveStar for
Oscilloscopes information screen with a menu bar at the top of the screen.
3. Click Install. The installation wizard appears next and walks you through the rest of
the installation process. Follow the instructions in the wizard.
4. The installation wizard may state that Microsoft DCOM for Windows 95 must be
installed on your machine. WaveStar Software requires DCOM to interact with
Microsoft applications. Click Next to install DCOM.
5. If DCOM installation is needed, the install wizard shows the License Agreement for
Microsoft DCOM for Windows 95. If you accept all of the terms in the license
agreement, click Ye s. If you do not accept the terms of the agreement, click No to end
the setup process.
6. Next you will be prompted to install Tektronix TekVisa software, Tektronix’ version of
VISA. VISA is another communication application that is required for WaveStar
software to talk to your instrument.
3
4
Free 30-day Demo Installation Instructions
Free 30-day Demo Installation Instructions
If you have another version of VISA already installed on your PC, you can choose to
use the existing version, or you can replace that version with the provided TekVisa.
If you choose to install TekVisa, follow the steps below:
a. The Tektronix VISA installer starts. Click Next when you have read the preliminary
information.
b. In the Choose Destination Folder dialog, select the directory location where you
want Tektronix VISA installed. Click Next.
c. In the next Choose Destination Folder dialog, select the directory location whe re
you want Tektronix VISA VXI Plug and Play components installed. Click Next.
d. In the Setup Type dialog, select the type of installation you would like to perform
and click Next:
Custom Setup Type: Allows you to choose which components to install.
Standard Setup Type: Installs all VISA files (recommended).
e. The Start Copying Files dialog displays the directory location of where VISA and
VXI Plug and Play files will be installed. If you want to change this information,
use the Back button. If this information is correct, click Next.
f. When the installation is complete, the Setup Complete dialog appears. Click Finish
to dismiss this dialog.
The Welcome to WaveStar for Oscilloscopes dialog appears. Read the information in
7.
the dialog and click Next.
8. Read the WaveStar Software for Oscilloscopes License Agreement. If you accept all of
the terms in the license agreement, click Ye s . If you do not accept the terms of the
agreement, click No to end the setup process.
9. The Installation Type dialog box appears. Click WaveStar Softwa re DEMO to install
the free demo software, or click WaveStar Reader to install the free WaveStar Reader
software.
10. The Choose Destination Location dialog appears, asking you to select a directory
location for the WaveStar files. Click Next to accept the default location, or click
Browse... to select a location other than the default.
11. After all files have been installed, the Restart Windows dialog appears. It is
recommended that you restart Windows to allow proper operation of WaveStar
Software for Oscilloscopes. Click OK.
UsingthisFreeDemo
This demo version functions exactly as the full version, but expires after thirty days.
For detailed information on how to use this software, refer to the online help or the
.PDF-format user manual on the CD-ROM.
5
6
Free 30-day Demo Installation Instructions
Free 30-day Demo Installation Instructions
Technical Support
You have a number of different ways of reaching Tektronix Technical Support. When
contacting Technical Support have your name, telephone number, description of problem,
steps needed to duplicate problem, instruments used, and software version and serial
numbers.
If you have exhausted all sources of WaveStar information and resources and find that you
need to contact Tektronix Technical Support, use one of the following contact methods.
Telephone. Call Tektronix toll free in the US at 1-800-TEK-WIDE (1-800-835-9433)
extension 2400, Monday through Friday, 6:00 am to 5:00 pm Pacific Standard Time.
E-mail. Submit questions by email to
support@ tektronix.com. Include your name, phone number, description of the problem,
steps needed to duplicate the problem, instrument used, and WaveStar software version in
the body of your message.
World Wide Web. For further information on contacting Technical Support, or for an
up-to-date list of field offices, visit our WWW site at www.tektronix.com.
Ordering Information
Contact your Tektronix distributor to order WaveStar software. Use the information below
when ordering:
WSTRO WaveStar Software for Oscilloscopes. Includes one CD-ROM and a user manual.
WSTROU Upgrade to WSTRO WaveStar Software for Oscilloscopes from WaveStar Software
3.1. Includes one CD-ROM and a user manual. You are required to have WaveStar
Software 3.1 to install WSTROU Upgrade to WSTRO WaveStar Software for Oscillo scopes from WaveStar Software 3.1.
For further ordering information, contact Tektronix:
World Wide Web: http://www.tek.com
ASIAN countries: (65) 356-3900
Australia & New Zealand: 61 (2) 9888-0100
Austria, Central Eastern Europe, Greece, Turkey, Malta, and Cyprus: +43 2236 8092 0
Belgium: +32 (0) 2715 89 70
Brazil and South America: 55 (11) 3741-8360
Canada: 1 (800) 661-5625
Denmark: +45 (44) 850 700
Finland: +358 (9) 4783 400
France & North Africa: +33169868181
Germany: +49 (221) 94 77 400
Hong Kong: (852) 2585-6688
India: 91 (80)-2275577
Italy: +39 (2) 25086 1