Tektronix wfm7200 Release Notes

xx
WFM7200
ZZZ
Waveform Monitor
Release Notes
This document supports software version 3.0.X.
www.tektronix.com
*
077-0673-01
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. B o x 5 0 0 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worl dwid e, vi sit www.tektronix.com to nd contacts in your area.
Release notes
New features
Features and benets
This document describes the key features and known limitations of software version 3.0.X of the WFM7200 Waveform Monitor. Some of these notes apply only to instruments with specic options installed. A list of available instrument options can be found at the Tektronix Web site (www.tektronix.com).
Software version 3.0.X is a maintenance release and provides no new features.
Multiformat, multistandard video monitoring
WFM7200 includes standard auto-detection of HD/SD-SDI and multiple
Dual Link video formats
Composite analog (PAL/NTSC) video support (Option CPS)
Simultaneous monitoring (with Option SIM) allows monitoring of two
HD/SD-SDI inputs or one HD/SD-SDI input and one CPS input. Option 3G is required for 3G-SDI format support
Multiple Input Mode allows monitoring of two to four SDI inputs
simultaneously (4-input mode requires Option 2SDI)
Upgradeable to 3G-SDI (Level A and Level B) format support (Option 3G)
Comprehensive audio monitoring (Option AD or DPE)
Up to 16-channel audio monitoring for embedded audio
Multichannel Surround Sound display and exible Lissajous display
(Audio Surround Sound Display licensed from Radio Technische WerksüttenGmbHandCo. KG(RTW))
Audio Loudness monitoring to ITU-R BS.1770-2.
Support for analog, digital, and embedded audio. (Option AD)
olby Digital (AC-3), Dolby Digital Plus, and Dolby E (Option DPE)
D
Comprehensive Dolby metadata decode and display (Option DPE)
Dolby E Guard Band meter with user-dened limits (Option DPE)
WFM7200 Waveform Monitor v3.0.X Release Notes 1
Release notes
Unmatched disp
lay versatility
FlexVu™, the most exible four-tile display, suited for various application
needs to incre
ase productivity
Tektronix-patented Diamond and Arrowhead displays for gamut
monitoring
Tektronix-patented Timing and Lightning displays
Tektronix-patented Spearhead display and Luma Qualied Vector
(LQV™) display facilitate precise color adjustment for post-production applicati
ons (Option PROD)
Stereoscopic 3D video displays for camera alignment and producti
on/post-production applications (Option S3D)
Black picture and Tektronix-patented frozen picture detection
Advanced ANC data monitoring
Simultaneous CEA708/608 Closed Caption monitoring; Teletext and
OP47 subtitle monitoring
Detect and decode ANC data including AFD, WSS, Video Index, TSID,
V-Chip, Broadcast Flag/CGMS-A, VITC, LTC, and ANC TC ARIB STD-B35/B37/B39, TR-B22, and TR-B23 support
In-depth digital data analysis helps quickly resolve difcult content quality and reliability issues (Option DAT)
Standard and user-denable Safe Area graticules facilitate editing and format conversion tasks, reducing the need for rework
Active Format Description (AFD) detection, decode, and automatically adjusted graticule in Picture display enables easy identication of aspect-ratio
lated issues
re
Superior physical layer signal measurement
High-performance real-time eye pattern display, jitter measurements, and
patented cable length measurement (Option PHY3)
Most comprehensive eye pattern measurements including eye amplitude,
rise/fall time, and overshoot/undershoot measurements as well as Tektronix jitter waveform display (Option PHY3)
2 WFM7200 Waveform Monitor v3.0.X Release Notes
Release notes
Unmatched usab
ility
CaptureVu® advanced video frame data capture simplies troubleshooting
and equipment
setup
32 instrument presets for quick recall of commonly used congurations
tailored to
engineers or operators
Front-panel USB port enables easy transfer of presets, captured video
frame data,
screenshots, and error log
Front-panel headphone port enables quick verication of selected audio
pair
Intuitive menu structure and context-sensitive help
Extensive alarms, status reporting, and error logging
Bright, crisp, high-resolution LED backlight display
SNMP and Ethernet remote interface capabilities and GPI control
facilitate centralized monitoring and control.
WFM7200 Waveform Monitor v3.0.X Release Notes 3
Release notes
General limit
Dolby operat
Option DPE
ations
ion with
This release h as the following general limitations. Topics are listed in alphabetical order.
For listening mode selections other than FULL or EX, clipping may occur. For example, if the Dolby Digital input is 3/2 with full-scale test tones and Stereo listening mode is selected, clipping will likely occur. To av oid cl Dialnorm+RF in CONFIG > Audio Input/Outputs > Dolby D (AC-3) Setup > Dialnorm&DynRng.
When in Channel Mode 2/2 and Phantom Listening Mode, the Surround Sound display (AUDIO tile) shows the Ls and Rs levels attenuated by 3 dB instead of displaying at full amplitude for this channel mode/listening mode combination.
When in Channel Mode 3/0 and 3-Stereo Listening Mode, the Surround Sound display (AUDIO tile) shows the C level attenuated by 3 dB instead of displaying at full amplitude for this channel mode/listening mode combi
The Dolby E/Dolby Digital decoder will pass through PCM audio at 48 kHz
uencies or less. Audio frequencies above this will not pass through and
freq may cause noise or distortion on both the bars and the audio outputs. If PCM audio at frequencies greater than 48 kHz is used, choose either AES A or B as the input source.
ipping, choose either compression mode, Dialnorm+Line or
nation.
Firmware update to
version 3.X
Firmware update with any
Dolby option
The rst time the instrument rmware is updated to version 3.X, the upgrade process must be run twice in order for the rmware to be properly installed. Subsequent upgrades will require only one attempt to upgrade the rmware.
If you are updating rmware from 2.X to 3.X via U SB, after the instrument reboots, you may have to remove and reinsert the USB ash drive to complete the update.
When updating the instrument rmware to 3.0.X and Option DPE is installed, do not cycle the instrument power until the Power-on diagnostic screen is cleared and the User interface is fully running. If the Instrument Fault LED is lit (red Power/Standby button), an additional instrument reboot is required. This may be performed by pressing the Power/Standby button. When the upgrade is complete, the Dolby rmware version will be 2.1.2.1. You can conrm the version on your instrument from the CONFIG > Utilities > SW Version menu.
4 WFM7200 Waveform Monitor v3.0.X Release Notes
Release notes
Incompatible operation
SNMP messages
Sweep
USB
Waveform mode cursor for
XYZ color space
When applying 3 signal formats, the unit indicates that the signal input is not standard. Applying unsupported video signals may result in a frozen PICT display.
Commands ret embedded audio channel pairs 9 & 10, 11 & 12, 13 & 14, and 15 & 16.
The waveform style must be set to Overlay to get 2 line or 2 eld sweep.
Always pre and remove the USB memory device from the USB port. You risk permanent loss of any les saved on the USB device if you do not use the “Unmount” feature.
If there are more than 32 les saved in a Capture or Pre sets directory on the USB device, you can only view the rst 32 les.
The voltage cursors are given in millivolt scale, but the XYZ color space is referenced in hex scale. To see the values for 000 to FFF, change the graticule settings to max and percent.
Gb/s signals to any instrument that does not support the
urning the audCurOutput OID return the string “Embed 7 & 8” for
ss the MAIN button and select USB Status to safely “Unmount”
Web browser
The Web browser applet will not resize when running in some versions of the Netscape browser and in some non-Windows Operating Systems (for example, Solaris).
We recommend using Java Runtime Engine (JRE) version 1.6 or above.
WFM7200 Waveform Monitor v3.0.X Release Notes 5
Loading...