Tektronix WFM200BA Instructions Manual

xx
WFM200BA Rechargeable Battery Pack
ZZZ
Instruct
ions
Battery Recycling
This WFM200BA Lithium-Ion rechargeable battery pack must be recycled or disposed of properly.
Lithium-Ion batteries are subject to disposal and recycling regulations and follow your applicable regulations before disposing of any batter Corporation (www.rbrc.org) for U.S.A. and Canada, or your local ba
Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles.
Place only discharged batteries in a battery collection container. Use electrical tape or other approved covering over the battery connection points to prevent short circuits.
Lithium-Ion Battery Transportation
The capacity of the Lithium-Ion rechargeable battery pack in this product is under 100 Wh. The lithium equivalent content has been shown to meet the applicable requirements as dened by the UN Manual of Tests and Criteria Part III Subsection 38.3.
Always check all applicable local, national, and internati battery.
Transporting an end-of-life, damaged, or recalled battery may, in certain cases, be specically limited or prohibited.
The battery pack must be adequately protected against short-circuit or damage during transport.
that vary by country and region. Always check
y. Contact Rechargeable Battery Recycling
ttery recycling organization.
This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling o of the Tektronix Web site (www.tektronix.com).
onal regulations before transporting a Lithium-Ion
ptions, check the Support/Service section
3. Secure the battery pack tab as shown below.
4. Replace the battery compartment cover:
a. Insert the
chassis slots as shown below.
three tabs on the battery cover into the
*P0751
075-1041-01
04101*
Safety Summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specied.
Retain product literature. Retain the original product
mation for future reference.
infor
id Fire or Personal Injury
Do not operate with suspected failures. If you suspect there
age to the battery, charger, or power supply, have it
is dam inspected by qualied service personnel.
Recharge battery pack properly. Recharge the battery pack
or the recommended charge cycle at the recommended
only f temperature.
Replace battery pack properly. Replace the battery pack only
he specied type and rating.
with t
oper battery charger. Use only the WFM2200 waveform
Use pr
monitor or the WFM200BC battery charger to charge the
00BA battery pack.
WFM2
t operate in wet/damp conditions.
Do no
Do not operate in an explosive atmosphere.
product surfaces clean and dry.
Keep
ty Terms in This Manual
Safe
CAUTION. These statements identify conditions or practices
could result in damage to the equipment or other
that property.
ty Symbols and Terms on the Product
Safe
DANGER indicates a n injury hazard imm ediately accessible as
ead the marking.
you r
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
Description
The WFM200 only with the Tektronix WFM2200 SD/HD/3G SDI Waveform Monitor & G of Lithium-Ion battery cells.
When the battery is installed, an internal circuit monitors the charge on the battery and reports the condition to either the WFM2200 waveform monitor or the WFM 200BC External Battery Charger.
When the battery is not installed, you can check the battery charge level by pressing the Check button on the back of the battery pack. LEDs illuminate to indicate the amount of charge in increments of approximately 20%.
Battery
NOTE. For optimum performance, charge the battery pack
complet storage.
The battery can be installed, removed, or replaced while the instrument is turned on and operating with the AC adapter.
1. On the rear panel of the instrument, remove the cover for the battery compartment:
a. Lift up the battery cover ring.
b. Turn the battery cover ring ¼ turn counterclockw ise.
c. Lift away the battery cover.
2. Insert the WFM200BA battery pack into the battery
compartment as shown below.
BA rechargeable battery pack is intended for use
enerator. The battery pack consists of an array
Pack Installation
ely before using it for the rst time or after prolonged
b. Close the battery cover and turn the battery cover ring
¼ turn clockwise to s ecure the cover.
c. Press th
e battery cover ring down so that it latches
into place as shown below.
Battery Maintenance Guidelines
The WFM200BA Lithium-Ion rechargeable battery pack requires routine maintenance and care in its use and handling. Be sure to use the following guidelines to safely use the WFM200BA Lithium-Ion batteries and achieve the maximum battery life span.
ry Pack Considerations
Batte
Do not leave a battery unused for an extended period of time,
r in the product or in storage. When a battery has been
eithe unused for six months, check the charge status, and charge or
se of the battery as appropriate. See Charging the Battery
dispo Pack and Battery Recycling.
The typical estimated life of a Lithium-Ion battery is about two to three years, or 300 to 500 charge cycles, whichever occurs rst. One charge cycle is a period of use from fully charged, to fully discharged, and fully recharged again. You should expect a two to three year life e xpectancy for batteries that do not run through complete charge cycles.
A rechargeable Lithium-Ion battery has a limited life and will gradually lose its capacity to hold a charge. T his loss of capacity (aging) is irreversible. As the battery loses capacity, the length of time it will power the product (run time) decreases.
ium-Ion battery continues to slowly discharge
ALith (self-discharge) when not in use or while in storage. You need
tinely check the charge status of the battery.
to rou
Use the WFM200BA battery pack only in WFM2200 waveform monitor. Use only WFM200BA battery packs in your WFM2200 waveform monitor.
x
Battery Pack Maintenance
Observe and note the run time that a new fully-charged battery provides for powering your product. You can use this new battery run time as a basis to compare run times for older batteries. The run time of your battery will vary depending on the product’s conguration and the applications that you run.
The battery pack gives the best performance when operated at normal room temperature, 20 °C ±5 °C (68 °F ±9 °F).
Routinely check the charge status of the battery.
Carefully monitor a battery that is approaching the end of its estimated life.
Consider replacing the battery with a new one if the battery run time drops below about 80% of the original run time, or the battery charge time increases signicantly.
Follow the storage requirements if you store or do not use a battery fo
r an extended period. If you do not follow the storage requirements, and the battery will not power the waveform mo
nitor when installed, consider the battery to be damaged. Do not connect power to the waveform monitor dur
ing this time. Remove the battery pack from the waveform monitor. Do not attempt to recharge or reuse the battery
. Replace it with a new battery.
Battery Pack Charging
The battery
pack charges automatically when the waveform monitor is connected to the external power supply. You can also charge
the battery pack with the Tektronix WFM200BC External Battery Charger. Remove the battery pack from the WFM200BC ch
arger when charging is complete.
A Lithium-Ion battery pack will self-discharge during non-use. To achieve the longest operating time, charge your battery pack before use. If you plan to store battery packs, read the instructions in the Battery Pack Storage section of this document.
When the battery pack is in the WFM2200 waveform monitor, the battery gauge (
) on the waveform monitor display
indicates the approximate amount of charge.
To avoid automatic shutdown of the battery pack, only run the wavefo
rm monitor on the battery pack when the gauge
on the waveform monitor is green or yellow.
Always verify the correct placement of the battery in the WFM2200 waveform monitor or the WFM200BC battery charger.
When the battery pack is installed in the waveform monitor, it will automatically charge whenever the supplied AC adapter is connected, whether the instrument is On, Off, or in Standby mode.
Conguration Typical charging time
One fully discharged battery pack
in the WFM2200 waveform
charging monitor with the waveform monitor turned on or off
One or two fully dischar ged battery packs charging in the WFM200BC external battery charger
5.5 hours
5.5 hours
CAUTION. To avoid damage to the battery pack, use only
the WFM2200 waveform monitor or the WFM200BC battery charger to charge the battery pack. Do not connect any other voltage source to the battery pack.
NOTE. For optimum performance, charge the battery pack
completely before using it for the rst time or after prolonged storage.
To discharge the battery pack completely, continue to run the waveform monitor on the battery pack until automatic shutdown occurs. After the instrument shuts down, either recharge the battery pack promptly or remove it from the instrument until you are ready to recharge the battery pack.
NOTE. To prolong the life of the battery pack and to prevent
shutdown, do not operate or charge the battery pack at high temperatures. For best results, allow the battery pack to cool to room temperature before using or charging the battery pack.
Do not leave a battery pack discharged for extended periods. See the Stor
ing Battery Packs section for information on how to
properly store a battery pack.
The battery
pack stops charging under the following conditions:
The battery pack is fully charged.
The internal temperature of the battery pack exceeds the safe charging threshold.
A fault cond
ition occurs.
The battery pack shuts down and disconnects itself from the WFM2200 waveform monitor under the following conditions:
The battery pack is fully discharged.
The interna
l temperature of the battery pack exceeds the
safe discharging threshold.
A fault condition occurs.
Battery Pa
ck Handling
Do not disassemble, crush, drop, or puncture the battery.
Do not short the external contacts on the battery.
Do not dispose of the battery in re or water.
Do not expo
se the battery to temperatures above +60 °C
(+140 °F).
Seek medical advice if a battery or part of it has been swallowed.
Do not put battery packs near heat or re. Do not put in sunlight.
Keep the ba
ttery pack clean and dry. Clean dirty
connectors with a dry, clean cloth.
Batteries contain hazardous chemicals that can cause burns or explode. If exposure to chemicals occurs, clean with soap and water and get medical aid. Repair the product before use if the battery leaks.
Do not attempt to open, modify, reform or repair a battery pack that appears to be malfunctioning, or which has been physically damaged.
Keep the battery away from children and animals.
Avoid exposing the battery to excessive shock or vibration.
Do not use a damaged battery or charger.
If a batte
ry pack has leaking uids, do not touch any
uids. Dispose of a leaking battery pack. See the
Battery R
ecycling section for information on disposal and
recycling.
In case of eye contact w ith uid, do not rub eyes. Immediately ush eyes thoroughly with water for at least 15 minutes, lifting upper and lower lids, until no evidence of the uid remains. Seek medical attention.
Battery Pack Storage
Store battery packs in a low-humidity environment free of corrosive gases. Storing battery packs in high-humidity environments, or outside the temperature range, can cause oxidation on the metallic parts, increased leakage, signicant aging and premature failure.
ot store b attery packs near heat or re. Do not store
Do n in the sunlight.
Do not keep battery packs in a place where the terminals can be shorted by metal objects (for example, coins, paper clips, or pens).
Do not remove a battery pack from its original packaging until required for use.
When possible remove the battery pack from the equipment when not in use.
Charge the battery to approximately 50% of capacity at least once every six months.
Remove the battery and store it separately from the instrument. Refer to the WFM2200 User Manual for instructions on removing and installing the battery.
For optimal battery life, store the battery at temperatures between +5 °C and +25 °C (+41 °F and +77 °F). Higher temperatures reduce the battery storage life.
Battery Pack Replacement
Use the instructions to remove and replace battery packs.
NOTE. Replace the Lithium-Ion battery pack only with a
WFM200BA battery pack.
See the Battery Recycling section for information on how to properly dispose of a Lithium-Ion battery pack.
Specications
Characteristic Description
Capacity, typical
Output, nominal 14.4 VDC
Charging temperature Installed in the WFM2200 waveform
Operating temperature Installed in the WFM2200 waveform
Storage temperature -20 °C to +60 °C (-4 °F to +140 °F)
Weight
6.14 Ah
monitor or WFM200BC battery charger: 10 °C to +40 °C (+50 °F to +104 °F); varies per the WFM2200 heat dissipation characteristics, the actual limit may be lower
monitor: 0 °C to +40 °C (+32 °F to +104 °F)
Battery: 453.6 g (16.0 oz)
Battery (including packaging): 567 g (20.0 oz)
Warranty Information
For warranty information, go to the www.tektronix.com Web site, and search for “WFM200BA warranty”.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to nd contacts in your area.