Tektronix VM700T, VM700A VMTX, VM700A VMTB Instructions Manual

Instructions
VMUPG Option Upgrades VM700T, VM700A VMTB, or VM700A VMTX Video Measurement Set
075-0294-07
Warning
www.tektronix.com
*P075029407*
075029407
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered tradem arks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your area.

Table of Contents

Service Safety Summary 1....................................
Kit Description 3............................................
VMUPG Software Option Upgrades 3.................................
VMUPG Hardware Option Upgrades 3.................................
Installation Instructions 7....................................
Firmware Option Upgrades 8........................................
Hardware Option Upgrades 12........................................
VMUPG 1S Upgrade 15.............................................
VMUPG 1S -- EMI 16...........................................
VMUPG 1S -- SDI 17............................................
VMUPG 2S 22.....................................................
VMUPG 2S -- EMI 23...........................................
VMUPG 2S -- SDI 34............................................
VMUPG 40 -- Option 40 Audio Measurements 36.........................
VMUPG 41 -- Option 41 Six-Input Audio 39.............................
VMUPG 48 -- Option 48 GPIB interface 42..............................
VMUPG 3D -- Option 40 to Option 41 Conversion 44......................
Install the New Option Key 47........................................
Verify the Installation 50.............................................
VMUPG Option Upgrades
i
Table of Contents

List of Figures

Figure 1: Cover panels and circuit board retainer bar removal 13....
Figure 2: Right card cage retainer plate removal 14................
Figure 3: SDI panel and cable positionin g 17.....................
Figure 4: SDI circuit board location 18..........................
Figure 5: SIMM installation and R32 location
(VM700T SN B020100 and B029999) 19......................
Figure 6: Acquisition board Installation 20.......................
Figure 7: Right side EMI bracket installation 24..................
Figure 8: Location of the EMI clip on the CPU I/O b oard 25........
Figure 9: Clamp-on ferrite bead position
(not for 119-4258-XX power supplies) 26......................
Figure 10: EMI Brackets and EMI gasket shield installation 27......
Figure 11: Rear panel screw removal
(VM700A with VMTB/VMTX) 29...........................
Figure 12: EMI gaskets and EMI fan filter installation
(VM700A with VMTB/VMTX) 30...........................
Figure 13: EMI Fan Filter location
(VM700T -- SN B029999 & below) 33.........................
Figure 14: Locating the audio option boards
in the left-side card cage 38.................................
Figure 15: Locating the audio option boards
in the left-side card cage 40................................
Figure 16: Locating the circuit boards in the left-side card cage 43...
Figure 17: Locating the audio option boards
in the left-side card cage 45.................................
Figure 18: Audio Analog circuit board showing the location
of the Input Selector circuit board (shaded) 46.................
Figure 19: Typical main configure menu 47.......................
Figure 20: Option key control menu 48..........................
Figure 21: Error message for invalid option key 49................
Figure 22: Option identification label 52.........................
Figure 23: Measurement set rear panel showing the
option label location 52....................................
ii
VMUPG Option Upgrades

List of Tables

Table of Contents
Table 1: Check list for VMUPG 1S option upgrade 16..............
Table 2: Check list for VMUPG 2S option upgrade 23..............
T able 3: Screw sizes and types used in the rear panel installation 29.
VMUPG Option Upgrades
iii
Table of Contents
iv
VMUPG Option Upgrades

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
VMUPG Option Upgrades
1
Service Safety Summary
2
VMUPG Option Upgrades

Kit Description

This kit includes instructions for VMUPG software and hardware upgrades. Only those parts needed to install the options are provided in this kit. Parts are also provided to preserve EMI suppression.

VMUPG Software Option Upgrades

These instructions are for adding any one or a combination of the following firmware option upgrades to the VM700T Video Measurement Set or the VM700A Video Measurement Set with the VMTB or VMTX Turbo upgrade installed. See page 8 for firmware option installation instructions.
These instructions support Tektronix modification M89159, for firmware upgrade to archive number 000815.
H VMUPG 1G 2T Echo and Rounding of Black and White Measurements
H VMUPG 3B Dual Standard (Option 01 NTSC and Option 11 PAL)
H VMUPG 20 Teletext Measurements
H VMUPG 21 Camera Measurements
H VMUPG 22 Video Wander Measurements
H VMUPG 30 Component Measurements
H VMUPG 42 Audio/Video Timing Measurements
(requires either Option 40 or Option 41)
Products. The VMUPG firmware option upgrades can be installed in the following products:
VM700T VM700A with VMTB or VMTX installed

VMUPG Hardware Option Upgrades

These instructions are for adding any one or a combination of the following hardware option upgrades to the VM700T Video Measurement Set or the VM700A Video Measurement Set with the VMTB or VMTX Turbo upgrade installed.
VMUPG Option Upgrades
3
Kit Description
VMUPG 1S-
Option 1S Serial Digital
Interface
VMUPG 2S-
Option 1S Serial Digital
Interface
VMUPG 40-
Option 40 Audio
Measurements
This kit includes: SDI and an SDI Interface Panel circuit board with installation instructions and a short verification procedure. In addition, one SIMM is replaced on the Acquisition (A18) circuit board and one Boot ROM is replaced on the CPU board. See page 15 for installation instructions.
Products. The VMUPG 1S upgrade can be installed in the following products.
VM700T SN B020100 and Above
This kit includes: SDI, SDI Interface Panel and Acquisition (A18) circuit boards with installation instructions and a short verification procedure. See page 22 for installation instructions.
Products. The VMUPG 2S upgrade can be installed in the following products.
VM700T SN B019999 and Below VM700A with VMTB or VMTX installed
This kit includes: Audio Analog (A13) and Audio Processor (A12) circuit boards and the installation instructions with a short verification procedure. In addition, two mini-XLR connectors are provided to allow the user to adapt existing cabling to the connection method used for Option 40. Refer to the VM700T Option 40/41/42 User Manual, provided with this kit, for connector pin assignments. See page 36 for installation instructions.
VMUPG 41-
Option 41 Six-Input Audio
4
Products. The VMUPG 40 upgrade can be installed in the following products.
VM700T VM700A with VMTB or VMTX
This kit includes: Six-Input Audio Analog (A17) and Audio Processor (A12) circuit boards. A 37-pin connector is provided to allow you to adapt existing cabling to the connection method used for Option 41. Refer to the VM700T Option 40/41/42 User Manual, provided with this kit, for connector pin assignments and installation instructions for the connector and ferrite EMI core. See page 39 installation instructions.
Products. The VMUPG 41 upgrade can be installed in the following products.
VM700T VM700A with VMTB or VMTX
VMUPG Option Upgrades
Kit Description
VMUPG 48-
Option 48 GPIB Interface
VMUPG 3D-
Option 40 to Option 41
Conversion
This kit includes a GPIB circuit board. See page 42 for installation instructions.
Products. The VMUPG 48 option upgrade can be installed in the following products.
VM700T VM700A with VMTB or VMTX
This kit includes a 6-Input Selector circuit board to convert an installed Audio Option 40 with two input channels to Audio Option 41 operation with six input channels. These instructions provide the installation instructions and a short verification procedure. See page 44 for installation instructions.
A 37-pin connector is provided to allow you to adapt existing cabling to the connection method used for Option 41. Refer to the VM700T Option 40/41/42 User Manual, provided with this kit, for connector pin assignments and installation instructions for the connector and ferrite EMI core.
Products. The VMUPG 3D option upgrade can be installed in the following products.
VM700T Option 40 VM700A with VMTB or VMTX with Option 40
VMUPG Option Upgrades
5
Kit Description
6
VMUPG Option Upgrades

Installation Instructions

This section provides information on how to install software and hardware options to the VM700T Video Measurement Set or the VM700A Video Measurement Set with the VMTB or VMTX Turbo upgrade installed. This section covers the following topics:
H Installing firmware option upgrades page 8
H Installing hardware option upgrades:
VMUPG 1S page 15 VMUPG 2S page 22 VMUPG 40 page 36 VMUPG 41 page 39 VMUPG 48 page 42 VMUPG 3D page 44
H Installing the new option key page 47
H Verifying installation page 50
VMUPG Option Upgrades
7
Installation Instructions

Firmware Option Upgrades

NOTE. The option hardware must be installed first for those options to be checked in the Installation Verification procedure by the power-on diagnostics.
This field-installable VMUPG Options Firmware upgrade kit adds the measure­ment capabilities of any options ordered as part of this installation, and upgrades the firmware to the most current version in compatible VM700T instruments. A user manual is included for any added option.
Kit Parts List
The following parts list is for the VMUPG firmware option upgrades.
Circuit/figure number
Quantity Part number Description
1EA 075-0294-07 INSTRUCTIONS: KIT OPTION UPGRADES;
VMUPG
1EA 063-2913-04 FLOPPY DISK SET; DRIVER, VM700T SINGLE
IMAGE
1EA 334-9282-XX MARKER, IDENT REAR PANEL OPTION
LABEL, 3.50 X 0.50, 0.10 POLY
1EA -- -- -- -- -- -- -- -- -- -- DATA SHEET; SOFTWARE KEY INFORMATION
OPTION USER MANUALS
1EA 070-9648-XX* MANUAL,TECH:USER,VM700T OPT 01 NTSC
MEASUREMENTS (FOR OPTION 3B)
1EA 070-9649-XX* MANUAL,TECH:USER,VM700T OPT 11 PAL
MEASUREMENTS (FOR OPTION 3B)
1EA 070-9651-XX* MANUAL,TECH:USER,VM700T OPT 1G 2T
ECHO AND ROUNDING OF BLACK AND WHITE MEASUREMENTS
1EA 070-9652-XX* MANUAL,TECH:USER,VM700T OPT 20
TELETEXT MEASUREMENTS
1EA 070-9900-XX* MANUAL,TECH:USER,VM700T OPT 21
CAMERA MEASUREMENTS
1EA 071-0038-XX* MANUAL,TECH:USER,VM700T OPT 22 VIDEO
WANDER MEASUREMENTS
1EA 070-9654-XX* MANUAL,TECH:USER,VM700T OPT 30
COMPONENT MEASUREMENTS
1EA 070-9656-XX* MANUAL,TECH:USER,VM700T OPT 40/41/42
AUDIO OPTIONS
* Supplied with the ordered option.
8
VMUPG Option Upgrades
Installation Instructions
NOTE. The Laplink
(174-3800-XX) is an optional accessory and not supplied with
the kit. The Laplink must be ordered separately.
When you receive your upgrade kit(s) for your VM700T, VM700A VMTB or VM700A VMTX Video Measurement set you will receive only one option key. The new option key is a unique alpha-numeric number that is used to activate the authorized options for a specific measurement set. It is based on the currently installed options plus the new option(s) being added or deleted for the upgrade. Previously installed option firmware is upgraded to the latest version compatible with the VM700T Video Measurement Set.
Continue with these instructions if you are installing one or more of the firmware only options that do not require additional hardware to be installed. If you are installing any of the hardware options (Option 1S, Option 40, Option 41, Option 48, or Option 3D) as part of this upgrade, follow the instructions provided with those option upgrade kits.
These instructions are for personnel familiar with the VM700T Video Measure­ment Set. For further assistance call your nearest Tektronix, Inc., Service Center or Tektronix Factory Service.
VMUPG Option Upgrades
9
Installation Instructions
Install the Firmware
Upgrade
The firmware upgrade is performed using the floppy disks supplied with this kit. The installation program on the floppy disks copies the firmware-upgrade software to your PC. You will upgrade your measurement set using the installed software on your PC hard drive. Complete instructions for performing the firmware upgrade are included in the installation program.
The minimum PC hardware and operating system requirements for performing the firmware upgrade are listed below:
Hardware requirements
12 MB of free disk space on hard drive MS/DOS (5.0 or later), Windows 3.1, or Windows
386 microprocessor or better
3.5 in. floppy disk drive
LapLink parallel cable (Tektronix part number 174-3800-00)
1
The installation program will not run under Windows NT.
Operating system requirements
95/98
1
Load the Firmware
Upgrade Software
To load the firmware-upgrade software on your PC, perform the following procedure:
1. Insert the provided Program Disk into a floppy disk drive on your PC.
NOTE. The installation program defaults to an installation source of drive A: and a destination of drive C:. You will be prompted by the installation program to verify or change the source and destination drives as required by your system.
2. Install the upgrade software using one of the following command lines:
H From Windows 3.1 or MS/DOS
run INSTALL.BAT
H From Windows 95/98
run INSTALL.95
3. Follow the screen prompts to complete the loading of the software for the
firmware upgrade.
10
VMUPG Option Upgrades
Installation Instructions
Upgrade Your
Measurement Set
Once you have installed the firmware-upgrade software on your PC, you can upgrade multiple VM700T or Turbo VM700A measurement sets without having to reload the floppy disks. To upgrade the firmware of a VM700T or Turbo VM700A measurement set from your PC, perform the following procedure:
CAUTION. To avoid loading incorrect firmware into your measurement set, be sure to use the correct firmware-image archive number for the instrument firmware you want to install. If you have installed multiple firmware images, you will have more than one firmware-image directory. If you load the wrong firmware, repeat the firmware upgrade using the correct firmware version.
The firmware-upgrade installation program creates a directory under the VM_UPGRD directory using the current firmware-image archive number loaded on the floppy disk set. The firmware-image number is based on a date using a format of year, month, and day. In most situations, you will want to load the latest version of the firmware into your measurement set.
NOTE. Do not perform this upgrade if your firmware image number is 030930 or higher.
1. If your firmware image number is lower than 030930, change the working
directory on your PC to the following firmware-image directory:
<destination drive>\VM_UPGRD\F_<archive number>
For example, if you load the firmware-upgrade software to a destination
drive of C:\ and your firmware archive number is 000815, then your
command-line directory should look like the following:
C:\VM_UPGRD\F_000815
2. Connect the LapLink cable between the PC and the measurement set.
NOTE. To perform the firmware upgrade on multiple measurement sets, you will need to run the BURN.BAT program on each individual instrument.
3. Windows 3.1 or MS/DOS only. To perform the firmware upgrade,
run BURN.BAT and follow the prompts.
4. Windows 95/98 only. To perform the firmware upgrade, run BURN.BAT
from Windows Explorer and follow the prompts.
After Installing the Firmware. After installing the firmware upgrades go to Install the New Option Key refer to page 47.
VMUPG Option Upgrades
11
Installation Instructions

Hardware Option Upgrades

CAUTION. To prevent static discharge damage, service the measurement set only at an antistatic work station. Observe standard handling precautions for static-sensitive devices while installing this kit. Always wear a grounded wrist strap, grounded foot strap, and static resistant apparel while installing this kit.
These instructions are for personnel familiar with servicing. If you need further details for disassembling or reassembling the measurement set, refer to the product service manual. For further assistance call your nearest Tektronix, Inc., Service Center or Tektronix Factory Service.
Tools Required
Instrument Preparation
The following tools are required to install the option upgrades.
H Pozidriv screwdriver, P2
H Torx screwdriver, T20
H Soldering iron, 15W or less, fine tip or SMD soldering iron
The following information prepares your instrument for hardware option upgrades.
WARNING. Dangerous shock hazards may be exposed when the measurement set covers are removed. Before proceeding, ensure that both power switches are in the off position (see Figures 1 and 2), and then disconnect the measurement set from the power source.
NOTE. The following instructions are for general reference. Check your option upgrade section for specific cover panel removal instructions.
Cover Panels. The four cover panels are positioned with slotted corner extrusions and fastened with screws to the instrument rear panel. Removing each cover panel requires removing its fastening screws on the rear panel and sliding the panel toward the rear of the instrument and out of the grooves in the chassis frame. Replacing each cover panel is the reverse of the removal procedure.
12
1. Remove the screws from the edge of the cover panels. See Figure 1.
VMUPG Option Upgrades
Loading...
+ 40 hidden pages