This document applies to TLA System Software
version 5.1.
Warning
These servicing instructions are for use by
qualified personnel only. To avoid personal injury,
do not perform any servicing unless you are
qualified to do so. Refer to all safety summaries
prior to performing service.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price c hange privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
HIn North America, call 1-800-833-9200.
HWorldwide, visit www.tektronix.com to find contacts in your area.
Warranty 6
Tektronix warrants that the parts and modules (“parts”) that it manufactures and sells will be free from defects in
materials and workmanship for a period of three (3) months from the date of shipment. If any such part proves
defective during this warranty period, Tektronix, at its option, either will repair the defective part without charge,
or will provide a replacement in exchange for the defective part. Parts and modules used by Tektronix for
warranty work may be new or reconditioned to like new performance. All replaced parts and m odules become the
property of Tektronix.
In order to obtain service under this warranty, Custom er must notify Tektronix of the defect before the expiration
of the warranty period and make suitable arrangements for the performance of service. Customer shall be
responsible for packaging and shipping the defective part to the service center designated by Tektronix, with
shipping charges prepaid. Tektronix shall pay for the return of the part to Customer if the shipment is to a location
within the country in which the Tektronix service center is located. Customer shall be responsible for payi ng all
shipping charges, duties, taxes, and any other charges for parts returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage
resulting from attempts by personnel other than Tektronix representatives to install, repair or service the part; b) to
repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or
malfunction caused by the use of non-Tektronix supplies; or d) to service a part that has been modified or
integrated with other products or parts when the effect of such modification or integration increases the time or
difficulty of servicing the part.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PART IN LIEU OF ANY OTHER
WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’
RESPONSIBILITY TO REP AIR OR REPLACE DEFECTIVE PARTS IS THE SOLE AND EXCLUSIVE
REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS W ARRANTY. TEKTRONIX AND ITS
VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADV ANCE NOTICE OF
THE POSSIBILITY OF SUCH DAMAGES.
Warranty 9(b)
Tektronix warrants that the media on which this software product is furnished and the encoding of the programs on
the media will be free from defects in materials and workmanship for a period of three (3) months from the date of
shipment. If any such medium or encoding proves defective during the warranty period, Tektronix will provide a
replacement in exchange for the defective medium. Except as to the media on which this software product is
furnished, this software product is provided “as is” without warranty of any kind, either express or implied.
Tektronix does not warrant that the functions contained in this software product will meet Customer’s
requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Custom er must notify Tektronix of the defect before the expiration
of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and
workmanship within a reasonable time thereafter, Customer may terminate the license for this software product
and return this software product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY
OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
TEKTRONIX’ RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S
PA YMENT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF
THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT,
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX
OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table of Contents
TLA5KUP Option 10
General Safety Summaryv...................................
Service Safety Summaryvii....................................
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to
this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system.
Read the safety sections of the other component manuals for warnings and
cautions related to operating the system.
ToAvoidFireor
Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and
certified for the country of use.
Connect and Disconnect Properly. Do not connect or disconnect probes or test
leads while they are connected to a voltage source.
Ground the Product. This product is grounded through the grounding conductor
of the power cord. To avoid electric shock, the grounding conductor must be
connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings
and markings on the product. Consult the product manual for further ratings
information before making connections to the product.
The inputs are not rated for connection to mains or Category II, III, or IV
circuits.
Connect the probe reference lead to earth ground only.
Power Disconnect. The power cord disconnects the product from the power
source. Do not block the power cord; it must remain accessible to the user at all
times.
Do Not Operate Without Covers. Do not operate this product with covers or panels
removed.
Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
Avoid Exposed Circuitry. Do not touch exposed connections and components
when power is present.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
v
General Safety Summary
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
Terms in this Manual
Symbols and Terms
on the Product
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
These terms may appear on the product:
HDANGER indicates an injury hazard immediately accessible as you read the
marking.
HWARNING indicates an injury hazard not immediately accessible as you
read the marking.
HCAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
CAUTION
Refer to Manual
Mains Disconnected
OFF (Power)
vi
WARNING
High Voltage
Mains Connected
ON (Power)
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
Protective Ground
(Earth) Terminal
Standby
Earth Terminal
Chassis Ground
Service Safety Summary
Only qualified personnel should perform service procedures. Read this Service
Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is
present.
Disconnect Power. To avoid electric shock, disconnect the main power by means
of the power cord or, if provided, the power switch.
Use Care When Servicing With Power On. Dangerous voltages or currents may
exist in this product. Disconnect power, remove battery (if applicable), and
disconnect test leads before removing protective panels, soldering, or replacing
components.
To avoid electric shock, do not touch exposed connections.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
vii
Service Safety Summary
viii
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
Preface
This instruction manual contains specific information about the TLA5KUP logic
analyzer field upgrades. The logic analyzer field upgrades consist of software
and hardware options for the TLA5000B and TLA5000 Series Logic Analyzers.
NOTE. Unless otherwise noted all references to TLA5000 Series Logic Analyzers
apply to both TLA5000B and TLA5000 instruments.
Products Eligible for TLA5KUP Upgrades
Table i lists all of the TLA5000 Series Logic Analyzers eligible for upgrades via
the TLA5KUP field upgrade kits. Review Table i to determine if your logic
analyzer is eligible for an upgrade and then use Table ii on page x, to explore
possible upgrade paths.
Table i: TLA5000 Series logic analyzers eligible for upgrades
The TLA5KUP upgrade kits are designed for “One TLA5KUP upgrade kit per
TLA5000 mainframe.” If you want to upgrade multiple mainframes, you must
order one TLA5KUP upgrade kit with the appropriate options for each mainframe.
The latest TLA Application Software has been tested and can be installed and
will be supported by Tektronix only on the Tektronix-supplied version of
Microsoft Windows XP Professional.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
ix
Preface
upgradingtothelatestTLAAp
pgy
L
ASW
V
W
L
A
h
igh
TLA5000StdwithTLASWV4.4
Windows2000
TLA5KUPOption41
p
f
datafromTDSoscilloscope
s
f
SoftwareandMicrosoftWindows
Table ii: TLA5KUP Logic Analyzer Field Upgrade Matrix
New capability desiredCurrent configuration and
TLA software version
Add New Software Features
Add new functionality to existing
TLA5000 logic analyzers by
plication Software.
Microsoft Windows XP Professional operating system is recommendedfor TLASWV5.0or
er.
Add more DRAM
Increase controller memory from
512 MB to 1 GB.
Add more DRAM
Increase controller memory from
512 MB to 1 GB.
Add DVD-ROM/CD-RW Drive
Add DVD-ROM/CD-RW Drive to
back up or transfer user and data
files.
Add New iView External Oscilloscope Capability
Add new iView capability to view
data
rom TDS oscilloscopes
correlated directly on the TLA5000
logic analyzer
Enhance your current TLA5000
logic analyzer by increasing state
speed or record length. Run the
PowerFlex Utility to inform you
what upgrades are available.
Instructions to obtain an upgrade
are provided.
1
.
TLA5000 Std with TLA SW V5.1Microsoft
-
TLA5000 Std with TLA SW V5.0Microsoft
TLA5000 Std with T
or V4.3
Any TLA5000 mainframe--TLA5KUP Option 10
Any TLA5000B mainframe--TLA5KUP Option 11
TLA5000 Std with TLA SW V5.1 or
V5.0
TLA5000 Std with TLA SW V4.4
or V4.3
TLA5000 Std with TLA SW V5.1Microsoft
TLA5000 Std with TLA SW V5.0
TLA5000 Std with TLA SW V4.4
or V4.3
Any TLA5000 series logic
analyzer with TLA SW V4.3 and
above
Add Wheeled Transport CaseAny TLA5000 mainframe--016-1522-xx
1
For a list of supported TDS oscilloscopes, please visit our website at www.tektronix.com/la.
Current configuration and
TLA software version
operating
system
(Same as used with TDS6000 and
TDS7000 instruments)
Service and Upgrade Notes
To prevent personal injury or damage to the instrument, consider the following
requirements before attempting service:
HRead the General Safety Summary and Service Safety Summary found at the
beginning of this manual.
HOnly qualified service personnel should perform the procedures in this
manual.
Be sure to follow all warnings, cautions and notes.
Adjustment and Certification Interval
Generally, you should perform the adjustments and performance verification
procedures described in the TLA5000 Logic Analyzer Series Service Manual
(Tektronix part number, 071-1305-xx) once per year, or following repairs that
may affect adjustment or calibration.
Service Offerings
Tektronix provides service to cover repair under warranty as well as other
services that are designed to meet your specific service needs.
Whether providing warranty repair service or any of the other services listed
below, Tektronix service technicians are equipped to service your logic analyzer.
Services are provided at Tektronix Services Centers.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
xi
Preface
Warranty Repair Service
Calibration and Repair
Service
The warranty for this product is located behind the title page in this manual.
Tektronix technicians provide warranty service at most Tektronix service
locations worldwide. The Tektronix product catalog lists all service locations
worldwide, or you can visit us on our Customer Services World Center Web site
at:
Tektronix.com/Measurement/Service
In addition to warranty repair, Tektronix Service offers calibration and other
services which provide solutions to your service needs and quality standards
compliance requirements.
The following services can be tailored to fit your requirements for calibration
and/or repair of your logic analyzer.
Service Options. Tektronix service options can be selected at the time you
purchase your instrument. You select these options to provide the services that
best meet your service needs.
Service Agreements. If service options are not added to the instrument purchase,
then service agreements are available on an annual basis to provide calibration
services or post-warranty repair coverage. Service agreements may be customized to meet special turn-around time and/or on-site requirements.
Service on Demand. Tektronix offers calibration and repair services on a
“per-incident” basis that is available with standard prices.
Self Service. Tektronix supports repair to the replaceable-part level by providing
for circuit board exchange.
Use this service to reduce down-time for repair by exchanging circuit boards for
remanufactured ones. Tektronix ships updated and tested exchange boards. Each
board comes with a 90-day service warranty.
For More Information. Contact your local Tektronix service center or sales
engineer for more information on any of the Calibration and Repair Services just
described.
xii
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
TLA5KUP Option 10
TLA5KUP Option 10:Memory Upgrade Installation
TLA5KUP option 10 provides the capability of upgrading the memory on your
TLA5000 Series Logic Analyzer to 1 GB.
NOTE. These instructions apply to TLA5000 Series Logic Analyzers only. To
upgrade the memory on the TLA5000B Series Logic Analyzers, please order
TLA5KUP option 11.
Instruments
TLA5000 Series Logic AnalyzersAll Serial Numbers
Parts List
Table 1--1: TLA5KUP Option 10 parts list
QuantityPart numberDescription
1ea156-9442-xx512 MB DIMM
1eaN/ATLA5KUP kit label
Minimum Tool and Equipment List
Table 1--2: Tools required for installing upgrade
Item
no.
1Screwdriver handle
2T-15 Torx tipUsed for removing most the instru-
NameDescription
Accepts TorxR-driver bits
ment’s screws. TorxR-driver bit for
T-15 size screw heads
General tool
number
620-440
640-247
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
1--1
TLA5KUP Option 10: TLA5000 Memory Upgrade
Installation Prerequisites
These instructions assume that you are familiar with servicing the instrument. If
you need further details for disassembling or reassembling the instrument, refer
to the TLA5000 Logic Analyzer Series Service Manual (071-1305-xx). You may
also contact your nearest Tektronix, Inc., Service Center or Tektronix Factory
Service Center for installation assistance.
Be sure to observe the following precautions to avoid damaging the logic
analyzer while preparing to service it.
CAUTION. Many components within the instrument are susceptible to static-discharge damage.
Service only in a static-free environment. Observe standard handling precautions
for static-sensitive devices.
Always wear a grounded wrist strap, grounded foot strap, and static-resistant
apparel while installing this kit.
WARNING. Dangerous voltages may be present. Before performing any procedure
in this subsection, disconnect the power cord from the line voltage source.
Failure to do so could cause serious injury or death.
HDo not handle static-sensitive components on boards.
HTransport and store static-sensitive boards in their original containers or on
conductive foam. Label any package that contains static-sensitive assemblies.
HWear anti-static wrist strap while handling the boards to discharge the static
voltage from your body.
HDo not allow anything capable of holding or generating a static charge on
the work surface.
HAvoid handling boards in areas that have a floor or work surface cover that
is capable of generating a static charge.
Remove the Accessories Pouch
Remove the accessories pouch to access the covers on the instrument.
1--2
1. Turn the logic analyzer off.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
2. Remove the power cord and all probes.
3. Open the pouch and locate the two snaps on the inside front side of the
pouch.
4. Gently pull on each of the two tabs to unsnap the front of the pouch.
5. At the rear of the instrument, peel off the Velcro that holds the pouch to the
instrument.
6. Set the pouch aside.
7. To reinstall the pouch, perform these steps in reverse order. Tighten the T-15
Torx-drive screws to 8-in lbs.
Remove the Trim and Covers
Remove the trim and covers as shown in Figure 1--1 on page 1--4, by following
this procedure.
TLA5KUP Option 10: TLA5000 Memory Upgrade
1. Remove the top cover trim.
a. Remove the two T-15 Torx-drive screws that secure the top cover trim to
the instrument.
b. Remove the snap studs from the top cover.
c. Slide the trim panel toward the rear of the instrument allowing the tabs to
clear the cover openings, then pull out to remove the panel from the
instrument (you may need to loosen the two top black feet on the back of
the instrument if the cover does not come off easily).
2. Remove the right side trim.
NOTE. When you remove the CD Drive trim, notice the notches in the trim that
provide the clearance for the chassis screws located under the trim. When you
replace the trim, make sure that you orient the trim with the notches in the
correct location. Otherwise the trim may not fit properly.
a. Remove the Drive trim by inserting a flat blade screwdriver in the
bottom slot of the trim and gently prying the trim piece out of the side
panel. Pull the trim up and out from the instrument.
b. Remove the two T-15 Torx-drive screws that secure the right side trim to
the bottom of the instrument.
c. Slide the trim panel toward the rear of the instrument allowing the tabs to
clear the cover openings, then pull the panel from the instrument.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
1--3
TLA5KUP Option 10: TLA5000 Memory Upgrade
Accessory
pouch
Top cover trim
Figure 1--1: Trim and covers
Right side
panel
CD-drive trim
T-15 Torx-drive
screws (2)
1--4
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
Remove the Right-Side Cover
Remove the right-side cover to access most of the internal components of the
instrument. Refer to Figure 1--2 while removing the right-side cover.
NOTE. All mounting screw holes are indicated by a star etched around the
mounting hole.
1. Remove the 15 T-15 Torx-drive screws that secure the cover to the top and
right sides of the chassis.
2. Remove the cover.
CAUTION. Take care not to bind or snag the covers on the internal cabling as you
remove or install.
TLA5KUP Option 10: TLA5000 Memory Upgrade
Figure 1--2: Right-side cover removal
Tab
Right side cover
T-15 Torx-drive
screws (14)
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual
1--5
TLA5KUP Option 10: TLA5000 Memory Upgrade
Adding Memory
The memory sockets are located on the processor board mounted to the back
panel (refer to Figure 1--3).
1. Install the memory module as follows:
a. For TLA5000 instruments with serial numbers B010000 to B019999,
install the memory module in the single, spare socket.
b. For TLA5000 instruments with serial numbers B020000 or higher, install
the memory module in one of the spare sockets. For optimum performance, leave one socket empty between the original and new DIMMs
(the correct socket for the new memory module is labeled Channel B
DIMM 0).
Memory module (s)
Battery
Verifying Operation
1--6
Figure 1--3: Memory module and battery location
2. Reinstall the trim, covers, and the accessories pouch.
To verify the proper operation of the logic analyzer, follow these steps:
1. Plug the power cord in and turn the logic analyzer on.
TLA5KUP Logic Analyzer Field Upgrade Kit Instruction Manual