Tektronix TLA5201B, TLA5202B, TLA5203B, TLA5204B Installation Manual

xx
TLA5000B Series
ZZZ
Logic Analyzer
Installation Manual
This document supports TLA System Software Version 5.6 and above.
Warning
www.tektronix.com
077-2066-02
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Tektronix, Tek, MagniVu, and iView are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O . Bo x 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. World wide, vi s it www.tektronix.com to nd contacts in your area.
Warranty 2
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective p roduct without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be n the property of Tektronix.
ew or reconditioned to like new performance. All replaced parts, modules and products become
In order to o the warranty period and make suitable a rrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage result b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modied or integrated with other products when the effect of such modication or integration increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
TRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE
TEK AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
btain service under this warranty, Customer must notify Tektronix of the defect before the expiration of
ing from attempts by personnel other than Tektronix representatives to install, repair or service the product;
Warranty 9(b)
Tektronix warrants that the media on which this software product is furnished and the encoding of the programs on the media will be free from defects in materials and workmanship for a period of three (3) months from the date of shipment. If any such medium or encoding proves defective during the warranty period, Tektronix will provide a replacement in exchange for the defective medium. Except as to the media on which this software product is furnished, Tektronix does not warrant that the functions contained in this software product will meet Customer’s requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF M ERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRO PAYMENT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
this software product is provided “as is” without warranty of any kind, either express or implied.
NIX’ RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S
Table of Contents
Service Safety Summary................ .................................. ................................ ........ iii
Preface .............................................................................................................. iv
TLA5000B Series Logic Analyzers ............ .................................. .......................... iv
Documentation................................................................................................. v
Basic Installation ................................................................................................... 1
Check the Shipping List.................................. ................................ ..................... 1
Site Considerations ............................................................................................ 1
Chassis Ground Connections .................... ................................ ............................. 3
Connecting Accessories............ ................................ ................................ ........... 4
Connecting Probes............................................................................................. 5
First Time Operation ......................... .................................. ............................... 6
Creating Operating System Restore Discs ................... .................................. ............. 8
Performing the Incoming Inspection ............. .................................. ......................... 9
Backing Up User Files ......... .................................. ................................ ............. 9
Connecting Probes to the Target System .................................................................... 9
Additional Information............. ................................ ................................ ........... 9
Product Overview ................................................................................................. 11
Front Panel Controls........................................ ................................ .................. 11
External Connectors ................ .................................. ................................ ........ 11
Restoring and Installing Software . .. . ... ... . .. . ... ... ... . .. . ... ... ... . .. . ... ... ... . .. . ... ... ... . .. . ... ... ... . .. . 13
Restoring the Instrument Operating System ............. ................................ .................. 13
Change the BIOS Settings .. . .. . .. . .. . ... ... ... ... ... ... . .. . .. . .. . .. . .. . ... ... ... ... ... ... . .. . .. . .. . .. . .. . ... 16
Reinstalling the TLA Application Software . . ... ... . .. . ... ... ... . .. . ... ... ... . .. . ... ... . .. . ... ... ... . .. . .. 16
Upgrading or Restoring Firmware .................. ................................ ........................ 19
Appendix A: User Service Procedures .......................................................................... 21
General Care .................................................................................................. 21
Self Calibration ....................... ................................ ................................ ........ 21
Preventive Maintenance.............................. .................................. ...................... 21
In Case of Problems .................... ................................ ................................ ...... 22
Repacking for Shipmen
Appendix B: Accessories and Options ........ .................................. ................................ 27
Standard Accessories......................................................................................... 27
Optional Accessories ......................................................................................... 27
Options......................................................................................................... 27
Index
t ............................. ................................ ........................ 25
TLA5000B Series Logic Analyzer Installation Manual i
Table of Contents
List of Figure
Figure i: TLA5000B series logic analyzer.......................... ................................ ............. v
Figure 1: Lo
Figure 2: Accessory connections .......... ................................ ................................ ....... 4
Figure 3: Connecting the P64xx logic analyzer probes ............................. ........................... 6
Figure 4: Power cord connector location . ................................ .................................. ..... 7
Figure 5: Logic analyzer front panel ............................................................................ 11
List of T
Table 1: Environmental characteristics ......... .................................. ............................... 1
Table 2
Table 3: Accessory connection information..................................................................... 5
Table 4: Failure symptoms and possible causes...................................... .......................... 24
cation of the ground connection........................... .................................. ....... 3
ables
: Power considerations .................................................................................... 2
s
ii TLA5000B Series Logic Analyzer Installation Manual
Service Safety Summary
Only qualied personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures. Analyzer Family Product Safety & Compliance Instructions (Tektronix part number 071-2591-xx).
Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering rst aid and resuscitation is present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
UseCareWhenServicingWithPowerOn. Dangerousvoltagesorcurrentsmay exist i disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
The General Safety Summary can be found in the Tektronix Logic
n t his product. Disconnect power, remove battery (if applicable), and
TLA5000B Series Logic Analyzer Installation Manual iii
Preface
Preface
This manual c analyzer and related accessories.
To prevent p starting service:
The proced personnel.
Read the Ge
Tektronix Logic Analyzer Family Product Safety & Compliance Instructions
(Tektronix part number 071-2591-xx).
Be sure to follow all warnings, cautions, and notes in this manual.
ersonal injury or damage, consider the following requirements before
TLA5000B Series Logic Analyzers
The TLA5000B series logic analyzers consist of portable logic analyzer mainframes, which differ by channel width, and all of the accessories and supports that are used with them. The logic analyzers are built on the Microsoft Windows operating system, which allows you to install any PC-compatible, third-party hardware and software on the instrument.
Because the instrument can operate in a network environment, Microsoft recommends the following:
ontains all information needed to install your Tektronix logic
ures in this manual should be performed only by qualied service
neral Safety Summary and Service Safety Summary found in the
Use an Internet rewall.
Install operating system updates regularly.
Use up-to-date antivirus software.
iv TLA5000B Series Logic Analyzer Installation Manual
Documentation
Preface
Figure i: TLA5000B series logic analyzer
The following table lists related documentation available for your logic analyzer. The documentation i
s available on the TLA Documentation CD and on the
Tektronix Web site (www.tektronix.com/manuals).
Related Documentation
Item Purpose Location
TLA Quick Start User M anuals
Online Help
Installation Quick Reference Cards High-level installation information
Installation Manuals
XYZs of Logic Analyzers
Declassication and Securities instructions
Application notes
Product Specications & Performance Verication Procedures
High-level operational overview
In-depth operation and UI help
Detailed rst-time installation information
Logic analyzer basics
Data security concerns specicto sanitizing or removing memory devices from Tektronix products
Collection of logic analyzer application specic notes
TLA Product specications and performance verication procedures
TLA5000B Series Logic Analyzer Installation Manual v
Preface
Related Documentation (cont.)
Item Purpose Location
TPI.NET Documentation
Detailed information for controlling the logic analyzer using .NET
Field upgrade kits
Optional Service Manuals Self-service documentation for modules
Upgrade information for your logic analyzer
and mainframes
vi TLA5000B Series Logic Analyzer Installation Manual
Basic Installation
Check the Shipping List
Site Considerations
This chapter describes all of the steps needed to install your Tektronix logic analyzer and its related accessories.
Check that you have received all of the parts of your logic analyzer using the shipping list. Also check the following:
That you have the correct power cords for your geographical area.
That you have backup copies of the installed software. Store the backup software in a safe location where you can easily retrieve the software for maintenance.
That you ha ve all the standard and optional accessories that you ordered.
Fill out and return the customer registration card that is packaged with this manual.
Read this section before installing the logic analyzer. This section describes site considerations, power requirements, and ground connections for your logic analyzer.
Table 1: Environmental characteristics
Feature Description
Temperature
Humidity
Operating (no media in drive)
+5 °C to +50 °C, 15 °C/hr maximum gradient, noncondensing (derated 1 °C per 305 m (1000 ft) above 1524 m (5000 ft) altitude)
Nonoperating (no media in drive)
-20 °C to +60 °C, 15 °C/hr maximum gradient, noncondensing
Operating (no media in drive)
20% to 80% relative humidity, noncondensing. Maximum wet bulb temperature: +29 °C (derates relative humidity to approximately 22% at +50 °C).
Nonoperating (no media in drive)
8% to 80% relative humidity, noncondensing. Maximum wet bulb temperature: +29 °C (derates relative humidity to approximately 22% at +50 °C).
TLA5000B Series Logic Analyzer Installation Manual 1
Basic Installation
Table 1: Environmental characteristics (cont.)
Feature Description
Altitude
Operating
To 3000 m (9843 ft), (derated 1 °C per 305 m (1000 ft) above 1524 m (5000 ft) altitude.
Nonoperating
12,190 m (40,000 ft )
CAUTION.
Allow a 5.1 cm (2 in) clearance around the top, back, and sides of the instrument to ensure proper cooling. Inadequate clearances can cause the instrument to overheat and shut down.
Table 2: Power considerations
Feature Description
Source Voltage and Frequency 100 V
Maximum Power Consumption
Steady-State Input Current
240 Watts line power maximum
4A
RMS
maximum
RMS
to 240 V
±10%,47Hzto63Hz
RMS
You can use the logic analyzer on a bench or on a cart in the normal position (on
bottom feet).
the
2 TLA5000B Series Logic Analyzer Installation Manual