Tektronix products are covered by U .S. and foreign patents, issued and pending. Information in this
publication supersedes that in all previously published material. Specifications and price change privileges
reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
TekExpress is a registered trademark of Tektronix, Inc.
TekExpress Serial ATA/SAS Online help, 076-0096-07.
Contacting Tektronix
Tektroni
14150 SW Karl Braun Drive
P. O . B o x 5 0 0
Beaverton, OR 97077
USA
x, Inc.
For p ro
duct information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to find contacts in your area.
Table of Contents
Introduction
Using Online Help........... ................................ ................................ .......................1
Related Documentation ............. ................................ .................................. .............1
Error Codes for TekExpress ....................................................................................178
Index
ivTekExpress Serial ATA/SAS Automated Solutions
IntroductionUsing Online Help
Using Online Help
Select Help from the menu to open the help file . You can also find an electronic copy of the help file in the
Documents directory on the 063-4068-XX DVD.
Table of Content (TOC) tab – Organizes the Help into book-like sections. Select a book icon to open a
section; select any of the topics listed under the book.
Index t ab – Enables you to scroll a list of alphabetical keywords. Select the topic of interest to bring
up the appropriate help page.
Search tab – Allows a text-based search.
Follow these steps:
1. Type the word or phrase you want to find in the search box. If the word or phrase is not found, try the
Index tab.
2. Choose a topic in the lower box, and then select the Display button.
General Help Functions:
Select the Print button from the Help topics menu bar to print a topic.
To return to the previous window, select the Back button.
Use hyperlinks to jump from one topic to another.
e Back button is grayed out or a jump is not available, choose the Help Topics button to return to
The term “SATA” refers t o Serial Advanced Technology Attachment.
The term “SAS” refers to Serial Attached SCSI.
The term “D UT” is an abbreviation for Device Under Test.
The term “se
lect” is a generic term that applies to the two mechanical methods of choosing an option:
using a mouse or using the touch screen.
Table 1: Icon descriptions
IconMeaning
This icon identifies important information.
This icon identifies conditions or practices that could result in loss of data.
This icon identifies additional information that will help you use the
application more efficiently.
xxx
2TekExpress Serial ATA/SAS Automated Solutions
IntroductionTechnical Support
Technical Support
Tektronix values your feedback on our products. To help us serve you better, please send us your
suggestions, ideas, or comments on your application or oscilloscope.
When you contact Tektronix Technical Support, please include the following information (be as specificas
possible):
General Information
All instru
Hardware options, if any.
Probes used.
Your name, company, mailing address, phone number, FAX number.
Please indicate if you would like to be contacted by Tektronix about your suggestion or comments.
ment model numbers.
Application Specific Information
Software version number.
Description of the problem such that technical support can duplicate the problem.
If possible, save the setup files for all the instruments used and the application.
ssible, save the TekExpress setup files, log.xml and status messages text file.
If po
If possible, save the waveform on which you are performing the measurement as a .wfm file.
Forward the information to technical support using one of these methods:
E-mail – techsupport@tektronix.com
FAX – (503) 627-5695
TekExpress Serial ATA/SAS Automated Solutions3
IntroductionTechnical Support
4TekExpress Serial ATA/SAS Automated Solutions
Getting StartedWhat is New in this Release
What is New in this Release
This version of TekExpress includes the following feature enhancements:
S-Parameters for SATA/SAS (6G)
Compliance needs for receiver UTD1.4
Receiver Margin testing using High Performance Scan and Select Scan Parameter Preset
PHY-TSG-OO
Accessories
About the Test Fixture
The TF-SATA-NE-ZP and TF-SATA-FE-ZP test fixtures that facilitate SATA/SAS Compliance testing are
manufactured a nd distributed by Crescent Heart Software, Inc. For more information, visit the Crescent
Heart Software Web site www.c-h-s.com
The TF-SATA-TPA-P, TF-SATA-TPA-R, TF-SATA-TPA-PRC and TF-SAS-TPA-P, TF-SAS-TPA-R,
TF-SAS-TPA-PRC test fixtures that facilitate SATA/SAS Compliance testing are manufactured
by Wilder Technologies. For more information, visit the Wilder Technologies Web site
http://www.wilder-tech.com/pdf.htm
The p in assignments for Wilder and CHS test fixturesareasfollows:
Table 2: Pin assignments
Wilder test fixtureCHS test fixture
Drive RP+HR+
Drive RP–HR–
Drive TP+HT+
Drive TP–HT–
xxx
About Frame Error Analyzer
B Enhancements for SAS/SATA
.
.
The Crescent Heart Software SATA II and III probe adapter facilitates Receiver Signalling Group test.
Visit www.c-h-s.com
for more information.
About Keithley Switch
The S46 Microwave Switch System is designed to simplify the automated switching needed
to test a wide range of telecommunications products and devices. For more information, visit
The power splitter part number 1580 Divider PWR DC-26.5 GHz is required in certain test configurations
of TekExpress SATA (RSG-RMT, Rx-Tx without RF switch) and SAS. For more information, visit the
Aeroflex/Weinschel Inc Web site www.aeroflex-weinschel.com
.
About the Test Adapter
The SAS Plug
hosts, and devices against the SAS specification 2.1.
Click the f
SAS Plug Test Adapter
SAS Receptacle Test Adapter (see page 7)
For more information on SAS test fixtures, refer to SAS Test Adapter User Manual provided by Wilder
Technologies.
and Receptacle Test Adapters (SAS-TPA-P and SAS-TPA-R) test SAS interface cables,
ollowing links to view sample fixture photos:
(see page 6)
6TekExpress Serial ATA/SAS Automated Solutions
Getting StartedAccessories
TekExpress Serial ATA/SAS Automated Solutions7
Getting StartedMinimum System Requirements
Minimum System Requirements
The minimum system requirements for a PC to run TekExpress are as follows:
Table 3: System requirements
Processor
Pentium 4/M or equivalent processor.
Operating SystemWindows XP Service Pack 2.
Memory
Hard Disk
512 MB of memory.
Approximately 2 GB of available hard-disk space for the recommended
installation, which includes full TekExpress installation and distributed
components.
DriveDVD drive
Display
Super VGA resolution or higher video adapter (800x600 minimum video
resolution for small fonts or 1024x768 minimum video resolution for large fonts).
The application is best viewed at 96 dpi display settings
1
.
SoftwareIConnect® and MeasureXtractor™ Signal Integrity TDR and S-parameter
Software (80SICON) Ver 4.0 or above.
Microsoft Excel 2002 or above.
Microsoft Internet Explorer 7.0 SP1 or later.
Microsoft Photo Editor 3.0 or equivalent software for image files viewing.
Adobe Reader 6.0 or equivalent software for viewing portable document
format (PDF) files.
Other DevicesMicrosoft compatible mouse or compatible pointing device.
Four USB ports (2 USB ports minimum).
PCI-GPIB or equivalent interface for instrument connectivity2.
xxx
1
If TekExpress is running on an instrument having a video resolution lower than 800x600 (for example, sampling oscilloscope), it is recommended
onnect a secondary monitor and this has to be enabled before launching the application.
to c
2
If TekExpress is installed on a Tektronix oscilloscope, the virtual GPIB port cannot be used by TekExpress for communicating with oscilloscope
applications.
If external devices like USB-GPIB or equivalent are used for instrument connectivity, ensure that the Talker Listener utility is enabled in the
DPO/DSA oscilloscope's GPIB menu.
8TekExpress Serial ATA/SAS Automated Solutions
Getting StartedApplication Directories and Usage
Application Directories and Usage
The application directory and associated files are organized as follows:
TekExpress Serial ATA/SAS Automated Solutions9
Getting StartedFile Name Extensions
The following table lists the default directory names and their usage:
Table 4: Default directory names and their usage
Directory namesUsage
InstallDir\TekExpressContains the TekExpress application and associated
files.
\TekExpress\TekExpress Serial ATAContains files specific to TekExpress Serial ATA.
\TekExpress Serial ATA\Compliance SuitesHas compliance specific sequence files. The folders
under this directory represent the devices to be
tested.
\TekExpress Serial ATA\Compliance Suites\SASIncludes the Drive folder.
\TekExpress Serial ATA\Compliance Suites\SAS\Drive\Includes the PHY-TSG-OOB and RX-TX folders.
These represent the suites of install tests for the
SAS drive devices.
\TekExpress Serial ATA\Compliance Suites\Serial ATA\The folders under this are Cable, Drive and Host.
\TekExpress Serial ATA\Compliance Suites\Serial ATA\CableIncludes the SI folder. This represents the suite of
install tests for SATA cables.
\TekExpress Serial ATA\Compliance Suites\Serial ATA\Drive\
\TekExpress Serial ATA \Compliance Suites\Serial ATA\Host\
\TekExpress Serial ATA\ACP
\TekExpress Serial ATA\SCP
\TekExpress Serial ATA\ICP
\TekExpress Serial ATA\Data Manager
\TekExpress Serial ATA\Data Storage
\TekExpress Serial ATA\Report Generator
\TekExpress Serial ATA\DocumentsIncludes the Method of Implementation documents
\TekExpress Serial ATA\Bin
\TekExpress Serial ATA\Lib
\TekExpress Serial ATA\Tools
xxx
Includes the PHY-TSG-OOB, RSG-RMT, and
RX-TX folders. These represent the suites of install
tests for the SATA d rive and host devices.
Includes instrument and application specific
interface libraries of TekExpress.
Includes the result management speci fic libraries of
TekExpress are present in these folders.
and technical documentation for the application.
Includes the Miscellaneous libraries of TekExpress.
File Name Extensions
The software uses the following file name extensions:
File name extensionDescription
.TekX
.seq
.xml
.PDF
xxx
10TekExpress Serial ATA/SAS Automated Solutions
The session fileissavedinthisformat.
The test sequence file.
The encrypted XML file that contains the test specificconfiguration
information. The log file extension is also xml.
The PDF file that details the method of implementation for the test.
Getting StartedHow to Activate the License
How to Activate the License
Follow the steps below to activate the license:
1. Click Help > About to view the license information.
2. Click the View Version Details link to check the version numbers of the installed test suites.
3. Click the View End-User License Agreement link to open the following Tektronix Software License
eement window. Click Print to print the License Agreement.
Agr
TekExpress Serial ATA/SAS Automated Solutions11
Getting StartedHow to Activate the License
4. Click License Info to view the available software options. This window shows the license key and the
various options with their status (active or inactive) with the current license key.
5. If you are activating the license for the first time, the license key field is empty. To activate the license,
connect the USB dongle to your computer, enter the license key provided in the license key certificate,
and clic
6. If you are reactivating the license, click Reactivate, enter the new license key and click Activate.
k Activate. If the activation is successful, a
sign is displayed next to the license key field.
12TekExpress Serial ATA/SAS Automated Solutions
Getting StartedBefore You Click Run
Before You Click Run
After you first launch TekExpress, it creates the following folders on your computer:
\My Documents\My TekExpress.
NOTE. Ensure that the “My TekExpress” folder has read and write access.
NOTE. If a user with a different Windows login ID launches TekExpress, a new
created under that user's
\My Documents\My TekExpress\Serial ATA. Similarly for SAS, the folder is \My
Documents\My TekExpress\SAS
\My Documents\My TekExpress\Serial ATA\Untitled Session. Every time the
TekExpress SATA.exe is launched a Untitled Session folder is created under Serial ATA
My Documents
folder.
.
My TekExpress
folder is
folder. The Untitled Session folder is deleted when you exit TekExpress.
CAUTIO
N. Each session has multiple files associated with it. Do not modify any of the session files and/or
folders as this may result in loss of data or corrupted session files.
The My
ID> My TekExpress
name><user ID> My TekExpress
TekExpress
folder is created as a shared folder with share name as <domain><user
(or if the PC is not connected to domain then share name is <Computer
).
The above shared folder is mapped as X: (X drive) on to the PC where TekExpress is running.
NOTE. If X drive is mapped to any other shared folder, TekExpress will display a Warning message
window asking to disconnect the X: drive manually.
Do the following before you click Run:
NOTE. Ensure that the network connectivity is enabled on the PC running the TekExpress.
1. Map (see page 14) the shared My TekExpress folder as X: (X drive) on all the instruments used
in test setup running Microsoft Windows Operating System. This share folder is used to save the
waveform files or any other file transfer operations.
2. Rightclickonthe
My TekExpress folderandopentheProperties dialog box. Select General tab
and then Advanced.IntheAdvanced Attributes window, ensure that the option Encrypt contents to
secure data is NOT selected. Click here
(see page 15) to view the picture.
TekExpress Serial ATA/SAS Automated Solutions13
Getting StartedBefore You C lick Run
3. Ensure that the SATA/SAS setup files provided with TekExpress DVD are available on the respective
instruments. For more details, refer to the
folder on the T
ekExpress DVD.
ReadmeFirst.txt located in the SATA Setup Files
4. Ensure that all the required instruments are properly warmed up, Signal Path Compensation (SPC)
page 15) is perf
ormed, followed by cable deskew.
Mapping My TekExpress folder
To map the My TekExpress folder on the instruments, follow the steps below:
1. Open Windo
2. From the Windows Explorer menu, select Tools > Map Network drive.
3. Select the Drive letter as X: (if there is any previous connection on X:, disconnect it first through
Tools > Disconnect Network drive menu of Windows Explorer).
4. In the Folder field, enter remote
John’s My TekExpress)
5. You can determine the IP address of the PC where “My TekExpress” folder exists by doing
the following:
Select Start > Run menu on the PC where My TekExpress folder exists.
Enter cmd and click Enter.
At command prompt, type ipconfig.
ws Explorer.
My TekExpress folder path (for example, \\192.158.97.65\
(see
14TekExpress Serial ATA/SAS Automated Solutions
Getting StartedBefore You Click Run
You ca n
1. On the oscilloscope main menu, click Utilities menu.
2. Click Instrument Calibration option.
find SPC by following the steps below:
TekExpress Serial ATA/SAS Automated Solutions15
Getting StartedBefore You C lick Run
16TekExpress Serial ATA/SAS Automated Solutions
Operating BasicsTekExpress Application Overview
TekExpress Application Overview
TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and
future test automation needs. It is a highly modular architecture that enables deploying automated test
solutions fo
automation solution for the Serial ATA Gen 1, Gen 2, and Gen 3 standards.
Options available with TekExpress Serial ATA and SAS are:
r various serial standards in a relatively short time. TekExpress provides a compliance test
PHY/TSG/OOB Test Suite— Includes PHY-TSG-OOB test s
tests.
PHY/TSG/OOB Test Suite — Includes PHY-TSG-OOB test suite SAS 2.0.
RSG-RMT Test Suite — Offers Phy Receiver Signal Requirements (RSG 1-2-3-5-6) and Receiver
Margin Test (RMT) for SATA Gen1, Gen2, and Gen3
Rx-Tx Test Suite — Includes Rx-Tx test suite for Serial ATA Gen1, Gen 2, and Gen 3 tests.
RMT Test Suite — Offers Receiver Margin Test (RMT) for SAS 2.0.
Rx-Tx Test Suite — Includes Rx-Tx test suite for SAS 2.0.
TekExpress SATA Bundle for the Host and Drive Test Suites.
SI Cable Tests for TekExpress SATA — Includes SI test suite for SATA electrical cable assembly
compliance test.
Key Features
The TekExpress provides the following salient features:
Complete SATA Gen1, Gen2, and Gen3 Test Coverage for Hosts, Drives and Cables.
PHY-TSG-OOB measurement for SAS 2.0.
uite Serial ATA Gen1, Gen2 and Gen3
Rx-Tx measurement for SAS 2.0.
Completely automated single button solution.
Significant Reduction In Testing Time Through Automation.
Performs all (UTD 1.2, UTD 1.3, and UTD 1.4 conformant) SATA MOI required Transmitter,
Receiver, and Channel measurements.
Single and Simple Microsoft Windows XP User Interface for Multi-instrument Testing.
Repeatable and accurate results.
Automatic HTML Report and SATA-IO (MS Excel) Scorecard Generation.
Receiver Margin Testing with High Performance Scan and Select Scan Parameter Preset methods.
Direct Synthesis and Device State Control Eliminates the Need for Multiple Sources.
TekExpress Serial ATA/SAS Automated Solutions17
Operating BasicsStarting the Application
PoweredbyNITestStand™.
Seamlessly Integrate with High-level TestStand Automation Layer.
Starting the Application
The application uses a USB dongle that contains the license key. This dongle must be present on the PC or
the instrument hosting the TekExpress application.
The application also c hecks for a file, called
is not found, instrument discovery is performed before launching TekExpress. The
contains information regarding instruments available on network.
When the application starts, it checks for the appropriate license key. If the valid license key is not present,
the application switches to the “Demo” mode. If the application fails to detect the dongle, it continues
toruninDemomode.
To start the application, you can do one of the following:
Click Start > Programs > Tektronix > TekExpress > TekExpress Serial ATA & SAS.Other
applications follow similar pattern.
Double-click the iconon the desktop.
If you have previously saved a session, double-click the session file stored under My
TekExpress\Serial ATA
When the application is launched it displays the splash screen providing launch information. The
application also checks for the presence and validity of the USB dongle.
or M y TekExpress\SAS.
Resources.xml, located in My TekExpress folder. If this file
Resources.xml file
NOTE. If the application was not terminated properly during the last use, a dialog box asks to recall the
previously unsaved session.
18TekExpress Serial ATA/SAS Automated Solutions
Operating BasicsResizing the Application Window
Resizing the Application Window
To minimize the application, clickon the application title bar. To restore the application to its
previous size, select
To maximize the application, click. To restore it to previous size, clickon the application
title bar.
Exiting the Application
To exit the application, do one of the following:
Click File > Exit.
Clickon the application title bar.
Global Controls
The menus and controls that appear outside the individual tabs are called “Global Controls”. These are
used to specify the devices to be tested.
in the Windows task bar.
Table 5: Controls a nd Functions
Control nameFunction
DUT
xxx
TekExpress Serial ATA/SAS Automated Solutions19
The device ID is specified at the global level and the
information is stored in the default location for all data
files. This field cannot be empty and does not allow these
special characters (.,..,...,\,/:?”<>|*). The maximum length
of characters allowed is 32.
This indicates whether your PC has enough memory to run
and test a measurement, which is typically < 10 Gb.
You will be able to run, pause, resume and stop the tests.
Operating BasicsFile Menu
File Menu
Click File on the application menu bar.
The File menu has the following selections:
MenuFunction
New SessionStarts a default session of TekExpress.
Open SessionOpens a saved session.
Save SessionSaves the session.
Save Session AsSaves a session in a different name.
Recently Recalled SetupLists all the recent and previously recalled setup files.
Save Report AsSaves the report in user specified location.
Print Preview Report
Print Report
Exit
xxx
View Menu
Click View on the application menu bar.
Previews the report before printing.
Opens the Windows “Print” dialog box.
Closes the application.
20TekExpress Serial ATA/SAS Automated Solutions
Operating BasicsTool s Menu
The View menu has the following selections:
MenuFunction
Log File
xxx
Opens the log (log.xml) file in the default viewer.
Tools Menu
Click Tools
on the application menu bar.
The Tools menu has the following selections:
MenuFunction
Instrument Bench (see page 21)Opens a dialog box showing the list of instruments attached to the test setup.
E-mail Settings (see page 23)Opens a dialog box showing e-mail setting details.
Debug – Deskew Panel (see page 24)Opens a control panel that allows to control the RF-switch for debugging and
cable deskew.
xxx
> Instrument Bench
Tools
The Instrument Bench window shows the list of VISA and Non-VISA resources found on different
rfaces/connections. It serves two purposes at the launch of TekExpress:
inte
Discovers the connected instruments.
Confirms the instrument connection setup.
TekExpress Serial ATA/SAS Automated Solutions21
Operating BasicsTools Menu
When you click Tools > Instrument Bench, the following dialog box is displayed:
Search Criteria: The various connections on which you can search. Non-VISA Resources are the
instruments that cannot be searched using TekVISA.
Retrieved Instruments: Displays the count and details of instruments that were discovered.
Last Updated: Displays the time when the last time search was performed.
TekVISA Refresh Timeout (Seconds): This time o ut specifies the maximum time that TekExpress
can wait for TekVISA update.
NOTE. TekExpress uses TekVISA for instrument search. Ensure that TekVISA is running on your system
before you refresh the instrument bench window.
Table 6: Retrieved Resources properties in the Instrument Bench window
TitleDescription
ConnectionShows the type of connection with the instrument.
Resource
Serial NumberShows the serial number of the resource.
OptionsShows the options available on the instrument.
Resource Address
xxx
1
The option column displays the options that fitinthefield. To view complete options on the instrument, move the mouse cursor over the option.
Shows the name of the resource.
1
Shows IP Address/Port number of the resource.
22TekExpress Serial ATA/SAS Automated Solutions
Operating BasicsTool s Menu
Table 7: Button controls on Instrument Bench dialog box
ButtonFunction
RefreshThe application searches on the selected connection for resources. While
searching res
Discovery window shows the connection currently being scanned and the
percentage of task completed.
ources it shows the Instrument Bench discovery window. The
CloseCloses the
xxx
dialog box.
Tools > E-mail Settings
Use the E-mail Settings utility to configure and set the e-mail options. The following fields are mandatory
for receiving e-mail notification from TekExpress:
1. Recipient Email Addresses. For example, User@domain.com.
2. Sender's Address.
3. SMTP Server address of the Mail server configured at client location.
If any of these fields are left blank, the settings are not saved and e-mail notification will not be sent.
Select the option “E-mail Test Results When Complete or on Error” has to be checked to receive the
e-mail. The attachment list depends on what you have selected while configuring the e-mail setup.
NOTE. Among the e-mail attachments, the Analysis Screenshot is not yet functional.
TekExpress Serial ATA/SAS Automated Solutions23
Operating BasicsTools Menu
Tools > Debug-Deskew Utility
The debug-deskew utility allows you to control the RF-switch state for setup debug purpose with primary
objective to perform a real-time oscilloscope deskew
the DUT TX terminals to the oscilloscope channels through the RF-switch. Using this utility, you can
set the oscil
various testing suites.
loscope deskew values that are retained by TekExpress SATA automation script throughout
(see page 24) operation for complex wiring path from
To ensure ac
channels, it is important to first deskew the oscilloscope channels before you take measurements of
your DUT.
curate results for two-channel measurements and differential signals acquired on two
The Debug Deskew Utility has the following functions:
State: Sets the Open/Close state of the RF switch channels.
er the setup requirement, select the channels on the panel to be closed or opened. The previous
As p
state of the RF switch is overridden by the new state. The current state of the RF Switch is not recalled
when the Debug panel is launched. Click
applied on the selected RF Switch. The selection shown by LEDs on the RF Switch should be same
the selection shown on the panel.
as
Read Deskew/Attenuation Values: Reads the current Deskew values of the real time oscilloscope.
With the selected switch state, you are expected to manually perform the deskew (by removing SMA
cable connection from TX terminals of CHS fixture at DUT and reconnecting them to Fast-edge output
of the oscilloscope). Once the deskew values are set on the oscilloscope, click
and the current state as seen on the panel is
.The
24TekExpress Serial ATA/SAS Automated Solutions
Operating BasicsHelp Menu
deskew values of all the four channels on the selected real time oscilloscope is read by TekExpress and
are retained during test automation sequencing.
Set Deskew/Attenuation values: Clickto restore the last values of
deskew/attenuation. It is restored to the selected oscilloscope.
NOTE. The address of the instruments are passed to the panel on the current suite selection (as detected
in instrument discovery). For example, in RX-TX and SI test suites, the Real Time Oscilloscope is not
available and so it will not be passed. Only the address of the RF Switch is passed, if detected.
For more information on how to deskew real time oscilloscopes, refer to the section Deskew operation
(see page 99).
Help Menu
Click Help on the application menu bar.
The Help menu has the following selections:
SelectionDescription or Function
TekExpress Help
About TekExpress (see page 11 )Displays application details such as software name, version
Activate License
x
xx
Displays TekExpress He lp (F1).
number and copyright.
Displays available software options and also about license
activation.
TekExpress Serial ATA/SAS Automated Solutions25
Operating BasicsHelp Menu
26TekExpress Serial ATA/SAS Automated Solutions
How ToSelect the Test(s)
Select the Test(s)
The application tests the following three types of SATA devices and SAS Drive devices for compliance.
Drive
Host
Cable
The Select p
This panel provides the following functions:
anel allows you to select tests to configure and run.
Select Standard
Select the appropriate standard Serial ATA or SAS.
Select Device
Select the Device type. And the test suite options is automatically updated corresponding to the device
selected.
TekExpress Serial ATA/SAS Automated Solutions27
How ToSelect the Test(s)
Select Test Suite
The application allows you to select a subset of tests to execute. Based on the test suite selected, the
Version drop-down list is populated.
Version
Select the appropriate version. For example, SATA Gen 1–UTD 1.2, SATA Gen 2–UTD 1.3, SATA
Gen 2–UTD 1.
NOTE. The SI test suite for cable measurement does not have any versions.
4orSAS2.0.
The table
has the following two columns:
Select: You can include or exclude any test for analysis.
Tes t Na me : Displays the name of the test.
NOTE. If any of the check box in the Select column is grayed, you cannot make any changes. It implies that
t is mandatory.
the tes
Once you select a row, the following options are available:
Table 8: Select panel buttons
ButtonDescription
Opens the configuration panel for the selected test.
Opens the PDF of method of implementation (MOI) for the selected test.
Opens the schematic for the selected test. This is useful if you want to
verify the test setup before running the test.
Selects all tests in the table.
28TekExpress Serial ATA/SAS Automated Solutions
How ToConfigure and Run the Test(s)
Table 8: Select p anel buttons (cont.)
ButtonDescription
Selects all the SATA-IO required tests in the grid and deselects all
informative tests in the table.
Deselects all tests in the table.
xxx
Configure and Run the Test(s)
Use the Configuration panel to create, view, and edit the parameters associated with the acquisition and the
analysis of the selected test.
You have the following options:
To choose between running the tests in a Compliance or User Defined mode.
To reload compliance mode values.
To change the parameters associated with the configuration of acquisition.
To change the parameters associated with analysis configuration.
hange the test limits in User Defined mode.
To c
The upper half of the Configure panel has general parameters that are common for all the tests under the
selected test suite that are editable. The lower half of the Configure panel has test specific parameters.
TekExpress Serial ATA/SAS Automated Solutions29
How ToConfigure and Run the Test(s)
NOTE. If any of the test parameters are grayed, it means that these parameters cannot be modified in
compliance mode. When you switch to user-defined mode, these parameters are editable.
Table 9: Test parameters
Parameters t
Acquire Parameters
Analyze parameters
oconfigure
Description
Shows the va
related to acquisition of a selected
test. These parameters can vary
from one tes
Number of Samples and Record
Length.
Shows the various parameters
related to analysis of a selected
test. The Analyze parameters
shows example of Jitter values,
whereas the link points out
JIT3 setup files.
rious parameters
t to another such as,
Limi
ts
Applies to a specific test. It shows
the measurement limits using
erent types of comparisons.
diff
30TekExpress Serial ATA/SAS Automated Solutions
How ToView and Select Connected Instruments
Table 9: Test parameters (cont.)
Parameters to configureDescription
CommentsSpecifies a comment up to 256
characters long for the selected
test.
Complia
xxx
Click
nce settings
Run in the Select pane l to run the selected tests.
For the SAS standard, the Configuration panel works the same way.
View and Select Connected Instruments
ewing Connected Instruments
Vi
The Tools > Instrument Bench menu item is used to discover connected instruments required for the
sts. The application uses TekVISA to discover t he connected instruments. Once the operation is done,
te
the Instrument Bench dialog box res umes operation and lists the instrument-related details based on t he
selected search criteria.
Restores the compliance settings.
Saves all changes that you made.
Dismisses the dialog box and does
not apply changes.
NOTE. When the TekVISA Instrument Manager checks for connected Instruments, the Instrument Bench
dialog box does not respond.
TekExpress Serial ATA/SAS Automated Solutions31
How ToView and Select Connected Instruments
For example, if you select LAN as the search criteria intheInstrumentBenchdialogandclickRefresh,
the TekVISA Instrument Manager checks for the instruments availability over LAN and the details of
the instrumen
t are displayed under Retrieved Instruments table.
You c an p
Instrument Manager does not find the instruments, the TekExpress application resumes the operation.
If you c
over the VISA layer can be searched.
rovide the time in the TekVISA Refresh Timeout (Seconds) field, within which if the TekVISA
hoose Non-VISA resources, all the instruments supported by TekExpress but not communicating
Selecting Connected Instruments
You can view the instruments connected in the Configuration panel. The upper half of the panel displays
the general parameters for the tests under the selected test suite.
Choose the instruments from the drop-down list as shown in the following figure:
32TekExpress Serial ATA/SAS Automated Solutions
How ToUse Prerecorded Waveforms for Analysis
Select th
NOTE. The list of instruments displayed is specific to the selected test suite. It does not show all the
connected instruments.
e “Do Not Use” option in the drop-down list for those instruments which are optional.
Use Prerecorded Waveforms for Analysis
From the Acquire tab, you can see unique acquisitions, acquisition parameters, acquisition status, and
prerecorded waveform files of the selected test suite. The Acquire panel is specific to a suite and gets
ted every time the selected test suite is changed. This panel shows the acquisition details for the tests
upda
in the currently selected suite. The tests with the common acquisition parameters are grouped together and
shown as a single acquisition.
NOTE. The acquire panel is disabled when the RSG-RMT test suite is selected. If you want to enable
or disable “Use Pre- Recorded Waveform files”, select a test suite other than RSG-RMT to enable the
acquire panel.
TekExpress Serial ATA/SAS Automated Solutions33
How ToUse Prerecorded Waveforms for Analysis
Column nameFunction
AcquisitionAcquisition Name
Test
StatusTest acquisition status of the running test passed at intervals.
Waveform File(s)Pre-recorded waveform files of unique acquisitions. You can select waveform
Name of the tests performing acquisitions. One or more test can perform the
same acquisitions.
files by selecting browse
waveform file using the standard file open window.
xxx
on individual cells. This allows you to select any
The following Acquire source options are available:
Use Pre-Recorded Waveform files: Enabling or disabling the option shows or hides the waveform
file column in the acquisition table.
When you save a session and then select this option, the DUT ID text box changes to a drop-down list,
in which you can select the DUT ID up to the point where the session was saved. A drop-down box
appears above the Waveform file column, showing the run details, including the date and time of each
run. If you select a run, corresponding data for that run is populated (such as the selected test, the test
configuration settings, and the test summary status).
Acquire Step by Step: Selecting this prompts you at the end of each acquisition before proceeding
to the next one.
Show Acquire Parameters: On enabling this option, the acquisition parameters for each unique
acquisition is displayed in the acquisition table.
When you select “Use Pre-Recorded Waveform Files”, the first column shows the waveform type and the
second column shows the tests that use that waveform type for analysis. The following guidelines help you
determine the correct prerecorded waveform for each test to be performed.
34TekExpress Serial ATA/SAS Automated Solutions
How ToUse Prerecorded Waveforms for Analysis
TIP. Select "Show Acquire Parameters" to verify the acquire parameters that are specifi ed and the
corresponding waveform.
Click the following links to get details on them:
Guidelines for PHY-TSG-OOB test suite waveforms
Each test requires a differential or single-endedwaveform. Forexample,asshowninthefollowingfigure,
the Unit Interval m easurement requires differential waveforms, and the Rise-fall time measurement
requires single-ended waveforms. Some combinations require both single-ended and differential
waveforms. You need to specify all required waveforms. The waveform file name must contain on the
following
(Diff), which are Single-Ended Positive (Pos), and which are Single-Ended Negative (Neg).
keywords: Diff, Pos, or Neg so that TekExpress can identify which waveforms are Differential
Guidel
Test suites such as Rx-Tx and SI need to have reference waveforms and waveforms with DUT. The
acqui
following folder location:
As mentioned in the guidelines for Rx-Tx test suite, the SI test suite also needs to have reference
waveforms and waveforms with DUT. The acquire panel allows you to specify only DUT waveforms.
The reference waveforms are stored in the following folder location:
View the progress of the analysis in the Analyze panel. As the analysis of each test is complete, the
result value is updated.
TekExpress Serial ATA/SAS Automated Solutions37
How ToView the Progress of Analysis
Analysi
The Analysis table contains the following:
The tests that are not yet started are shown with a “To be Started” status. A summarized status of the
currently running test is shown on the Status Messages panel.
The Status Messages window timestamps all runtime messages and displays them. You can do the
following:
NOTE. The Status Messages window is dockable and can be resized.
sTable
The test name.
The status of the tests that are being run.
Display Status: Enable/Disable status messages.
Auto Scroll: The status messages are scrolled automatically.
ear All: Clear all status messages in Status Window.
Cl
Save Status: Save all status messages in text file. Displays a standard save fi le window and saves the
atus messages in the user specified file.
st
38TekExpress Serial ATA/SAS Automated Solutions
How ToView the Report
View the Report
After the analysis, a report is automatically generated and displayed in the report panel. The report shows
the results of the tests, including device information and pass/fa il status of each test.
The report displays the Device identification, the date and time that was run, and execution time. Test
information like the Device Type, Version, Execution Time, Compliance Mode (Yes or No), and Overall
Test Result
the models, serial numbers, and firmware/software versions are shown. A table displays the Test Name,
Measurement Details, Low, High limit values, Test Result, Analysis Execution time and so on.
The Report View Area contains an HTML version of the report template. You can select any area of the
report and copy it to the clipboard to make it available to o ther application.
(Pass or Fail), MAC Address (in case of Receiver tests) are shown. Instrument information like
The View Scorecard option opens the report in Microsoft Excel
1
You must load Microsoft Excel 2002 before using the “View Scorecard” option.
1
.
TekExpress Serial ATA/SAS Automated Solutions39
How ToView Test Related Files
View Test Related Files
All the test related files for currently selected tests are always saved under My Documents\My
TekExpress\Serial ATA\Untitled Session
.
When you save a session, it is saved with the session name under the path
TekExpress\Serial ATA\SessionName
The session that is currently running is stored in the same path as “Untitled” until you save it.
WAR NING. Do not save a session named “Untitled” or “Backup” because there are application-specific
files and ar
A session folder can contain results for more than o ne DUT, and a DUT folder can contain more than one
run data f
Here is an example image of data storage:
e deleted when you exit the application.
older marked by date-time stamp as folder name.
for future references.
My Documents\My
40TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARMT Equipment Setup: Drive
RMT Equipment Setup: Drive
You need the following equipment to set up the application:
Required equipmentSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time OscilloscopeTektronix DPO/DSA72004/B, DPO/DSA71604/B, DP O/DSA71254/B, and
DPO/DSA70804/B
MSO71254, MSO71604, MSO70804 and MSO72004
Scope based Error Detector is supported only on DPO/DSA 70000B and
MSO70000
RF SwitchKeithley
Frame Error Analyzer
Test Fixture
Crescent
S46-6666A (Optional)
Heart Software SATA II and III probe adapter
Crescen
t Heart Software Test Fixture TF-SATA-NE-ZP
DUT
xxx
Wilder T
TF-SATA-TPA-PRC
ASATADrivetotest
est Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TekExpress Serial ATA/SAS Automated Solutions41
Application Examples for SATARMT Equipment Setup: Drive
Figure-1: Setup diagram for Drive RSG-RMT test suite with Scope based ED
NOTE. Click here
42TekExpress Serial ATA/SAS Automated Solutions
for details on pin a ssignments.
Application Examples for SATARMT-03-Gen3 (6.0GB/S) Receiver Margin Test
RMT-03-Gen3 (6.0GB/S) Receiver Margin Test
To run an RMT test on a Drive device, do the following:
1. Select Drive as the Device type, select RSG-RMT test suite and SATA Gen1 as the version.
2. Select RMT-03-Gen3 (6.0GB/S) Receiver Margin Test as the test to run and SATA Gen 1–UTD
1.4 as the version.
3. Click Show Schematic to view the setup diagram for the application.
4. Click Configure to configure the test parameters.
TekExpress Serial ATA/SAS Automated Solutions43
Application Examples for SATARMT-03-Gen3 (6.0GB/S) Receiver Margin Test
5. The defau
Frequency and End Frequency. Click Save to save the new settings.
NOTE. The Value for the Frame Error Counter should be selected as “Do not use”.
6. Enter the DUT ID in the DUT field of Select panel, and click Run.
7. The pro
lt settings are in User Defined Mode.Configure t he Analyze parameters, such as the Start
gress of the analysis is displayed in the Analyze tab.
44TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATAPHY-TSG-OOB Equipment Setup: Drive
8. View the test result report in the Report panel.
PHY-TSG-OOB Equipment Setup: Drive
You need the following equipment to set up the application:
Required equipmentSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time OscilloscopeTektronix DPO/DSA72004/B, DPO/DSA71604/B, DPO/DSA71254/B,
TDS6154C, and TDS6124C
Tektronix MSO71254, MSO71604, and MSO72004
For Gen1-only testing, the following oscilloscopes are also acceptable:
DPO/DSA70804/B, TDS6804B or MSO70804
RF SwitchKeithley S46-6666A (Optional)
Test F ixtu r e
DUT
xxx
Crescent Heart Software Test Fixture: TF-SATA-NE-ZP
Wilder Test Fixtures: TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
A SATA D rive to test
TekExpress Serial ATA/SAS Automated Solutions45
Application Examples for SATAPHY-TSG-OOB Equipment Setup: Drive
Setup diagram for Drive PHY-TSG-00B test suite without RF switch
Setup diagram for Drive PHY-TSG-OOB test suite (without RF switch)
46TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATAPHY-TSG-OOB Equipment Setup: Drive
Setup diagram for Drive PHY-TSG-00B test suite with RF switch
Setup diagram for Drive PHY-TSG-OOB test suite (with RF switch)
Connection guidelines.
For RF switch only: Do not connect the output of the signal source directly to the CHS fixture. The
signal must go through the RF switch.
For RF switch only: Terminate all unused RF switch outputs to 50 Ω.
The fixture notations in the diagram are with reference to revision 1.0 of the CHS fixture. If you are
using fixtures before revision 1.0, the fixture notations are in reverse order.
If you are using Wilder fixtures, click here for details on pin assignments.
If the DUT power cycle sequence is automated using DC output of the signal source, then do the
following:
For 20-pin Molex connector of AT/ATX power supply, connect Channel 1 of the DC output
to pin 14, ground to pin 15.
For 24-pin Molex connector of AT/ATX power supply, connect Channel 1 of the DC output
to pin 16, ground to pin 17.
TekExpress Serial ATA/SAS Automated Solutions47
Application Examples for SATAPHY01 - Unit Interval Test
PHY01 - Unit Interval Test
To verify that the Unit Interval of the SATA Drive transmitter is within the conformance limit, follow
these steps:
NOTE. The tes
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select the PHY-TSG-OOB as the Test Suite and SATA Gen 1–UTD 1.2 as the version.
3. Select PHY01 - Unit Interval.
4. Enter the DUT ID in the DUT field.
5. If you wa
t procedure is same for both drive and host except for a change in the connection diagram.
nt to verify the test setup before running the test(s), click Show Schematic.
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
48TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATAPHY01 - Unit Interval Test
NOTE. The parameters that are not grayed are editable. To change the instrument related values, select
from the drop-down list for each of the parameters.
7. You ca n c on figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program MOI document for information on how to configure the drive transmitter
click Show MOI in the Select panel.
tests,
8. Click Save to save the new settings for the selected test. If you want to restore the default settings,
Restore.
click
9. Click Run to run the selected tests.
10. The Acquire panel shows the status of the waveform acquisition.
TekExpress Serial ATA/SAS Automated Solutions49
Application Examples for SATAPHY01 - Unit Interval Test
11. The status of the tests is displayed in the Analyze panel.
12. After the tests complete, a report is generated and d isplayed in the Report panel.
50TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATATSG02 - Rise-Fall Time Test without RF Switch
You can save the report using the File > Save Report As option.
TSG02 - Rise-Fall Time Test without RF Switch
To verify that the Rise/Fall time of the SATA Drive transmitter is within the conformance limits, follow
these steps:
NOTE. Click here
NOTE. All cables must be d eskewed before performing this measurement.
1. Select Drive as the device type.
2. Sel
3. Enter the DUT ID in the DUT field.
4. Select TSG02 - Rise-Fall Time.
5. If you want to verify the test setup before running the test(s), click Show Schematic.
ect PHY-TSG-OOB as the Test Suite and SATA Gen 1–UTD 1.2 as the v ersion.
(see page 45) for information on the drive test equipment setup.
TekExpress Serial ATA/SAS Automated Solutions51
Application Examples for SATATSG02 - Rise-Fall Time Test without RF Switch
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
NOTE. Th
from the drop-down list for each of the param eters.
e parameters that are not grayed are editable. To change the instrument related values, select
7. You ca n c o n figure any test to help you analyze measurement results. To refer to the Serial ATA
nteroperability Program MOI document for information on how to configure the drive transmitter
I
tests, click Show MOI in the Select panel.
52TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATATSG02 - Rise-Fall Time Test without RF Switch
8. To run the test without using RF Switch, choose the Do not use option from the drop-down list for
the RF switch parameter in the Configure panel.
9. Click Save to save the new settings for the selected test and click Close.
10. Click Run to run the selected tests.
11. The Acquire panel shows the status of the waveform acquisition.
12. The status of the tests is displayed in the Analyze panel.
13. After the tests complete, a report is generated and displayed in the Report panel.
TekExpress Serial ATA/SAS Automated Solutions53
Application Examples for SATAOOB01 - OOB Signal Detection Threshold Test
OOB01 - OOB Signal Detection Threshold Test
To verify that the OOB Signal Detection Threshold of the SATA Drive receiver is within the conformance
limits, follow these steps:
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select PHY-TSG-OOB as the Test Suite and SATA Gen 1-UTD 1.2 as the version.
3. Enter the DUT ID in the DUT field.
4. Sel
5. If you want to verify the test setup before running the test(s), click Show Schematic.
ect the OOB01 - OOB Signal Detection Threshold option.
54TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATAOOB01 - OOB Signal Detection Threshold Test
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
7. If you want to change the parameters, choose User Defined Mode. The message reports that the
changes made to a test may no longer be compliant.
8. You ca n c on figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program MOI document for information on how to configure the drive receiver tests,
click Show MOI in the Select panel.
9. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restore.
TekExpress Serial ATA/SAS Automated Solutions55
Application Examples for SATAOOB01 - OOB Signal Detection Threshold Test
10. Click Run to run the selected tests.
11. The application automatically switches to the Acquire panel showing the waveform acquisition status.
12. The status of the tests is displayed in the Analyze panel.
13. After the tests complete, a report is generated and d isplayed in the Report panel.
56TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATAOOB01 - OOB Signal Detection Threshold Test
TekExpress Serial ATA/SAS Automated Solutions57
Application Examples for SATARSG-RMT Equipment Setup: Drive
RSG-RMT Equipment Setup: Drive
You need the following equipment to set up the application:
Required equipmentSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time OscilloscopeTektronix DPO/DSA72004/B, DPO/DSA71604/B, DPO/DSA71254/B,
TDS6154C, and TDS6124C
MSO71254, MSO71604, and MSO72004
Scope based Error Detector is supported only on DPO/DSA 70000B and
MSO70000
For Gen1-o
DPO/DSA70804/B, TDS6804B or MSO70804
RF SwitchKeithley S46-6666A (Optional)
Frame Er
Test Fi x
DUT
xxx
ror Analyzer
ture
Crescent Heart Software SATA II and III probe adapter
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
A SATA Drive to test
nly testing, the following oscilloscopes are also acceptable:
58TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARSG-RMT Equipment Setup: Drive
Figure-2: Setup diagram for Drive RSG-RMT test suite with CHS
TekExpress Serial ATA/SAS Automated Solutions59
Application Examples for SATARSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group
NOTE. Click here for details on pin assignments.
RSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group
To run an RSG test on a SATA Drive to conformance standards defined by SATA-IO Interoperability,
follow these steps:
NOTE. This test is applicable for both Drive and Host devices. The test procedure is the same for both drive
and host ex
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select RSG-RMT as the Test Suite and SATA Gen 1 as the version.
cept for a change in the connection diagram. Refer to Figure 5
for Host connection diagram.
3. Enter the DUT ID in the DUT field.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Selec
ttheRSG01-Gen1 (1.5Gb/s) Receiver Signalling Group option.
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
60TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group
7. If you want to change the parameters, choose User Defined Mode. The message reports that the
changes made to a test may no longer be compliant.
8. You ca n c on figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program, MOI document for information on how to configure the drive receiver tests,
click Show MO
9. Click Save to save the new settings for the selected test.
10. Click Run to run the selected tests.
The status of the tests is displayed in the Analyze panel.
I in the Select panel.
11. After the tests complete, a report is generated a nd displayed in the Report panel.
TekExpress Serial ATA/SAS Automated Solutions61
Application Examples for SATARMT- Receiver Margin Test
You can sa
ve the report using File > Save Report As option.
RMT- Receiver Margin Test
To run an RMT test on a Drive device, do the following:
1. Select Drive as the Device type, select RSG-RMT test suite and SATA Gen1 as the version.
2. Select RMT-01-Gen1 (1.5Gb/S) Receiver Margin Test as the test to run.
3. Click Show Schematic to view the setup diagram for the application.
NOTE. Refer to the Equipment Setup: Drive section for the setup diagram.
4. For information on how to configure the RMT test parameters, refer to RSG - RMT Method of
Implementation document by clicking Show MOI.
62TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARMT- Receiver Margin Test
5. Click Configure to configure the test parameters.
6. The default settings are in User Defined Mode.Configure the Analyze parameters, such as the StartFrequency and End Frequency. Click Save to save the new settings.
7. En
ter the DUT ID in the DUT field of Select panel, and click Run.
8. The progress of the Analysis is displayed in the Analyze tab.
TekExpress Serial ATA/SAS Automated Solutions63
Application Examples for SATARMT- Receiver Margin Test
9. The test result report is displayed in the Report panel.
64TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARSG-RMT Equipment Setup: Host
RSG-RMT Equipment Setup: Host
You need the following equipment to set up the application:
Required equipmentSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time OscilloscopeTektronix DPO/DSA72004/B, DPO/DSA71604/B, DPO/DSA71254/B, TDS6154C,
and TDS6124
C
Tektronix M
Scope base
MSO70000
For Gen1-only testing, the following oscilloscopes are also acceptable:
DPO/DSA70804/B, TDS6804B or MSO70804
RF SwitchKeithley S46-6666A (Optional)
Frame Error Analyzer
Test Fixture
DUT
xxx
Crescent Heart Software SATA II and III probe adapter
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and TF-SATA-TPA-PRC
A SATA Host to test
SO71254, MSO71604, and MSO72004
d Error Detector is supported only on DPO/DSA70000B and
TekExpress Serial ATA/SAS Automated Solutions65
Application Examples for SATARSG-RMT Equipment Setup: Host
Figure-3: Setup diagram for Host RSG-RMT test suite with CHS
66TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group
NOTE. Click here for details on pin assignments.
RSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group
To run a RSG test on a SATA Host to conformance standards defined by SATA-IO Interoperability,
follow these steps:
NOTE. The test procedure is the same for both drive and host except for a change in the connection
diagram. R
NOTE. All cables must be d eskewed before performing this measurement.
1. Select Host as the device type.
2. Select RSG-RMT test suite and SATA Gen 2-UTD 1.2 as the version.
efer to Figure 4
for the Drive connection diagram.
3. Enter the DUT ID in the DUT field.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Select the RSG-02 Gen2 (3.0Gb/s) Receiver Signalling Group.
6. Click Configure ifyouwanttoconfigure the test parameters. Observe that the default settings are
in Compliance mode.
7. If you want to change the parameters, choose User Defined Mode.
TekExpress Serial ATA/SAS Automated Solutions67
Application Examples for SATARSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group
8. You ca n c o n figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program MOI for information on how to configure the host receiver tests, click
Show MOI in the
9. Click Save to save the new settings for the selected test. If you want to restore the default settings,
click Restor
Select panel.
e.
10. Click Run to run the selected tests. The status of the tests is displayed in the Analyze panel.
11. After the tests run successfully, a report is generated and displayed in the Report panel.
68TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARx-Tx Equipment Setup: Drive
You can save the report using File > Save Report As menu option.
Rx-Tx Equipment Setup: Drive
ResourceSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Sampling OscilloscopeTektronix CSA/TDS/DSA 8200 with two 80E04/80E10 modules
RF SwitchKeithley S46-6666A (Optional)
Fixture
Test
SMA CablesFive pair of matched SMA Cables – 179-4944-00 or equivalent
AttenuatorsFour 6 dB attenuators
T
DU
xxx
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
One SMA cable to connect to trigger input
One SMA barrel adapter
ASATADrivetotest
TekExpress Serial ATA/SAS Automated Solutions69
Application Examples for SATARx01 - Pair Differential Impedance test
Figure-4: Setup diagram for Drive RXTX test suite
NOTE. Click here
for details on pin a ssignments.
Rx01 - Pair Differential Impedance test
To verify that the Pair Differential Impedance of the SATA Drive receiver is within the conformance
limits, follow these steps:
70TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARx01 - Pair Differential Impedance test
NOTE. This test is applicable for both Drive and Host devices. The test procedure is the same for both
drive and host except for a change in the connection diagram. Click here
the drive test
1. Select Drive as the device type.
2. Select RX-TX as the Test Suite and SATA Gen 1-UTD 1.2 as the version.
3. Enter the DUT ID in the DUT field.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
equipment setup.
(see page 45) for information on
5. Select Rx-
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
01 – Pair Differential Impedance.
NOTE. The parameters that are not grayed are editable. To change the instrument related values, select
from the drop-down list for each of the parameters.
7. You ca n c on figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program document for information on how to configure the drive receiver tests,
lick Show MOI in the Select panel.
c
8. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restore.
TekExpress Serial ATA/SAS Automated Solutions71
Application Examples for SATARx01 - Pair Differential Impedance test
9. Click Run to run the selected tests.
10. The Acquire panel shows the waveform acquisition status.
11.Th
e status of the tests is displayed in the Analyze panel.
72TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARx-Tx Equipment Setup: Host
12. After the tests complete, a report is generated and displayed in the Report panel.
Rx-Tx Equipment Setup: Host
ResourceSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8) or Tektronix AWG7102 (Option 1, 6)
Sampling OscilloscopeTektronix CSA/DSA/TDS 8200 with two 80E04/80E10 modules
RF SwitchKeithley S46-6666A (Optional)
TekExpress Serial ATA/SAS Automated Solutions73
Application Examples for SATARx-Tx Equipment Setup: Host
ResourceSupported mode
Test Fi x t ur e
Crescent Hear
Wilder Test Fi
l
t Software Test Fixture TF-SATA-NE-ZP
xtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
SMA CablesFive pair of matched SMA Cables – 179-4944-00 or equivalent
One SMA cable to connect to trigger input
One SMA barrel adapter
Attenuator
DUT
xxx
s
Two6dBatte
ASATAHost
nuators
to test
Figure-5: Setup diagram for Host RXTX test suite
74TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARx03 - Differential Mode Return Loss
NOTE. Click here for details on pin assignments.
Rx03 - Differential Mode R eturn Loss
To verify that the Differential Mode Return Loss of the SATA Host receiver is within the conformance
limits, follow these steps:
NOTE. This test is applicable for both Drive and Host devices. The test procedure is identical for both drive
and host ex
1. Select Host as the device type.
2. Select RX-TX as the Test Suite and SATA Gen 2-UTD 1.2 as the version.
3. Enter the DUT ID in the DUT field.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
cept for a change in the connection diagram. Refer to Figure 6
for Drive connection diagrams.
5. Select Rx06 - Differential Mode Return Loss.
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
7. If you want to change the parameters, choose User Defined Mode. The message reports that the
changes made to a test may no longer be compliant.
TekExpress Serial ATA/SAS Automated Solutions75
Application Examples for SATARx03 - Differential Mode Return Loss
8. You ca n c o n figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program MOI document for information on how to configure the host receiver tests,
click Show MOI
9. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restor
in the Select panel.
e.
10. Click Run to run the selected tests.
11. The application automatically switches to the Acquire panel. The status of the waveform acquisition is
displayed in this panel.
76TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATARx03 - Differential Mode Return Loss
12. The status of the tests is displayed in the Analyze panel.
13. After the tests complete, a report is generated and displayed in the Report panel.
You can save the report using File > Save Report As option.
TekExpress Serial ATA/SAS Automated Solutions77
Application Examples for SATASI Equipment Setup
SI Equipment Setup
ResourceSupported model
Sampling OscilloscopeTektronix CSA/DSA/TDS 8200 with four 80E04/80E10 modules
Test Fi x t ur e
SMA CablesFour pairs of matched SMA Cables 179-4944-01 or equivalent
DUT
xxx
Connect t
he equipment as shown in the following diagram:
Two Crescent Heart Software Fixture TF-SATA-FE-ZP
Two SMA barrel adapters
A SATA Cable to test
gure-6: Setup diagram for Cable SI test suite
Fi
NOTE. Click here for details on pin assignments.
78TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATASI-02 - Cable Absolute Differential Impedance test on a SATA Cable
SI-02 - Cable Absolute Differential Impedance test on a SATA Cable
To run an SI test on a SATA Cable to conformance standards defined b y SATA-IO Interoperability, follow
these steps:
NOTE. This te
1. Select Cable as the device type.
2. Select SI as the Test Suite.
NOTE. There is no test suite version for an SI test.
3. Enter the DUT ID in the DUT field.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Select the SI-02 – Cable Absolute Differential Impedance.
st is applicable only for SATA cables.
ick Configure to configure the test parameters. Observe that the default settings are in Compliance
6. Cl
mode.
f you want to change the parameters, choose User Defined Mode. The message reports that the
7.I
changes made to a test may no longer be compliant.
TekExpress Serial ATA/SAS Automated Solutions79
Application Examples for SATASI-02 - Cable Absolute Differential Impedance test on a SATA Cable
8. You ca n c o n figure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program MOI document for information on how to configure the cable tests, click
Show MOI in the Select panel.
9. Click Save to save the new settings for the test selected. If you want to restore the default settings,click Restore.
10. Click Run to run the selected tests.
11. The application aut
acquisition.
omatically switches to the Acquire panel. This shows the status of the waveform
80TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATASI-02 - Cable Absolute Differential Impedance test on a SATA Cable
12. On completion of the acquisition, the application switches to the Analyze panel. This panel shows the
status of the analysis.
13. After the tests run successfully, a report is generated and displayed in the Report panel.
You can save the report using the File > Save Report As option.
TekExpress Serial ATA/SAS Automated Solutions81
Application Examples for SATASI-02 - Cable Absolute Differential Impedance test on a SATA Cable
82TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SASPHY-TSG-OOB Drive Test Equipment Setup
PHY-TSG-OOB D
Click here (s
ee page
rive Test Equipment Setup
45) for information on the drive test equipment setup.
TekExpress Serial ATA/SAS Automated Solutions83
Application Examples for SASTest 5.2.1-Tx SSC Modulation Type Test
Test 5.2.1-Tx SSC Modulation Type Test
Click here (see page 45) for information on the drive test equipment setup.
To verify that the 5.2.1-TX SSC Modulation Type of the SAS Drive transmitter is within the conformance
limit, follow these steps:
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select the PHY-TSG-OOB as the Test Suite and SAS 2.0 as the version.
3. Select Test 5.2.1-Tx SSC Modulation Type.
4. Enter the DUT ID in the DUT field.
5. If you wa
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mode.
nt to verify the test setup before running the test(s), click Show Schematic.
NOTE. The parameters that are not grayed are editable. To change the instrument related v alues, select
from the drop-down list for each of the param eters.
84TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SASTest 5.2.1-Tx SSC Modulation Type Test
7. You c a n c o n figure any test to help you analyze measurement results. To refer to the SAS
Interoperability Program MOI document for information on how to configure the drive transmitter
tests, click S
8. Click Save to save the new settings for the selected test. If you want to restore the default settings,click Restore.
how MOI in the Select panel.
9. Click Run to run the selected tests.
10. The Acquire panel shows the status of the waveform acqu
11. The status of the tests is displayed in the Analyze panel.
isition.
TekExpress Serial ATA/SAS Automated Solutions85
Application Examples for SASTest 5.2.1-Tx SSC Modulation Type Test
12. After the tests complete, a report is generated and d isplayed in the Report panel.
can save the report using the File > Save Report As option.
You
86TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SASRx-Tx Equipment Setup: Drive
Rx-Tx Equipment Setup: Drive
ResourceSupported model
Signal SourceTektronix AWG7122B (Option 1, 6, 8)
Sampling OscilloscopeTektronix CSA/TDS/DSA 8200 with two 80E04/80E10 modules
RF SwitchKeithley S46-6666A (Optional)
Test F ixtu r e
SMA Cable
s
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-T
Five pair
PA- PRC
of matched SMA Cables – 179-4944-00 or equivalent
One SMA ca
One SMA ba
AttenuatorsFour 6 dB attenuators
DUT
xxx
A SAS Drive to test
ble to connect to trigger input
rrel adapter
TekExpress Serial ATA/SAS Automated Solutions87
Application Examples for SASRx-Tx Equipment Setup: Drive
Figure-7: Setup diagram for Drive RXTX test suite
NOTE. Click here
88TekExpress Serial ATA/SAS Automated Solutions
for details on pin a ssignments.
Application Examples for SASTest 5.4.2-RX Common-Mode Return Loss (SCC11)
Test 5.4.2-RX Common-Mode Return Loss (SCC11)
To verify that the Rx Common-Mode Return Loss of the SAS Drive transmitter is within the conformance
limit, follow these steps:
1. Select Drive as the device type.
2. Select RX-TX as the Test Suite and SAS 2 .0 as the version.
3. Enter the DUT ID in the DUT field.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Select Te s
6. Click Configure to configure the test parameters. Observe that the default settings are in Compliance
mod
t 5.4.2-RX Common-Mode Return Loss (SCC11).
e.
NOTE. The parameters that are not grayed are editable. To change the instrument related values, select
from the drop-down list for each of the parameters.
7. You c a n c o n figure any test to help you analyze measurement results. To refer to the SAS
Interoperability Program document for information on how to configure the drive receiver tests,
click Show MOI in the Select panel.
8. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restore.
TekExpress Serial ATA/SAS Automated Solutions89
Application Examples for SASTest 5.4.2-RX Common-Mode Return Loss (SCC11)
9. Click Run to run the selected tests.
10. The Acquire panel shows the waveform acquisition status.
11. The status of the tests is displayed in the Analyze panel.
90TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SASTest 5.4.2-RX Common-Mode Return Loss (SCC11)
12. After the tests complete, a report is generated and displayed in the Report panel.
TekExpress Serial ATA/SAS Automated Solutions91
Application Examples for SASTest 5.4.2-RX Common-Mode Return Loss (SCC11)
92TekExpress Serial ATA/SAS Automated Solutions