Tektronix TekExpress Serial ATA/SAS Help, TekExpress Serial ATA/SAS Online Help

xx
TekExpress® Serial ATA/SAS
ZZZ
Automated Solutions
Printable Online Help
*P077004407*
077-0044-07
TekExpress® Serial ATA/SAS Automated Solutions
ZZZ
www.tektronix.com
077-0044-07
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U .S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
TekExpress is a registered trademark of Tektronix, Inc.
TekExpress Serial ATA/SAS Online help, 076-0096-07.
Contacting Tektronix
Tektroni 14150 SW Karl Braun Drive P. O . B o x 5 0 0 Beaverton, OR 97077 USA
x, Inc.
For p ro
duct information, sales, service, and technical support: In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to nd contacts in your area.

Table of Contents

Introduction
Using Online Help........... ................................ ................................ ....................... 1
Related Documentation ............. ................................ .................................. ............. 1
Conventions .............................. .................................. ................................ ......... 2
Technical Support ......................... ................................ .................................. ....... 3
Getting Started
What is New in this Release............................................ ................................ ........... 5
Accessories..................... ................................ ................................ ..................... 5
Minimu
Application Directories and Usage ........ .................................. ................................ ..... 9
File Name Extensions ............................................................................................. 10
How to Activate the License ..................... .................................. .............................. 11
Before You Click Run............................................................................................. 13
m System Requirements................. .................................. ............................... 8
Table of Contents
Operating Basics
TekExpress Application Overview .............................................................................. 17
Key Features .................................................................................................. 17
Starting the Application..................... ................................ ................................ ...... 18
Resizing the Application Window................. ................................ .............................. 19
Exiting the Application ... .. . .. . .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. . .. . .. .. . . 19
Global Controls .......... .................................. ................................ ........................ 19
Menus
File Menu.......................... ................................ ................................ ............ 20
View Menu ........ .................................. ................................ .......................... 20
Tools Menu .................................................................................................... 21
Help Menu..................................................................................................... 25
How To
Select the Test(s)..................... ................................ .................................. ............ 27
Congure and Run the Test(s).............. ................................ .................................. .... 29
View and Select Connected Instruments ............................ ................................ ............ 31
Use Prerecorded Waveforms for Analysis.... .................................. ................................ 33
View the Progress of Analysis ................... ................................ ................................ 37
View the Report.................................................................................................... 39
View Test Related Files ......................... ................................ .................................. 40
TekExpress Serial ATA/SAS Automated Solutions i
Table of Contents
Application Examples for SATA
Receiver Example for Scope based Error Detector
RMT Equipment Setup: Drive .............................................................................. 41
RMT-03-Gen3 (6.0GB/S) Receiver Margin Test ......................................................... 43
PHY-TSG-OOB Suite
Testing a Drive
PHY-TSG-OOB Equipment Setup: Drive ...... ................................ ...................... 45
PHY01 - Unit Interval Test ............................................................................. 48
TSG02 - Rise-Fall Time Test without RF Switch .................................................... 51
OOB01 - OOB Signal Detection Threshold Test..................................................... 54
RSG-RMT Suite
Testing a Drive
RSG-RMT Equipment Setup: Drive....................... .................................. .......... 58
RSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group.. . .. .. . .. . .. . .. . .. ... .. . .. . .. . .. . .. ... .. . .. . .. 60
T- Receiver Margin Test.... ................................ .................................. ...... 62
RM
Testing a Host
RSG-RMT Equipment Setup: Host................................ ................................ .... 65
RSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group.. . .. .. . .. . .. . .. . .. ... .. . .. . .. . .. . .. ... .. . .. . .. 67
Rx-Tx Suite
Testing a Drive
Rx-Tx Equipment Setup: Drive ........................................................................ 69
Rx01 - Pair Differential Impedance test ............................................................... 70
Testing a Host
Rx-Tx Equipment Setup: Host ......................................................................... 73
Rx03 - Differential Mode Return Loss ................................................................ 75
SI Cable test
SI Equipment Setup .............. ................................ ................................ ............ 78
SI-02 - Cable Absolute Differential Impedance test on a SATA Cable ................................. 79
Application Examples for SAS
PHY-TSG-OOB Suite
Testing a Drive
PHY-TSG-OOB Drive Test Equipment Setup................................ ........................ 83
Test 5.2.1-Tx SSC Modulation Type Test ................. .................................. .......... 84
Rx-Tx Suite
Testing a Drive
Rx-Tx Equipment Setup: Drive ........................................................................ 87
Test 5.4.2-RX Common-Mode Return Loss (SCC11) ............... ................................ 89
Receiver Margin Test
RMT Methods ..................................................................................................... 93
Receiver Margin Testing.......................................................................................... 96
ii TekExpress Serial ATA/SAS Automated Solutions
Deskew Operation
Deskewing Real Time Oscilloscopes.. . .. . .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. ... .. . .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. . .. . 99
Manual Deskew Procedure for Sampling Oscilloscopes . .. . .. . .. . .. .. . .. . .. .. . .. . .. . .. . .. .. . .. . .. .. . .. . .. . . 100
Mixed Mode TDR Channel Alignment with Independent TDR Source.................. ............ 100
Sampling Oscilloscope Deskew during Rx-Tx Testing for Test Setup without RF Switch . . .. .. . .. . .. . 104
Overriding Acquire Parameters
About Overriding Acquire Parameters ........................................................................ 107
Acquire parameters with “Auto
Acquire Parameters with “Manually” Option ........... .................................. .............. 109
matically” option................... ................................ .... 107
Pattern Generation Utility
Using the Pattern Generation Utility to Test Receivers . .. . .. . .. ... .. . .. . .. . .. ... ... .. . .. . .. . .. ... .. . .. . .. . . 111
Calibration Procedure ........................................................................................... 113
User Conguration for TekExpress S ATA
Setting User Option for SATA DUT Power Cycle Method ... .. . .. . .. . .. . .. .. . .. . .. . .. ... .. . .. . .. . .. ... .. . . 117
Table of Contents
Calibration and Verication of Jitter Measurement Devices
About JTF Calibration and Verication ....................................................................... 119
Basic Procedure.................. .................................. ................................ .............. 120
Detailed Procedure ...................... ................................ ................................ ........ 120
AWG C alibration Procedure for OOB tests
OOB-01 Level Calibration Procedure using DPOJET Application........................................ 129
OOB-01 Calibration Procedure without using the DPOJET Application ......... ........................ 132
TekExpress Programmatic Interface
About the Programmatic Interface............................................................................. 137
Server and Client Proxy Objects ............................. ................................ .................. 138
Remote Proxy Object....................................................................................... 138
Client Proxy Object......................................................................................... 139
Client Programmatic Interface: An Example................................................................. 141
SATA Application Command Arguments and Queries...................................................... 144
Handle Error Codes ............................................................................................. 170
Program Example................................................................................................ 170
Troubleshooting
Instrument Connectivity .... ................................ ................................ .................... 173
User Interface ........................ ................................ .................................. .......... 173
TestStand Run time Engine Installation......... ................................ .............................. 174
Test Limit is Single Sided ............ ................................ .................................. ........ 174
TekExpress Serial ATA/SAS Automated Solutions iii
Table of Contents
Report shows as NAN..................................... .................................. .................... 175
Reference
Instrument Connectivity using GPIB Cable .................................................................. 177
Shortcut Keys .......... ................................ ................................ .......................... 177
Error Codes for TekExpress .................................................................................... 178
Index
iv TekExpress Serial ATA/SAS Automated Solutions

Introduction Using Online Help

Using Online Help

Select Help from the menu to open the help le . You can also nd an electronic copy of the help le in the Documents directory on the 063-4068-XX DVD.
Table of Content (TOC) tab – Organizes the Help into book-like sections. Select a book icon to open a section; select any of the topics listed under the book.
Index t ab – Enables you to scroll a list of alphabetical keywords. Select the topic of interest to bring up the appropriate help page.
Search tab – Allows a text-based search.
Follow these steps:
1. Type the word or phrase you want to nd in the search box. If the word or phrase is not found, try the Index tab.
2. Choose a topic in the lower box, and then select the Display button.
General Help Functions:
Select the Print button from the Help topics menu bar to print a topic.
To return to the previous window, select the Back button.
Use hyperlinks to jump from one topic to another.
e Back button is grayed out or a jump is not available, choose the Help Topics button to return to
If th the originating help folder.
ated Documentation
Rel
Technical Specication documents
http://www.tek.com/Measurement/applications/serial_data/sata.html
tp://ftp.iol.unh.edu/pub/sas/test_suite/SAS-2_6Gbps_Physical_Layer_Test_Suite_(v1.00).pdf
f
TekExpress Serial ATA/SAS Automated Solutions 1
Introduction Conventions

Conventions

Online Help uses the following conventions:
The term “SATA” refers t o Serial Advanced Technology Attachment.
The term “SAS” refers to Serial Attached SCSI.
The term “D UT” is an abbreviation for Device Under Test.
The term “se
lect” is a generic term that applies to the two mechanical methods of choosing an option:
using a mouse or using the touch screen.
Table 1: Icon descriptions
Icon Meaning
This icon identies important information.
This icon identies conditions or practices that could result in loss of data.
This icon identies additional information that will help you use the application more efciently.
xxx
2 TekExpress Serial ATA/SAS Automated Solutions
Introduction Technical Support

Technical Support

Tektronix values your feedback on our products. To help us serve you better, please send us your suggestions, ideas, or comments on your application or oscilloscope.
When you contact Tektronix Technical Support, please include the following information (be as specicas possible):
General Information
All instru
Hardware options, if any.
Probes used.
Your name, company, mailing address, phone number, FAX number.
Please indicate if you would like to be contacted by Tektronix about your suggestion or comments.
ment model numbers.
Application Specic Information
Software version number.
Description of the problem such that technical support can duplicate the problem.
If possible, save the setup les for all the instruments used and the application.
ssible, save the TekExpress setup les, log.xml and status messages text le.
If po
If possible, save the waveform on which you are performing the measurement as a .wfm le.
Forward the information to technical support using one of these methods:
E-mail – techsupport@tektronix.com
FAX – (503) 627-5695
TekExpress Serial ATA/SAS Automated Solutions 3
Introduction Technical Support
4 TekExpress Serial ATA/SAS Automated Solutions

Getting Started What is New in this Release

What is New in this Release

This version of TekExpress includes the following feature enhancements:
S-Parameters for SATA/SAS (6G)
Compliance needs for receiver UTD1.4
Receiver Margin testing using High Performance Scan and Select Scan Parameter Preset
PHY-TSG-OO

Accessories

About the Test Fixture
The TF-SATA-NE-ZP and TF-SATA-FE-ZP test xtures that facilitate SATA/SAS Compliance testing are manufactured a nd distributed by Crescent Heart Software, Inc. For more information, visit the Crescent Heart Software Web site www.c-h-s.com
The TF-SATA-TPA-P, TF-SATA-TPA-R, TF-SATA-TPA-PRC and TF-SAS-TPA-P, TF-SAS-TPA-R, TF-SAS-TPA-PRC test xtures that facilitate SATA/SAS Compliance testing are manufactured by Wilder Technologies. For more information, visit the Wilder Technologies Web site
http://www.wilder-tech.com/pdf.htm
The p in assignments for Wilder and CHS test xturesareasfollows:
Table 2: Pin assignments
Wilder test xture CHS test xture
Drive RP+ HR+
Drive RP– HR–
Drive TP+ HT+
Drive TP– HT–
xxx
About Frame Error Analyzer
B Enhancements for SAS/SATA
.
.
The Crescent Heart Software SATA II and III probe adapter facilitates Receiver Signalling Group test. Visit www.c-h-s.com
for more information.
About Keithley Switch
The S46 Microwave Switch System is designed to simplify the automated switching needed to test a wide range of telecommunications products and devices. For more information, visit
http://www.keithley.com/applications/aerospace/?mn=S46
TekExpress Serial ATA/SAS Automated Solutions 5
.
Getting Started Accessories
About the Power Splitter
The power splitter part number 1580 Divider PWR DC-26.5 GHz is required in certain test congurations of TekExpress SATA (RSG-RMT, Rx-Tx without RF switch) and SAS. For more information, visit the Aeroex/Weinschel Inc Web site www.aeroex-weinschel.com
.
About the Test Adapter
The SAS Plug hosts, and devices against the SAS specication 2.1.
Click the f
SAS Plug Test Adapter
SAS Receptacle Test Adapter (see page 7)
For more information on SAS test xtures, refer to SAS Test Adapter User Manual provided by Wilder Technologies.
and Receptacle Test Adapters (SAS-TPA-P and SAS-TPA-R) test SAS interface cables,
ollowing links to view sample xture photos:
(see page 6)
6 TekExpress Serial ATA/SAS Automated Solutions
Getting Started Accessories
TekExpress Serial ATA/SAS Automated Solutions 7
Getting Started Minimum System Requirements

Minimum System Requirements

The minimum system requirements for a PC to run TekExpress are as follows:
Table 3: System requirements
Processor
Pentium 4/M or equivalent processor.
Operating System Windows XP Service Pack 2.
Memory
Hard Disk
512 MB of memory.
Approximately 2 GB of available hard-disk space for the recommended installation, which includes full TekExpress installation and distributed components.
Drive DVD drive
Display
Super VGA resolution or higher video adapter (800x600 minimum video resolution for small fonts or 1024x768 minimum video resolution for large fonts). The application is best viewed at 96 dpi display settings
1
.
Software IConnect® and MeasureXtractor™ Signal Integrity TDR and S-parameter
Software (80SICON) Ver 4.0 or above.
Microsoft Excel 2002 or above.
Microsoft Internet Explorer 7.0 SP1 or later.
Microsoft Photo Editor 3.0 or equivalent software for image les viewing.
Adobe Reader 6.0 or equivalent software for viewing portable document
format (PDF) les.
Other Devices Microsoft compatible mouse or compatible pointing device.
Four USB ports (2 USB ports minimum).
PCI-GPIB or equivalent interface for instrument connectivity2.
xxx
1
If TekExpress is running on an instrument having a video resolution lower than 800x600 (for example, sampling oscilloscope), it is recommended
onnect a secondary monitor and this has to be enabled before launching the application.
to c
2
If TekExpress is installed on a Tektronix oscilloscope, the virtual GPIB port cannot be used by TekExpress for communicating with oscilloscope applications. If external devices like USB-GPIB or equivalent are used for instrument connectivity, ensure that the Talker Listener utility is enabled in the DPO/DSA oscilloscope's GPIB menu.
8 TekExpress Serial ATA/SAS Automated Solutions
Getting Started Application Directories and Usage

Application Directories and Usage

The application directory and associated les are organized as follows:
TekExpress Serial ATA/SAS Automated Solutions 9
Getting Started File Name Extensions
The following table lists the default directory names and their usage:
Table 4: Default directory names and their usage
Directory names Usage
InstallDir\TekExpress Contains the TekExpress application and associated
les.
\TekExpress\TekExpress Serial ATA Contains les specic to TekExpress Serial ATA.
\TekExpress Serial ATA\Compliance Suites Has compliance specic sequence les. The folders
under this directory represent the devices to be tested.
\TekExpress Serial ATA\Compliance Suites\SAS Includes the Drive folder.
\TekExpress Serial ATA\Compliance Suites\SAS\Drive\ Includes the PHY-TSG-OOB and RX-TX folders.
These represent the suites of install tests for the SAS drive devices.
\TekExpress Serial ATA\Compliance Suites\Serial ATA\ The folders under this are Cable, Drive and Host.
\TekExpress Serial ATA\Compliance Suites\Serial ATA\Cable Includes the SI folder. This represents the suite of
install tests for SATA cables.
\TekExpress Serial ATA\Compliance Suites\Serial ATA\Drive\
\TekExpress Serial ATA \Compliance Suites\Serial ATA\Host\
\TekExpress Serial ATA\ACP
\TekExpress Serial ATA\SCP
\TekExpress Serial ATA\ICP
\TekExpress Serial ATA\Data Manager
\TekExpress Serial ATA\Data Storage
\TekExpress Serial ATA\Report Generator
\TekExpress Serial ATA\Documents Includes the Method of Implementation documents
\TekExpress Serial ATA\Bin
\TekExpress Serial ATA\Lib
\TekExpress Serial ATA\Tools
xxx
Includes the PHY-TSG-OOB, RSG-RMT, and RX-TX folders. These represent the suites of install tests for the SATA d rive and host devices.
Includes instrument and application specific interface libraries of TekExpress.
Includes the result management speci c libraries of TekExpress are present in these folders.
and technical documentation for the application.
Includes the Miscellaneous libraries of TekExpress.

File Name Extensions

The software uses the following le name extensions:
File name extension Description
.TekX .seq
.xml
.PDF
xxx
10 TekExpress Serial ATA/SAS Automated Solutions
The session leissavedinthisformat.
The test sequence le.
The encrypted XML le that contains the test specicconfiguration information. The log le extension is also xml.
The PDF le that details the method of implementation for the test.
Getting Started How to Activate the License

How to Activate the License

Follow the steps below to activate the license:
1. Click Help > About to view the license information.
2. Click the View Version Details link to check the version numbers of the installed test suites.
3. Click the View End-User License Agreement link to open the following Tektronix Software License
eement window. Click Print to print the License Agreement.
Agr
TekExpress Serial ATA/SAS Automated Solutions 11
Getting Started How to Activate the License
4. Click License Info to view the available software options. This window shows the license key and the various options with their status (active or inactive) with the current license key.
5. If you are activating the license for the rst time, the license key eld is empty. To activate the license, connect the USB dongle to your computer, enter the license key provided in the license key certicate,
and clic
6. If you are reactivating the license, click Reactivate, enter the new license key and click Activate.
k Activate. If the activation is successful, a
sign is displayed next to the license key eld.
12 TekExpress Serial ATA/SAS Automated Solutions
Getting Started Before You Click Run

Before You Click Run

After you first launch TekExpress, it creates the following folders on your computer:
\My Documents\My TekExpress.
NOTE. Ensure that the “My TekExpress” folder has read and write access.
NOTE. If a user with a different Windows login ID launches TekExpress, a new
created under that user's
\My Documents\My TekExpress\Serial ATA. Similarly for SAS, the folder is \My Documents\My TekExpress\SAS
\My Documents\My TekExpress\Serial ATA\Untitled Session. Every time the TekExpress SATA.exe is launched a Untitled Session folder is created under Serial ATA
My Documents
folder.
.
My TekExpress
folder is
folder. The Untitled Session folder is deleted when you exit TekExpress.
CAUTIO
N. Each session has multiple les associated with it. Do not modify any of the session les and/or
folders as this may result in loss of data or corrupted session les.
The My
ID> My TekExpress name><user ID> My TekExpress
TekExpress
folder is created as a shared folder with share name as <domain><user
(or if the PC is not connected to domain then share name is <Computer
).
The above shared folder is mapped as X: (X drive) on to the PC where TekExpress is running.
NOTE. If X drive is mapped to any other shared folder, TekExpress will display a Warning message window asking to disconnect the X: drive manually.
Do the following before you click Run:
NOTE. Ensure that the network connectivity is enabled on the PC running the TekExpress.
1. Map (see page 14) the shared My TekExpress folder as X: (X drive) on all the instruments used
in test setup running Microsoft Windows Operating System. This share folder is used to save the waveform les or any other le transfer operations.
2. Rightclickonthe
My TekExpress folderandopentheProperties dialog box. Select General tab
and then Advanced.IntheAdvanced Attributes window, ensure that the option Encrypt contents to secure data is NOT selected. Click here
(see page 15) to view the picture.
TekExpress Serial ATA/SAS Automated Solutions 13
Getting Started Before You C lick Run
3. Ensure that the SATA/SAS setup les provided with TekExpress DVD are available on the respective instruments. For more details, refer to the folder on the T
ekExpress DVD.
ReadmeFirst.txt located in the SATA Setup Files
4. Ensure that all the required instruments are properly warmed up, Signal Path Compensation (SPC)
page 15) is perf
ormed, followed by cable deskew.
Mapping My TekExpress folder
To map the My TekExpress folder on the instruments, follow the steps below:
1. Open Windo
2. From the Windows Explorer menu, select Tools > Map Network drive.
3. Select the Drive letter as X: (if there is any previous connection on X:, disconnect it rst through Tools > Disconnect Network drive menu of Windows Explorer).
4. In the Folder eld, enter remote
John’s My TekExpress)
5. You can determine the IP address of the PC where “My TekExpress” folder exists by doing the following:
Select Start > Run menu on the PC where My TekExpress folder exists.
Enter cmd and click Enter.
At command prompt, type ipconfig.
ws Explorer.
My TekExpress folder path (for example, \\192.158.97.65\
(see
14 TekExpress Serial ATA/SAS Automated Solutions
Getting Started Before You Click Run
You ca n
1. On the oscilloscope main menu, click Utilities menu.
2. Click Instrument Calibration option.
nd SPC by following the steps below:
TekExpress Serial ATA/SAS Automated Solutions 15
Getting Started Before You C lick Run
16 TekExpress Serial ATA/SAS Automated Solutions

Operating Basics TekExpress Application Overview

TekExpress Application Overview

TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and future test automation needs. It is a highly modular architecture that enables deploying automated test solutions fo automation solution for the Serial ATA Gen 1, Gen 2, and Gen 3 standards.
Options available with TekExpress Serial ATA and SAS are:
r various serial standards in a relatively short time. TekExpress provides a compliance test
PHY/TSG/OOB Test Suite— Includes PHY-TSG-OOB test s tests.
PHY/TSG/OOB Test Suite — Includes PHY-TSG-OOB test suite SAS 2.0.
RSG-RMT Test Suite — Offers Phy Receiver Signal Requirements (RSG 1-2-3-5-6) and Receiver Margin Test (RMT) for SATA Gen1, Gen2, and Gen3
Rx-Tx Test Suite — Includes Rx-Tx test suite for Serial ATA Gen1, Gen 2, and Gen 3 tests.
RMT Test Suite — Offers Receiver Margin Test (RMT) for SAS 2.0.
Rx-Tx Test Suite — Includes Rx-Tx test suite for SAS 2.0.
TekExpress SATA Bundle for the Host and Drive Test Suites.
SI Cable Tests for TekExpress SATA — Includes SI test suite for SATA electrical cable assembly compliance test.

Key Features

The TekExpress provides the following salient features:
Complete SATA Gen1, Gen2, and Gen3 Test Coverage for Hosts, Drives and Cables.
PHY-TSG-OOB measurement for SAS 2.0.
uite Serial ATA Gen1, Gen2 and Gen3
Rx-Tx measurement for SAS 2.0.
Completely automated single button solution.
Signicant Reduction In Testing Time Through Automation.
Performs all (UTD 1.2, UTD 1.3, and UTD 1.4 conformant) SATA MOI required Transmitter, Receiver, and Channel measurements.
Single and Simple Microsoft Windows XP User Interface for Multi-instrument Testing.
Repeatable and accurate results.
Automatic HTML Report and SATA-IO (MS Excel) Scorecard Generation.
Receiver Margin Testing with High Performance Scan and Select Scan Parameter Preset methods.
Direct Synthesis and Device State Control Eliminates the Need for Multiple Sources.
TekExpress Serial ATA/SAS Automated Solutions 17
Operating Basics Starting the Application
PoweredbyNITestStand™.
Seamlessly Integrate with High-level TestStand Automation Layer.

Starting the Application

The application uses a USB dongle that contains the license key. This dongle must be present on the PC or the instrument hosting the TekExpress application.
The application also c hecks for a le, called is not found, instrument discovery is performed before launching TekExpress. The contains information regarding instruments available on network.
When the application starts, it checks for the appropriate license key. If the valid license key is not present, the application switches to the “Demo” mode. If the application fails to detect the dongle, it continues toruninDemomode.
To start the application, you can do one of the following:
Click Start > Programs > Tektronix > TekExpress > TekExpress Serial ATA & SAS.Other applications follow similar pattern.
Double-click the icon on the desktop.
If you have previously saved a session, double-click the session le stored under My
TekExpress\Serial ATA
When the application is launched it displays the splash screen providing launch information. The application also checks for the presence and validity of the USB dongle.
or M y TekExpress\SAS.
Resources.xml, located in My TekExpress folder. If this le
Resources.xml le
NOTE. If the application was not terminated properly during the last use, a dialog box asks to recall the previously unsaved session.
18 TekExpress Serial ATA/SAS Automated Solutions
Operating Basics Resizing the Application Window

Resizing the Application Window

To minimize the application, click on the application title bar. To restore the application to its
previous size, select
To maximize the application, click . To restore it to previous size, click on the application title bar.

Exiting the Application

To exit the application, do one of the following:
Click File > Exit.
Click on the application title bar.

Global Controls

The menus and controls that appear outside the individual tabs are called “Global Controls”. These are used to specify the devices to be tested.
in the Windows task bar.
Table 5: Controls a nd Functions
Control name Function
DUT
xxx
TekExpress Serial ATA/SAS Automated Solutions 19
The device ID is specied at the global level and the information is stored in the default location for all data les. This eld cannot be empty and does not allow these special characters (.,..,...,\,/:?”<>|*). The maximum length of characters allowed is 32.
This indicates whether your PC has enough memory to run and test a measurement, which is typically < 10 Gb.
You will be able to run, pause, resume and stop the tests.
Operating Basics File Menu

File Menu

Click File on the application menu bar.
The File menu has the following selections:
Menu Function
New Session Starts a default session of TekExpress.
Open Session Opens a saved session.
Save Session Saves the session.
Save Session As Saves a session in a different name.
Recently Recalled Setup Lists all the recent and previously recalled setup les.
Save Report As Saves the report in user specied location.
Print Preview Report
Print Report
Exit
xxx

View Menu

Click View on the application menu bar.
Previews the report before printing.
Opens the Windows “Print” dialog box.
Closes the application.
20 TekExpress Serial ATA/SAS Automated Solutions
Operating Basics Tool s Menu
The View menu has the following selections:
Menu Function
Log File
xxx
Opens the log (log.xml) le in the default viewer.

Tools Menu

Click Tools
on the application menu bar.
The Tools menu has the following selections:
Menu Function
Instrument Bench (see page 21) Opens a dialog box showing the list of instruments attached to the test setup.
E-mail Settings (see page 23) Opens a dialog box showing e-mail setting details.
Debug – Deskew Panel (see page 24) Opens a control panel that allows to control the RF-switch for debugging and
cable deskew.
xxx
> Instrument Bench
Tools
The Instrument Bench window shows the list of VISA and Non-VISA resources found on different
rfaces/connections. It serves two purposes at the launch of TekExpress:
inte
Discovers the connected instruments.
Conrms the instrument connection setup.
TekExpress Serial ATA/SAS Automated Solutions 21
Operating Basics Tools Menu
When you click Tools > Instrument Bench, the following dialog box is displayed:
Search Criteria: The various connections on which you can search. Non-VISA Resources are the instruments that cannot be searched using TekVISA.
Retrieved Instruments: Displays the count and details of instruments that were discovered.
Last Updated: Displays the time when the last time search was performed.
TekVISA Refresh Timeout (Seconds): This time o ut species the maximum time that TekExpress
can wait for TekVISA update.
NOTE. TekExpress uses TekVISA for instrument search. Ensure that TekVISA is running on your system before you refresh the instrument bench window.
Table 6: Retrieved Resources properties in the Instrument Bench window
Title Description
Connection Shows the type of connection with the instrument.
Resource
Serial Number Shows the serial number of the resource.
Options Shows the options available on the instrument.
Resource Address
xxx
1
The option column displays the options that tintheeld. To view complete options on the instrument, move the mouse cursor over the option.
Shows the name of the resource.
1
Shows IP Address/Port number of the resource.
22 TekExpress Serial ATA/SAS Automated Solutions
Operating Basics Tool s Menu
Table 7: Button controls on Instrument Bench dialog box
Button Function
Refresh The application searches on the selected connection for resources. While
searching res Discovery window shows the connection currently being scanned and the percentage of task completed.
ources it shows the Instrument Bench discovery window. The
Close Closes the
xxx
dialog box.
Tools > E-mail Settings
Use the E-mail Settings utility to congure and set the e-mail options. The following elds are mandatory for receiving e-mail notication from TekExpress:
1. Recipient Email Addresses. For example, User@domain.com.
2. Sender's Address.
3. SMTP Server address of the Mail server congured at client location.
If any of these elds are left blank, the settings are not saved and e-mail notication will not be sent.
Select the option “E-mail Test Results When Complete or on Error” has to be checked to receive the e-mail. The attachment list depends on what you have selected while conguring the e-mail setup.
NOTE. Among the e-mail attachments, the Analysis Screenshot is not yet functional.
TekExpress Serial ATA/SAS Automated Solutions 23
Operating Basics Tools Menu
Tools > Debug-Deskew Utility
The debug-deskew utility allows you to control the RF-switch state for setup debug purpose with primary objective to perform a real-time oscilloscope deskew the DUT TX terminals to the oscilloscope channels through the RF-switch. Using this utility, you can set the oscil various testing suites.
loscope deskew values that are retained by TekExpress SATA automation script throughout
(see page 24) operation for complex wiring path from
To ensure ac channels, it is important to rst deskew the oscilloscope channels before you take measurements of your DUT.
curate results for two-channel measurements and differential signals acquired on two
The Debug Deskew Utility has the following functions:
State: Sets the Open/Close state of the RF switch channels.
er the setup requirement, select the channels on the panel to be closed or opened. The previous
As p state of the RF switch is overridden by the new state. The current state of the RF Switch is not recalled
when the Debug panel is launched. Click applied on the selected RF Switch. The selection shown by LEDs on the RF Switch should be same
the selection shown on the panel.
as
Read Deskew/Attenuation Values: Reads the current Deskew values of the real time oscilloscope.
With the selected switch state, you are expected to manually perform the deskew (by removing SMA cable connection from TX terminals of CHS xture at DUT and reconnecting them to Fast-edge output
of the oscilloscope). Once the deskew values are set on the oscilloscope, click
and the current state as seen on the panel is
.The
24 TekExpress Serial ATA/SAS Automated Solutions
Operating Basics Help Menu
deskew values of all the four channels on the selected real time oscilloscope is read by TekExpress and are retained during test automation sequencing.
Set Deskew/Attenuation values: Click to restore the last values of deskew/attenuation. It is restored to the selected oscilloscope.
NOTE. The address of the instruments are passed to the panel on the current suite selection (as detected in instrument discovery). For example, in RX-TX and SI test suites, the Real Time Oscilloscope is not available and so it will not be passed. Only the address of the RF Switch is passed, if detected.
For more information on how to deskew real time oscilloscopes, refer to the section Deskew operation
(see page 99).

Help Menu

Click Help on the application menu bar.
The Help menu has the following selections:
Selection Description or Function
TekExpress Help
About TekExpress (see page 11 ) Displays application details such as software name, version
Activate License
x
xx
Displays TekExpress He lp (F1).
number and copyright.
Displays available software options and also about license activation.
TekExpress Serial ATA/SAS Automated Solutions 25
Operating Basics Help Menu
26 TekExpress Serial ATA/SAS Automated Solutions

How To Select the Test(s)

Select the Test(s)

The application tests the following three types of SATA devices and SAS Drive devices for compliance.
Drive
Host
Cable
The Select p
This panel provides the following functions:
anel allows you to select tests to congure and run.
Select Standard
Select the appropriate standard Serial ATA or SAS.
Select Device
Select the Device type. And the test suite options is automatically updated corresponding to the device selected.
TekExpress Serial ATA/SAS Automated Solutions 27
How To Select the Test(s)
Select Test Suite
The application allows you to select a subset of tests to execute. Based on the test suite selected, the Version drop-down list is populated.
Version
Select the appropriate version. For example, SATA Gen 1–UTD 1.2, SATA Gen 2–UTD 1.3, SATA Gen 2–UTD 1.
NOTE. The SI test suite for cable measurement does not have any versions.
4orSAS2.0.
The table
has the following two columns:
Select: You can include or exclude any test for analysis.
Tes t Na me : Displays the name of the test.
NOTE. If any of the check box in the Select column is grayed, you cannot make any changes. It implies that
t is mandatory.
the tes
Once you select a row, the following options are available:
Table 8: Select panel buttons
Button Description
Opens the conguration panel for the selected test.
Opens the PDF of method of implementation (MOI) for the selected test.
Opens the schematic for the selected test. This is useful if you want to verify the test setup before running the test.
Selects all tests in the table.
28 TekExpress Serial ATA/SAS Automated Solutions
How To Congure and Run the Test(s)
Table 8: Select p anel buttons (cont.)
Button Description
Selects all the SATA-IO required tests in the grid and deselects all informative tests in the table.
Deselects all tests in the table.
xxx
Congure and Run the Test(s)
Use the Conguration panel to create, view, and edit the parameters associated with the acquisition and the analysis of the selected test.
You have the following options:
To choose between running the tests in a Compliance or User Dened mode.
To reload compliance mode values.
To change the parameters associated with the conguration of acquisition.
To change the parameters associated with analysis conguration.
hange the test limits in User Dened mode.
To c
The upper half of the Congure panel has general parameters that are common for all the tests under the selected test suite that are editable. The lower half of the Congure panel has test specic parameters.
TekExpress Serial ATA/SAS Automated Solutions 29
How To Congure and Run the Test(s)
NOTE. If any of the test parameters are grayed, it means that these parameters cannot be modied in compliance mode. When you switch to user-dened mode, these parameters are editable.
Table 9: Test parameters
Parameters t
Acquire Parameters
Analyze parameters
oconfigure
Description
Shows the va related to acquisition of a selected test. These parameters can vary from one tes Number of Samples and Record Length.
Shows the various parameters related to analysis of a selected test. The Analyze parameters shows example of Jitter values, whereas the link points out JIT3 setup les.
rious parameters
t to another such as,
Limi
ts
Applies to a specic test. It shows the measurement limits using
erent types of comparisons.
diff
30 TekExpress Serial ATA/SAS Automated Solutions
How To View and Select Connected Instruments
Table 9: Test parameters (cont.)
Parameters to congure Description
Comments Species a comment up to 256
characters long for the selected test.
Complia
xxx
Click
nce settings
Run in the Select pane l to run the selected tests.
For the SAS standard, the Conguration panel works the same way.

View and Select Connected Instruments

ewing Connected Instruments
Vi
The Tools > Instrument Bench menu item is used to discover connected instruments required for the
sts. The application uses TekVISA to discover t he connected instruments. Once the operation is done,
te the Instrument Bench dialog box res umes operation and lists the instrument-related details based on t he selected search criteria.
Restores the compliance settings.
Saves all changes that you made.
Dismisses the dialog box and does not apply changes.
NOTE. When the TekVISA Instrument Manager checks for connected Instruments, the Instrument Bench dialog box does not respond.
TekExpress Serial ATA/SAS Automated Solutions 31
How To View and Select Connected Instruments
For example, if you select LAN as the search criteria intheInstrumentBenchdialogandclickRefresh, the TekVISA Instrument Manager checks for the instruments availability over LAN and the details of the instrumen
t are displayed under Retrieved Instruments table.
You c an p Instrument Manager does not nd the instruments, the TekExpress application resumes the operation.
If you c over the VISA layer can be searched.
rovide the time in the TekVISA Refresh Timeout (Seconds) eld, within which if the TekVISA
hoose Non-VISA resources, all the instruments supported by TekExpress but not communicating
Selecting Connected Instruments
You can view the instruments connected in the Conguration panel. The upper half of the panel displays the general parameters for the tests under the selected test suite.
Choose the instruments from the drop-down list as shown in the following gure:
32 TekExpress Serial ATA/SAS Automated Solutions
How To Use Prerecorded Waveforms for Analysis
Select th
NOTE. The list of instruments displayed is specic to the selected test suite. It does not show all the connected instruments.
e “Do Not Use” option in the drop-down list for those instruments which are optional.

Use Prerecorded Waveforms for Analysis

From the Acquire tab, you can see unique acquisitions, acquisition parameters, acquisition status, and prerecorded waveform les of the selected test suite. The Acquire panel is specic to a suite and gets
ted every time the selected test suite is changed. This panel shows the acquisition details for the tests
upda in the currently selected suite. The tests with the common acquisition parameters are grouped together and shown as a single acquisition.
NOTE. The acquire panel is disabled when the RSG-RMT test suite is selected. If you want to enable or disable “Use Pre- Recorded Waveform les”, select a test suite other than RSG-RMT to enable the acquire panel.
TekExpress Serial ATA/SAS Automated Solutions 33
How To Use Prerecorded Waveforms for Analysis
Column name Function
Acquisition Acquisition Name
Test
Status Test acquisition status of the running test passed at intervals.
Waveform File(s) Pre-recorded waveform les of unique acquisitions. You can select waveform
Name of the tests performing acquisitions. One or more test can perform the same acquisitions.
les by selecting browse waveform le using the standard le open window.
xxx
on individual cells. This allows you to select any
The following Acquire source options are available:
Use Pre-Recorded Waveform les: Enabling or disabling the option shows or hides the waveform le column in the acquisition table.
When you save a session and then select this option, the DUT ID text box changes to a drop-down list, in which you can select the DUT ID up to the point where the session was saved. A drop-down box appears above the Waveform le column, showing the run details, including the date and time of each run. If you select a run, corresponding data for that run is populated (such as the selected test, the test conguration settings, and the test summary status).
Acquire Step by Step: Selecting this prompts you at the end of each acquisition before proceeding to the next one.
Show Acquire Parameters: On enabling this option, the acquisition parameters for each unique acquisition is displayed in the acquisition table.
When you select “Use Pre-Recorded Waveform Files”, the rst column shows the waveform type and the second column shows the tests that use that waveform type for analysis. The following guidelines help you determine the correct prerecorded waveform for each test to be performed.
34 TekExpress Serial ATA/SAS Automated Solutions
How To Use Prerecorded Waveforms for Analysis
TIP. Select "Show Acquire Parameters" to verify the acquire parameters that are specied and the corresponding waveform.
Click the following links to get details on them:
Guidelines for PHY-TSG-OOB test suite waveforms
Each test requires a differential or single-endedwaveform. Forexample,asshowninthefollowinggure, the Unit Interval m easurement requires differential waveforms, and the Rise-fall time measurement requires single-ended waveforms. Some combinations require both single-ended and differential waveforms. You need to specify all required waveforms. The waveform le name must contain on the following (Diff), which are Single-Ended Positive (Pos), and which are Single-Ended Negative (Neg).
keywords: Diff, Pos, or Neg so that TekExpress can identify which waveforms are Differential
Guidel
Test suites such as Rx-Tx and SI need to have reference waveforms and waveforms with DUT. The acqui following folder location:
Refe
Location: X:\Serial ATA\Sampling Scope\TxRxScopeOperation
Naming Convention: Ref_<Acquire Type>_<Parameter1>_<Parameter2>_<Parameter3>_<Param-
eter4>_<Parameter5>_<Channel Pattern>.wfm
Example
1. Ref_MFTP-TDR Common_4000_300_4e-011_1e-011_Even_CH3+CH4.wfm
2. Ref_MFTP-TDR Differential_4000_300_4e-011_1e-011_Even_CH3-CH4.wfm
3. Ref_MFTP-TDR Single Ended_4000_300_4e-011_1e-011_Even_CH3.wfm
4.R
5. Ref_TDR Differential_4000_300_4e-011_1e-011_Even_CH1-CH2.wfm
6. Ref_TDR Single Ended_4000_300_4e-011_1e-011_Even_CH1.wfm
DUT waveforms
ines for Rx-Tx test suite waveforms
re panel allows you to specify only DUT waveforms. The reference waveforms are stored in the
rence Waveforms
:
ef_TDR Common_4000_300_4e-011_1e-011_Even_CH1+CH2.wfm
DUT waveforms need to be specied in TekExpress Acquire panel as described above. The le naming convention should be as follows:
Naming Convention: <Acquire Type> <Channel Pattern>
TekExpress Serial ATA/SAS Automated Solutions 35
How To Use Prerecorded Waveforms for Analysis
Acquire type and corresponding channel pattern:
Acquire type Channel patter
TDR Different
TDR Single En
TDR Common CH1+ CH2
MFTP - TDR Di
MFTP - TDR S
MFTP - TD R C
xxx
ial
ded
fferential
ingle Ended
ommon
CH1-CH2
CH1+ CH2
CH3-CH4
CH3, CH4
CH3+CH4
n
Examples:
TDR Differential_CH1-CH2_EUT.wfm
TDR Single Ended_CH1.wfm
User1_TDR Common_CH1+CH2.wfm
MFTP - TDR Differential_CH3-Ch4_Session1.wfm
MFTP - TDR Single Ended_CH4_Jan31.wfm
MFTP - TDR Common_CH3+Ch4.wfm
Guidelines for SI test suite waveforms
As mentioned in the guidelines for Rx-Tx test suite, the SI test suite also needs to have reference waveforms and waveforms with DUT. The acquire panel allows you to specify only DUT waveforms. The reference waveforms are stored in the following folder location:
Reference Waveforms
Location: X:\Serial ATA\Sampling Scope\SIScopeOperation
Naming Convention:
Ref/Ref_NoFixture_<Acquire Type>_<Parameter1>_<Parameter2>_<Parameter3>_<Parameter4>_<Pa­rameter5>_<Parameter6>_<Parameter7>_<Parameter_8>_<Channel Pattern>.wfm
Example
: Reference without fixture
Ref_NoFixture_TDR Differential_Odd_4000_128_5e-010_7e-011_5.5e-011_80_20_CH1-CH2.wfm
Ref_NoFixture_TDR Single Ended_Even_4000_128_5e-010_7e-011_5.5e-011_80_20_CH1.wfm
Ref_NoFixture_TDT CrossTalk_Odd_4000_128_3e-009_CH3-CH4.wfm
Ref_NoFixture_TDT Differential_Odd_4000_128_3e-009_CH5-CH6.wfm
Ref_NoFixture_TDR Common_Even_4000_128_5e-010_7e-011_5.5e-011_80_20_CH3+CH4.wfm
Example
: Reference with xture
Ref_TDR Common_Even_4000_128_5e-010_7e-011_5.5e-011_80_20_CH1+CH2.wfm
Ref_TDR Differential_Odd_4000_128_5e-010_7e-011_5.5e-011_80_20_CH1-CH2.wfm
36 TekExpress Serial ATA/SAS Automated Solutions
How To View the Progress of Analysis
Ref_TDR Single Ended_Even_4000_128_5e-010_7e-011_5.5e-011_80_20_CH4.wfm
DUT waveforms
DUT waveforms need to be specied in the TekExpress acquire panel. The le naming convention shouldbeasfollows:
Naming Convention: <Acquire Type>_<Channel Pattern>
Acquire type and corresponding channel pattern:
Acquire type Channel pattern
TDR Differential CH1-CH2, CH3-CH4, CH5-CH6, CH7-CH8
TDR Single Ended CH1, CH2, CH3, CH4
TDR Common CH1+CH2, CH3+CH4
TDT Differential CH5-CH6, CH7-CH8
TDT Crosstalk CH3-CH4, CH7-CH8
xxx
Examples:
TDR Differential_CH1-CH2_EUT.wfm
TDR Single Ended_CH1.wfm
1_TDR Common_CH1+CH2.wfm
User
TDT Differential_CH5-CH6_Session1.wfm
TDT Crosstalk_CH4_Jan31.wfm

ViewtheProgressofAnalysis

View the progress of the analysis in the Analyze panel. As the analysis of each test is complete, the result value is updated.
TekExpress Serial ATA/SAS Automated Solutions 37
How To View the Progress of Analysis
Analysi
The Analysis table contains the following:
The tests that are not yet started are shown with a “To be Started” status. A summarized status of the currently running test is shown on the Status Messages panel.
The Status Messages window timestamps all runtime messages and displays them. You can do the following:
NOTE. The Status Messages window is dockable and can be resized.
sTable
The test name.
The status of the tests that are being run.
Display Status: Enable/Disable status messages.
Auto Scroll: The status messages are scrolled automatically.
ear All: Clear all status messages in Status Window.
Cl
Save Status: Save all status messages in text le. Displays a standard save le window and saves the
atus messages in the user specied le.
st
38 TekExpress Serial ATA/SAS Automated Solutions
How To View the Report

View the Report

After the analysis, a report is automatically generated and displayed in the report panel. The report shows the results of the tests, including device information and pass/fa il status of each test.
The report displays the Device identication, the date and time that was run, and execution time. Test information like the Device Type, Version, Execution Time, Compliance Mode (Yes or No), and Overall Test Result the models, serial numbers, and rmware/software versions are shown. A table displays the Test Name, Measurement Details, Low, High limit values, Test Result, Analysis Execution time and so on.
The Report View Area contains an HTML version of the report template. You can select any area of the report and copy it to the clipboard to make it available to o ther application.
(Pass or Fail), MAC Address (in case of Receiver tests) are shown. Instrument information like
The View Scorecard option opens the report in Microsoft Excel
1
You must load Microsoft Excel 2002 before using the “View Scorecard” option.
1
.
TekExpress Serial ATA/SAS Automated Solutions 39
How To View Test Related Files

View Test Related Files

All the test related files for currently selected tests are always saved under My Documents\My
TekExpress\Serial ATA\Untitled Session
.
When you save a session, it is saved with the session name under the path
TekExpress\Serial ATA\SessionName
The session that is currently running is stored in the same path as “Untitled” until you save it.
WAR NING. Do not save a session named “Untitled” or “Backup” because there are application-specificles and ar
A session folder can contain results for more than o ne DUT, and a DUT folder can contain more than one run data f
Here is an example image of data storage:
e deleted when you exit the application.
older marked by date-time stamp as folder name.
for future references.
My Documents\My
40 TekExpress Serial ATA/SAS Automated Solutions

Application Examples for SATA RMT Equipment Setup: Drive

RMT Equipment Setup: Drive

You need the following equipment to set up the application:
Required equipment Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time Oscilloscope Tektronix DPO/DSA72004/B, DPO/DSA71604/B, DP O/DSA71254/B, and
DPO/DSA70804/B
MSO71254, MSO71604, MSO70804 and MSO72004
Scope based Error Detector is supported only on DPO/DSA 70000B and
MSO70000
RF Switch Keithley
Frame Error Analyzer
Test Fixture
Crescent
S46-6666A (Optional)
Heart Software SATA II and III probe adapter
Crescen
t Heart Software Test Fixture TF-SATA-NE-ZP
DUT
xxx
Wilder T
TF-SATA-TPA-PRC
ASATADrivetotest
est Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TekExpress Serial ATA/SAS Automated Solutions 41
Application Examples for SATA RMT Equipment Setup: Drive
Figure-1: Setup diagram for Drive RSG-RMT test suite with Scope based ED
NOTE. Click here
42 TekExpress Serial ATA/SAS Automated Solutions
for details on pin a ssignments.
Application Examples for SATA RMT-03-Gen3 (6.0GB/S) Receiver Margin Test

RMT-03-Gen3 (6.0GB/S) Receiver Margin Test

To run an RMT test on a Drive device, do the following:
1. Select Drive as the Device type, select RSG-RMT test suite and SATA Gen1 as the version.
2. Select RMT-03-Gen3 (6.0GB/S) Receiver Margin Test as the test to run and SATA Gen 1–UTD
1.4 as the version.
3. Click Show Schematic to view the setup diagram for the application.
4. Click Congure to congure the test parameters.
TekExpress Serial ATA/SAS Automated Solutions 43
Application Examples for SATA RMT-03-Gen3 (6.0GB/S) Receiver Margin Test
5. The defau Frequency and End Frequency. Click Save to save the new settings.
NOTE. The Value for the Frame Error Counter should be selected as “Do not use”.
6. Enter the DUT ID in the DUT eld of Select panel, and click Run.
7. The pro
lt settings are in User Dened Mode.Configure t he Analyze parameters, such as the Start
gress of the analysis is displayed in the Analyze tab.
44 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA PHY-TSG-OOB Equipment Setup: Drive
8. View the test result report in the Report panel.
PHY-TSG-OOB Equipment Setup: Drive
You need the following equipment to set up the application:
Required equipment Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time Oscilloscope Tektronix DPO/DSA72004/B, DPO/DSA71604/B, DPO/DSA71254/B,
TDS6154C, and TDS6124C
Tektronix MSO71254, MSO71604, and MSO72004
For Gen1-only testing, the following oscilloscopes are also acceptable:
DPO/DSA70804/B, TDS6804B or MSO70804
RF Switch Keithley S46-6666A (Optional)
Test F ixtu r e
DUT
xxx
Crescent Heart Software Test Fixture: TF-SATA-NE-ZP
Wilder Test Fixtures: TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
A SATA D rive to test
TekExpress Serial ATA/SAS Automated Solutions 45
Application Examples for SATA PHY-TSG-OOB Equipment Setup: Drive
Setup diagram for Drive PHY-TSG-00B test suite without RF switch
Setup diagram for Drive PHY-TSG-OOB test suite (without RF switch)
46 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA PHY-TSG-OOB Equipment Setup: Drive
Setup diagram for Drive PHY-TSG-00B test suite with RF switch
Setup diagram for Drive PHY-TSG-OOB test suite (with RF switch)
Connection guidelines.
For RF switch only: Do not connect the output of the signal source directly to the CHS xture. The signal must go through the RF switch.
For RF switch only: Terminate all unused RF switch outputs to 50 Ω.
The xture notations in the diagram are with reference to revision 1.0 of the CHS xture. If you are using xtures before revision 1.0, the xture notations are in reverse order.
If you are using Wilder xtures, click here for details on pin assignments.
If the DUT power cycle sequence is automated using DC output of the signal source, then do the following:
For 20-pin Molex connector of AT/ATX power supply, connect Channel 1 of the DC output
to pin 14, ground to pin 15.
For 24-pin Molex connector of AT/ATX power supply, connect Channel 1 of the DC output to pin 16, ground to pin 17.
TekExpress Serial ATA/SAS Automated Solutions 47
Application Examples for SATA PHY01 - Unit Interval Test
PHY01 - Unit Interval Test
To verify that the Unit Interval of the SATA Drive transmitter is within the conformance limit, follow these steps:
NOTE. The tes
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select the PHY-TSG-OOB as the Test Suite and SATA Gen 1–UTD 1.2 as the version.
3. Select PHY01 - Unit Interval.
4. Enter the DUT ID in the DUT eld.
5. If you wa
t procedure is same for both drive and host except for a change in the connection diagram.
nt to verify the test setup before running the test(s), click Show Schematic.
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mode.
48 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA PHY01 - Unit Interval Test
NOTE. The parameters that are not grayed are editable. To change the instrument related values, select from the drop-down list for each of the parameters.
7. You ca n c on gure any test to help you analyze measurement results. To refer to the Serial ATA Interoperability Program MOI document for information on how to congure the drive transmitter
click Show MOI in the Select panel.
tests,
8. Click Save to save the new settings for the selected test. If you want to restore the default settings,
Restore.
click
9. Click Run to run the selected tests.
10. The Acquire panel shows the status of the waveform acquisition.
TekExpress Serial ATA/SAS Automated Solutions 49
Application Examples for SATA PHY01 - Unit Interval Test
11. The status of the tests is displayed in the Analyze panel.
12. After the tests complete, a report is generated and d isplayed in the Report panel.
50 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA TSG02 - Rise-Fall Time Test without RF Switch
You can save the report using the File > Save Report As option.
TSG02 - Rise-Fall Time Test without RF Switch
To verify that the Rise/Fall time of the SATA Drive transmitter is within the conformance limits, follow these steps:
NOTE. Click here
NOTE. All cables must be d eskewed before performing this measurement.
1. Select Drive as the device type.
2. Sel
3. Enter the DUT ID in the DUT eld.
4. Select TSG02 - Rise-Fall Time.
5. If you want to verify the test setup before running the test(s), click Show Schematic.
ect PHY-TSG-OOB as the Test Suite and SATA Gen 1–UTD 1.2 as the v ersion.
(see page 45) for information on the drive test equipment setup.
TekExpress Serial ATA/SAS Automated Solutions 51
Application Examples for SATA TSG02 - Rise-Fall Time Test without RF Switch
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance mode.
NOTE. Th from the drop-down list for each of the param eters.
e parameters that are not grayed are editable. To change the instrument related values, select
7. You ca n c o n gure any test to help you analyze measurement results. To refer to the Serial ATA
nteroperability Program MOI document for information on how to congure the drive transmitter
I
tests, click Show MOI in the Select panel.
52 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA TSG02 - Rise-Fall Time Test without RF Switch
8. To run the test without using RF Switch, choose the Do not use option from the drop-down list for the RF switch parameter in the Congure panel.
9. Click Save to save the new settings for the selected test and click Close.
10. Click Run to run the selected tests.
11. The Acquire panel shows the status of the waveform acquisition.
12. The status of the tests is displayed in the Analyze panel.
13. After the tests complete, a report is generated and displayed in the Report panel.
TekExpress Serial ATA/SAS Automated Solutions 53
Application Examples for SATA OOB01 - OOB Signal Detection Threshold Test
OOB01 - OOB Signal Detection Threshold Test
To verify that the OOB Signal Detection Threshold of the SATA Drive receiver is within the conformance limits, follow these steps:
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select PHY-TSG-OOB as the Test Suite and SATA Gen 1-UTD 1.2 as the version.
3. Enter the DUT ID in the DUT eld.
4. Sel
5. If you want to verify the test setup before running the test(s), click Show Schematic.
ect the OOB01 - OOB Signal Detection Threshold option.
54 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA OOB01 - OOB Signal Detection Threshold Test
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mode.
7. If you want to change the parameters, choose User Dened Mode. The message reports that the
changes made to a test may no longer be compliant.
8. You ca n c on gure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program MOI document for information on how to congure the drive receiver tests,
click Show MOI in the Select panel.
9. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restore.
TekExpress Serial ATA/SAS Automated Solutions 55
Application Examples for SATA OOB01 - OOB Signal Detection Threshold Test
10. Click Run to run the selected tests.
11. The application automatically switches to the Acquire panel showing the waveform acquisition status.
12. The status of the tests is displayed in the Analyze panel.
13. After the tests complete, a report is generated and d isplayed in the Report panel.
56 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA OOB01 - OOB Signal Detection Threshold Test
TekExpress Serial ATA/SAS Automated Solutions 57
Application Examples for SATA RSG-RMT Equipment Setup: Drive
RSG-RMT Equipment Setup: Drive
You need the following equipment to set up the application:
Required equipment Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time Oscilloscope Tektronix DPO/DSA72004/B, DPO/DSA71604/B, DPO/DSA71254/B,
TDS6154C, and TDS6124C
MSO71254, MSO71604, and MSO72004
Scope based Error Detector is supported only on DPO/DSA 70000B and
MSO70000
For Gen1-o
DPO/DSA70804/B, TDS6804B or MSO70804
RF Switch Keithley S46-6666A (Optional)
Frame Er
Test Fi x
DUT
xxx
ror Analyzer
ture
Crescent Heart Software SATA II and III probe adapter
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
A SATA Drive to test
nly testing, the following oscilloscopes are also acceptable:
58 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA RSG-RMT Equipment Setup: Drive
Figure-2: Setup diagram for Drive RSG-RMT test suite with CHS
TekExpress Serial ATA/SAS Automated Solutions 59
Application Examples for SATA RSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group
NOTE. Click here for details on pin assignments.
RSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group
To run an RSG test on a SATA Drive to conformance standards dened by SATA-IO Interoperability, follow these steps:
NOTE. This test is applicable for both Drive and Host devices. The test procedure is the same for both drive and host ex
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select RSG-RMT as the Test Suite and SATA Gen 1 as the version.
cept for a change in the connection diagram. Refer to Figure 5
for Host connection diagram.
3. Enter the DUT ID in the DUT eld.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Selec
ttheRSG01-Gen1 (1.5Gb/s) Receiver Signalling Group option.
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mode.
60 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA RSG-01 - Gen1 (1.5Gb/s) Receiver Signalling Group
7. If you want to change the parameters, choose User Dened Mode. The message reports that the
changes made to a test may no longer be compliant.
8. You ca n c on gure any test to help you analyze measurement results. To refer to the Serial ATA
Interoperability Program, MOI document for information on how to congure the drive receiver tests,
click Show MO
9. Click Save to save the new settings for the selected test.
10. Click Run to run the selected tests.
The status of the tests is displayed in the Analyze panel.
I in the Select panel.
11. After the tests complete, a report is generated a nd displayed in the Report panel.
TekExpress Serial ATA/SAS Automated Solutions 61
Application Examples for SATA RMT- Receiver Margin Test
You can sa
ve the report using File > Save Report As option.
RMT- Receiver Margin Test
To run an RMT test on a Drive device, do the following:
1. Select Drive as the Device type, select RSG-RMT test suite and SATA Gen1 as the version.
2. Select RMT-01-Gen1 (1.5Gb/S) Receiver Margin Test as the test to run.
3. Click Show Schematic to view the setup diagram for the application.
NOTE. Refer to the Equipment Setup: Drive section for the setup diagram.
4. For information on how to congure the RMT test parameters, refer to RSG - RMT Method of Implementation document by clicking Show MOI.
62 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA RMT- Receiver Margin Test
5. Click Congure to congure the test parameters.
6. The default settings are in User Dened Mode.Congure the Analyze parameters, such as the Start Frequency and End Frequency. Click Save to save the new settings.
7. En
ter the DUT ID in the DUT eld of Select panel, and click Run.
8. The progress of the Analysis is displayed in the Analyze tab.
TekExpress Serial ATA/SAS Automated Solutions 63
Application Examples for SATA RMT- Receiver Margin Test
9. The test result report is displayed in the Report panel.
64 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA RSG-RMT Equipment Setup: Host
RSG-RMT Equipment Setup: Host
You need the following equipment to set up the application:
Required equipment Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Real Time Oscilloscope Tektronix DPO/DSA72004/B, DPO/DSA71604/B, DPO/DSA71254/B, TDS6154C,
and TDS6124
C
Tektronix M
Scope base
MSO70000
For Gen1-only testing, the following oscilloscopes are also acceptable:
DPO/DSA70804/B, TDS6804B or MSO70804
RF Switch Keithley S46-6666A (Optional)
Frame Error Analyzer
Test Fixture
DUT
xxx
Crescent Heart Software SATA II and III probe adapter
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and TF-SATA-TPA-PRC
A SATA Host to test
SO71254, MSO71604, and MSO72004
d Error Detector is supported only on DPO/DSA70000B and
TekExpress Serial ATA/SAS Automated Solutions 65
Application Examples for SATA RSG-RMT Equipment Setup: Host
Figure-3: Setup diagram for Host RSG-RMT test suite with CHS
66 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA RSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group
NOTE. Click here for details on pin assignments.
RSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group
To run a RSG test on a SATA Host to conformance standards dened by SATA-IO Interoperability, follow these steps:
NOTE. The test procedure is the same for both drive and host except for a change in the connection diagram. R
NOTE. All cables must be d eskewed before performing this measurement.
1. Select Host as the device type.
2. Select RSG-RMT test suite and SATA Gen 2-UTD 1.2 as the version.
efer to Figure 4
for the Drive connection diagram.
3. Enter the DUT ID in the DUT eld.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Select the RSG-02 Gen2 (3.0Gb/s) Receiver Signalling Group.
6. Click Congure ifyouwanttocongure the test parameters. Observe that the default settings are
in Compliance mode.
7. If you want to change the parameters, choose User Dened Mode.
TekExpress Serial ATA/SAS Automated Solutions 67
Application Examples for SATA RSG-02 - Gen2 (3.0Gb/s) Receiver Signalling Group
8. You ca n c o n gure any test to help you analyze measurement results. To refer to the Serial ATA Interoperability Program MOI for information on how to congure the host receiver tests, click
Show MOI in the
9. Click Save to save the new settings for the selected test. If you want to restore the default settings,
click Restor
Select panel.
e.
10. Click Run to run the selected tests. The status of the tests is displayed in the Analyze panel.
11. After the tests run successfully, a report is generated and displayed in the Report panel.
68 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA Rx-Tx Equipment Setup: Drive
You can save the report using File > Save Report As menu option.
Rx-Tx Equipment Setup: Drive
Resource Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8) or AWG7102 (Option 1, 6)
Sampling Oscilloscope Tektronix CSA/TDS/DSA 8200 with two 80E04/80E10 modules
RF Switch Keithley S46-6666A (Optional)
Fixture
Test
SMA Cables Five pair of matched SMA Cables – 179-4944-00 or equivalent
Attenuators Four 6 dB attenuators
T
DU
xxx
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
One SMA cable to connect to trigger input
One SMA barrel adapter
ASATADrivetotest
TekExpress Serial ATA/SAS Automated Solutions 69
Application Examples for SATA Rx01 - Pair Differential Impedance test
Figure-4: Setup diagram for Drive RXTX test suite
NOTE. Click here
for details on pin a ssignments.
Rx01 - Pair Differential Impedance test
To verify that the Pair Differential Impedance of the SATA Drive receiver is within the conformance limits, follow these steps:
70 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA Rx01 - Pair Differential Impedance test
NOTE. This test is applicable for both Drive and Host devices. The test procedure is the same for both drive and host except for a change in the connection diagram. Click here the drive test
1. Select Drive as the device type.
2. Select RX-TX as the Test Suite and SATA Gen 1-UTD 1.2 as the version.
3. Enter the DUT ID in the DUT eld.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
equipment setup.
(see page 45) for information on
5. Select Rx-
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mode.
01 – Pair Differential Impedance.
NOTE. The parameters that are not grayed are editable. To change the instrument related values, select from the drop-down list for each of the parameters.
7. You ca n c on gure any test to help you analyze measurement results. To refer to the Serial ATA Interoperability Program document for information on how to congure the drive receiver tests,
lick Show MOI in the Select panel.
c
8. Click Save to save the new settings for the test selected. If you want to restore the default settings, click Restore.
TekExpress Serial ATA/SAS Automated Solutions 71
Application Examples for SATA Rx01 - Pair Differential Impedance test
9. Click Run to run the selected tests.
10. The Acquire panel shows the waveform acquisition status.
11.Th
e status of the tests is displayed in the Analyze panel.
72 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA Rx-Tx Equipment Setup: Host
12. After the tests complete, a report is generated and displayed in the Report panel.
Rx-Tx Equipment Setup: Host
Resource Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8) or Tektronix AWG7102 (Option 1, 6)
Sampling Oscilloscope Tektronix CSA/DSA/TDS 8200 with two 80E04/80E10 modules
RF Switch Keithley S46-6666A (Optional)
TekExpress Serial ATA/SAS Automated Solutions 73
Application Examples for SATA Rx-Tx Equipment Setup: Host
Resource Supported mode
Test Fi x t ur e
Crescent Hear
Wilder Test Fi
l
t Software Test Fixture TF-SATA-NE-ZP
xtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-TPA-PRC
SMA Cables Five pair of matched SMA Cables – 179-4944-00 or equivalent
One SMA cable to connect to trigger input
One SMA barrel adapter
Attenuator
DUT
xxx
s
Two6dBatte
ASATAHost
nuators
to test
Figure-5: Setup diagram for Host RXTX test suite
74 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA Rx03 - Differential Mode Return Loss
NOTE. Click here for details on pin assignments.
Rx03 - Differential Mode R eturn Loss
To verify that the Differential Mode Return Loss of the SATA Host receiver is within the conformance limits, follow these steps:
NOTE. This test is applicable for both Drive and Host devices. The test procedure is identical for both drive and host ex
1. Select Host as the device type.
2. Select RX-TX as the Test Suite and SATA Gen 2-UTD 1.2 as the version.
3. Enter the DUT ID in the DUT eld.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
cept for a change in the connection diagram. Refer to Figure 6
for Drive connection diagrams.
5. Select Rx06 - Differential Mode Return Loss.
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mode.
7. If you want to change the parameters, choose User Dened Mode. The message reports that the changes made to a test may no longer be compliant.
TekExpress Serial ATA/SAS Automated Solutions 75
Application Examples for SATA Rx03 - Differential Mode Return Loss
8. You ca n c o n gure any test to help you analyze measurement results. To refer to the Serial ATA Interoperability Program MOI document for information on how to congure the host receiver tests,
click Show MOI
9. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restor
in the Select panel.
e.
10. Click Run to run the selected tests.
11. The application automatically switches to the Acquire panel. The status of the waveform acquisition is
displayed in this panel.
76 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA Rx03 - Differential Mode Return Loss
12. The status of the tests is displayed in the Analyze panel.
13. After the tests complete, a report is generated and displayed in the Report panel.
You can save the report using File > Save Report As option.
TekExpress Serial ATA/SAS Automated Solutions 77
Application Examples for SATA SI Equipment Setup

SI Equipment Setup

Resource Supported model
Sampling Oscilloscope Tektronix CSA/DSA/TDS 8200 with four 80E04/80E10 modules
Test Fi x t ur e
SMA Cables Four pairs of matched SMA Cables 179-4944-01 or equivalent
DUT
xxx
Connect t
he equipment as shown in the following diagram:
Two Crescent Heart Software Fixture TF-SATA-FE-ZP
Two SMA barrel adapters
A SATA Cable to test
gure-6: Setup diagram for Cable SI test suite
Fi
NOTE. Click here for details on pin assignments.
78 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA SI-02 - Cable Absolute Differential Impedance test on a SATA Cable
SI-02 - Cable Absolute Differential Impedance test on a SATA Cable
To run an SI test on a SATA Cable to conformance standards dened b y SATA-IO Interoperability, follow these steps:
NOTE. This te
1. Select Cable as the device type.
2. Select SI as the Test Suite.
NOTE. There is no test suite version for an SI test.
3. Enter the DUT ID in the DUT eld.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Select the SI-02 – Cable Absolute Differential Impedance.
st is applicable only for SATA cables.
ick Congure to congure the test parameters. Observe that the default settings are in Compliance
6. Cl
mode.
f you want to change the parameters, choose User Dened Mode. The message reports that the
7.I
changes made to a test may no longer be compliant.
TekExpress Serial ATA/SAS Automated Solutions 79
Application Examples for SATA SI-02 - Cable Absolute Differential Impedance test on a SATA Cable
8. You ca n c o n gure any test to help you analyze measurement results. To refer to the Serial ATA Interoperability Program MOI document for information on how to congure the cable tests, click
Show MOI in the Select panel.
9. Click Save to save the new settings for the test selected. If you want to restore the default settings, click Restore.
10. Click Run to run the selected tests.
11. The application aut
acquisition.
omatically switches to the Acquire panel. This shows the status of the waveform
80 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SATA SI-02 - Cable Absolute Differential Impedance test on a SATA Cable
12. On completion of the acquisition, the application switches to the Analyze panel. This panel shows the status of the analysis.
13. After the tests run successfully, a report is generated and displayed in the Report panel.
You can save the report using the File > Save Report As option.
TekExpress Serial ATA/SAS Automated Solutions 81
Application Examples for SATA SI-02 - Cable Absolute Differential Impedance test on a SATA Cable
82 TekExpress Serial ATA/SAS Automated Solutions

Application Examples for SAS PHY-TSG-OOB Drive Test Equipment Setup

PHY-TSG-OOB D
Click here (s
ee page
rive Test Equipment Setup
45) for information on the drive test equipment setup.
TekExpress Serial ATA/SAS Automated Solutions 83
Application Examples for SAS Test 5.2.1-Tx SSC Modulation Type Test
Test 5.2.1-Tx SSC Modulation Type Test
Click here (see page 45) for information on the drive test equipment setup.
To verify that the 5.2.1-TX SSC Modulation Type of the SAS Drive transmitter is within the conformance limit, follow these steps:
NOTE. All cables must be deskewed before performing this measurement.
1. Select Drive as the device type.
2. Select the PHY-TSG-OOB as the Test Suite and SAS 2.0 as the version.
3. Select Test 5.2.1-Tx SSC Modulation Type.
4. Enter the DUT ID in the DUT eld.
5. If you wa
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mode.
nt to verify the test setup before running the test(s), click Show Schematic.
NOTE. The parameters that are not grayed are editable. To change the instrument related v alues, select from the drop-down list for each of the param eters.
84 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SAS Test 5.2.1-Tx SSC Modulation Type Test
7. You c a n c o n gure any test to help you analyze measurement results. To refer to the SAS Interoperability Program MOI document for information on how to congure the drive transmitter
tests, click S
8. Click Save to save the new settings for the selected test. If you want to restore the default settings, click Restore.
how MOI in the Select panel.
9. Click Run to run the selected tests.
10. The Acquire panel shows the status of the waveform acqu
11. The status of the tests is displayed in the Analyze panel.
isition.
TekExpress Serial ATA/SAS Automated Solutions 85
Application Examples for SAS Test 5.2.1-Tx SSC Modulation Type Test
12. After the tests complete, a report is generated and d isplayed in the Report panel.
can save the report using the File > Save Report As option.
You
86 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SAS Rx-Tx Equipment Setup: Drive
Rx-Tx Equipment Setup: Drive
Resource Supported model
Signal Source Tektronix AWG7122B (Option 1, 6, 8)
Sampling Oscilloscope Tektronix CSA/TDS/DSA 8200 with two 80E04/80E10 modules
RF Switch Keithley S46-6666A (Optional)
Test F ixtu r e
SMA Cable
s
Crescent Heart Software Test Fixture TF-SATA-NE-ZP
Wilder Test Fixtures TF-SATA-TPA-P, TF-SATA-TPA-R, and
TF-SATA-T
Five pair
PA- PRC
of matched SMA Cables – 179-4944-00 or equivalent
One SMA ca
One SMA ba
Attenuators Four 6 dB attenuators
DUT
xxx
A SAS Drive to test
ble to connect to trigger input
rrel adapter
TekExpress Serial ATA/SAS Automated Solutions 87
Application Examples for SAS Rx-Tx Equipment Setup: Drive
Figure-7: Setup diagram for Drive RXTX test suite
NOTE. Click here
88 TekExpress Serial ATA/SAS Automated Solutions
for details on pin a ssignments.
Application Examples for SAS Test 5.4.2-RX Common-Mode Return Loss (SCC11)
Test 5.4.2-RX Common-Mode Return Loss (SCC11)
To verify that the Rx Common-Mode Return Loss of the SAS Drive transmitter is within the conformance limit, follow these steps:
1. Select Drive as the device type.
2. Select RX-TX as the Test Suite and SAS 2 .0 as the version.
3. Enter the DUT ID in the DUT eld.
4. If you want to verify the test setup before running the test(s), click Show Schematic.
5. Select Te s
6. Click Congure to congure the test parameters. Observe that the default settings are in Compliance
mod
t 5.4.2-RX Common-Mode Return Loss (SCC11).
e.
NOTE. The parameters that are not grayed are editable. To change the instrument related values, select from the drop-down list for each of the parameters.
7. You c a n c o n gure any test to help you analyze measurement results. To refer to the SAS Interoperability Program document for information on how to congure the drive receiver tests,
click Show MOI in the Select panel.
8. Click Save to save the new settings for the test selected. If you want to restore the default settings,
click Restore.
TekExpress Serial ATA/SAS Automated Solutions 89
Application Examples for SAS Test 5.4.2-RX Common-Mode Return Loss (SCC11)
9. Click Run to run the selected tests.
10. The Acquire panel shows the waveform acquisition status.
11. The status of the tests is displayed in the Analyze panel.
90 TekExpress Serial ATA/SAS Automated Solutions
Application Examples for SAS Test 5.4.2-RX Common-Mode Return Loss (SCC11)
12. After the tests complete, a report is generated and displayed in the Report panel.
TekExpress Serial ATA/SAS Automated Solutions 91
Application Examples for SAS Test 5.4.2-RX Common-Mode Return Loss (SCC11)
92 TekExpress Serial ATA/SAS Automated Solutions
Loading...