TDS 600C Features
Most TDS 600B information in the TDS 500D, TDS 600B, & TDS 700D
Digitizing Oscilloscopes User manual is valid for the TDS 654C, TDS 680C,
and TDS 684C oscilloscope models. This supplement lists the differences
between the TDS 600C and the TDS 600B models.
Key Features
Except for the differences outlined in this manual, the TDS 600C is identical to a
TDS 600B. Most of the information in your user manual (and other TDS
documentation) that applies to the TDS 600B also applies to the TDS 600C.
Table 1 lists the key features of the oscilloscope models. The pages that follow
list the new TDS 600C features.
Table 1: Key Features and differences of models
Feature520D540D580D654C680C684C724D754D784D794D
No. of channels2+2
1
4442+2
1
42+2
1
444
Digitizing rate, max.2 GS/s4 GS/s5 GS/s2 GS/s4 GS/s
No. of Channels. at max-
imum rate
Analog Bandwidth500 MHz1GHz500 MH
Record Lengths, max.To 50K/Channel
DPO AcquisitionsYesNoYes
Hi Res AcquisitionsYesNoYes
Advanced DSP Math
Communication Signal
Analyzer
Reference ReceiverOption 3C and 4CNoOption 3C and 4CNo
3
121424121
1GHz500 MHz1GHz2GHz
z
2
Option 2FStandard
Option 2CNoOption 2C
To 15K/ChannelTo 50K/Channel
4
2
TDS 500D, TDS 600C & TDS 700D Supplement
1
TDS 600C Features
Table 1: Key Features and differences of models (Cont.)
Two plus Two channel operation allows two of four channels to be displayed simultaneously. Channels not displayed can
be used to couple a triggering signal to the oscilloscope.
2
These TDS models can be purchased with Option 1M or Option 2M, which add longer record length settings (up to
2 Mb/channel). See Option 1M and Option 2M on pages 4 and 5.
3
Advanced digital signal processing provides FFTs, integrals, and derivatives of waveforms. See Option 2F on page 5.
4
Standard denotes a standard product feature as opposed to a feature included as part of an option.
5
GPIB I/O included with all models.
Display Histograms
The TDS 600C can display histograms as described in the TDS 500D, TDS 600B
& TDS 700D Digitizing Oscilloscopes User Manual.
Select an Application
The TDS 600C can select and load Java-based applications in the APPLICATION menu as described in the TDS 500D, TDS 600B & TDS 700D DigitizingOscilloscopes User Manual. Then you can control the application using the
APPLICATION menus.
2
TDS 500D, TDS 600C & TDS 700D Supplement
TDS 600C Features
Option HD
Iomega Zip Drive Support
Display Measurement
Statistics
Take Optical
Measurements
External Attenuation
Probe Calibration
If your TDS 600C contains the optional hard disk, you can use it to save and
recall waveforms, setups, and hard copies as described in the TDS 500D,TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual. With this
option, you can also run Java-based application programs.
The TDS 600C is compatible with Iomega 100 Mbyte Zip drives as described in
the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
The TDS 600C can display statistics about a measurement as described in the
TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
The TDS 600C can take Extinction Ratio, Extinction Percent, Extinction dB, and
Mean dBm measurements as described in the TDS 500D, TDS 600B &TDS 700D Digitizing Oscilloscopes User Manual.
The TDS 600C can set External Attenuation as described in the TDS 500D,TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
On the TDS 600C, use the TDS 500D and TDS 700D procedures to calibrate a
probe as described in the TDS 500D, TDS 600B & TDS 700D DigitizingOscilloscopes User Manual.
TDS 500D, TDS 600C & TDS 700D Supplement
3
TDS 600C Features
Options
Tektronix will ship the options shown in Table 2:
Table 2: Options
Option #LabelDescription
A1Universal European
power cord
A2UK power cord240 V, 50 Hz power cord
A3Australian power cord240 V, 50 Hz power cord
A4North American power
cord
A5Switzerland power cord220 V, 50 Hz power cord
HDHard disk driveAddaharddisk.
05Video triggerOscilloscope comes with tools for investigating events that occur when a video signal
1KScope cartK420 scope cart. This cart can help transport the oscilloscope around many lab environ-
1M
130,000 record length
220 V, 50 Hz power cord
240 V, 60 Hz power cord
generates a horizontal or vertical sync pulse. These tools allow investigation of a range of
NTSC, PAL, SECAM, and high definition TV signals. (Option is not available on the
TDS 794D.)
Add RS-232-C and Centronics interface ports.
(Option applies to TDS 500D only.)
(Option applies to TDS 520D, TDS 540D, TDS 724D, and TDS 754D only.)
ments.
Extend record length from 50,000 samples standard as follows:
TDS 520D and TDS 724D: To 250,000 samples on one channel and 130,000 on two
channels
TDS 540D, TDS 580D, TDS 754D, TDS 784D, and TDS 794D: To 500,000 samples on one
channel, 250,000 on two channels, and 130,000 samples on three or four channel s
(Option is only available for the models listed above.)
4
TDS 500D, TDS 600C & TDS 700D Supplement
Table 2: Options (cont.)
Option #DescriptionLabel
TDS 600C Features
2M
1RRackmountOscilloscope comes configured for installation in a 19 inch
34Differential probeAdda1GHz(probeonly)P6247 differential probe
35Active probeAdda1GHz(probeonly)P6243 active probe
36Passive probeAdd a 500 MHz P6139A 10X passive probe
37Active probeAdd a 1.5 GHz P6245 active probe
2F
8 M acquisition length
Communication Signal
Analyzer
calibration
calibration
Advanced DSP math
Extend standard acquisition length as follows:
TDS 520D and TDS 724D: To 2 M samples on two channels and 4 M on one channel
TDS 540D, TDS 580D, TDS 754D, TDS 784D, & TDS 794D: To 2 M samples on three or
four channels, 4 M on two channels, and 8 M samples on one channel
(Option includes a hard disk and is only available for the models listed above.)
wide instrument rack. For later field conversions, order kit # 016-1236-00.
Oscilloscope comes configured for communications signal triggering and mask testing.
(Option applies to TDS 500D & TDS 700D only.)
Oscilloscope comes with a P6701B and calibrated short-wavelength optical reference
receiver on channel 1. (Option applies to TDS 500D & TDS 700D only, except TDS 794D.)
Oscilloscope comes with a P6703B and calibrated long-wavelength optical reference
receiver on channel 1. (Option applies to TDS 500D & TDS 700D only, except TDS 794D.)
(Option applies only to TDS 794D.)
(Option applies only to TDS 794D.)
(Option applies only to TDS 580D, TDS 680C, TDS 684C, TDS 784D, and TDS 794D.)
(Option applies only to TDS 754D, TDS 724D, TDS 540D, and TDS 520D.)
(Option applies only to TDS 784D, TDS 600C, and TDS 580D.)
(Option applies only to TDS 794D, TDS 784D, TDS 680C, TDS 684C, and TDS 580D.)
Add advanced DSP math features such as FFT, integration, and differentiation.
(Option applies only to TDS 500D models.)
TDS 500D, TDS 600C & TDS 700D Supplement
5
TDS 600C Features
Table 2: Options (cont.)
Option #DescriptionLabel
C3Three years calibrationProvides three years of calibration
C5Five years calibrationProvides five years of calibration
D1Calibration data reportOscilloscope comes with a calibration data report.
D3Calibration data for C3Provides calibration data for option C3
D5Calibration data for C5Provides calibration data for option C5
R5Extended WarrantyOscilloscope comes witha5yearextended warranty.
L1
Manuals in French
Provides Language versions of User Manual, according to option number chosen.
L3
L5
L9
Manuals in German
Manuals in Japanese
Manuals in Korean
Standard Accessories
The oscilloscope comes standard with the accessories listed in Table 3.
Table 3: Standard accessories
AccessoryPart number
User Manual with Programmers Manual Help Disk071-0130-XX
Reference020-2313-XX
Technical Reference: Performance Verification and Specifications071-0630-XX
Probes:
TDS 754D and TDS 540D:
Four P6139A 10X, 500 MHz Passive probes
TDS 654C: Four P6243 1 GHz Active probes
TDS 724D and TDS 520D:
1000XP6015AP6015AP6015AP6015AP6015AP6015A
SMDP6563AP6563AP6563AP6563AP6563AP6563A
Low CapacitanceP6158P6158P6158P6158
Active CMOS/TTLP6243P6245P6243P6245P6243P6245P6245
Active, High BandwidthP6245
Le présent document s’applique aux versions matérielles 5.1 et ultérieures.
Copyright Tektronix, Inc. Tous droits réservés.
Les produits Tektronix sont protégés par des licences américaines et étrangères, publiées et en attente de publication.
Les informations contenues dans le présent manuel remplacent et annulent toute documentation publiée antérieurement.
Les changements de spécifications et de prix sont sous réserve.
Imprimé aux Etats-Unis.
Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000
TEKTRONIX, TEK et TEKPROBE sont des marques déposées de Tektronix, Inc.
Fonction du TDS 600C
La plupart des informations concernant le TDS 600B dans le Manuel d’utilisation des oscilloscopes numériques TDS 500D, TDS 600B & TDS 700D sont aussi
valables pour les modèles TDS 654C, TDS 680C et TDS 684C. Ce supplément
présente les différences qui existent entre les modèles TDS 600C et TDS 600B.
Fonctions principales
Hormis les différences soulignées dans le présent manuel, le TDS 600C est
identique au TDS 600B. La plupart des informations contenues dans le manuel
d’utilisation (et autre documentation TDS) qui s’appliquent au TDS 600B
s’appliquent également au TDS 600C.
Le Tableau 1 contient une liste des fonctions principales des modèles d’oscilloscope. Les pages qui suivent présentent les nouvelles fonctions du TDS 600C.
Table 1: Fonctions principales et différences entre modèles
Fonction520D540D580D654C680C684C724D754D784D794D
Nombre de voies2+2
1
4442+2
1
42+2
1
444
Vitesse de numérisation, maxi.
Nombre de voies à
débit maximal
Bande passante analogique
Longueurs d’enregistrement, maxi.
Acquisitions DPOOuiNonOui
Acquisitions Hi ResOuiNonOui
DSP évoluée
Analyseur de signaux
de transmission
Récepteur de référenceOption 3C et 4CNonOption 3C et 4CNon
Le mode deux plus deux voies permet d’afficher simultanément deux des quatre voies. Les voies qui ne sont pas
affichées peuvent servir à coupler un signal de déclenchement sur l’oscilloscope.
2
Il est possible d’acquérir ces modèles TDS avec l’Option 1M ou l’Option 2M, qui permettent des longueurs
d’enregistrement plus grandes (jusqu’à 2 Mo/voie). Voir Option 1M et Option 2M aux pages 4 et 5.
3
Le traitement évolué des signaux numériques permet le calcul de FFT, d’intégrales et de dérivés de signaux. Voir Option
2Fàlapage5.
4
Le qualificatif « standard » désigne les fonctions standard par opposition aux fonctions faisant partie d’une option.
5
Tous les modèles sont dotés d’une E/S GPIB.
Standard
Standard
Couleur
chrome
Afficher des
histogrammes
Le TDS 600C peut afficher des histogrammes comme cela est expliqué dans le
Manuel d’utilisation des oscilloscopes numériques TDS 500D, TDS 600B &
TDS 700D.
Sélectionner une
application
Le TDS 600C permet la sélection et le chargement d’applications Java dans le
menu APPLICATION, comme cela est décrit dans le Manuel d’utilisation desoscilloscopes numériques TDS 500D, TDS 600B & TDS 700D.L’opérateur peut
ensuite contrôler l’application à l’aide des menus APPLICATION.
Si votre TDS 600C est équipé du disque dur disponible en option, vous pouvez
utiliser celui-ci pour sauvegarder et rappeler des signaux, des configurations,
ainsi que pour faire des sorties imprimées, conformément aux instructions du
Manuel d’utilisation des oscilloscopes numériques TDS 500D, TDS 600B &
TDS 700D. Avec cette option, vous pouvez également utiliser des programmes
d’application Java.
Le TDS 600C est compatible avec le lecteur de disquettes Zip Iomega de
100Mo, comme cela est expliqué dans le Manuel d’utilisation des oscilloscopesnumériques TDS 500D, TDS 600B & TDS 700D.
Le TDS 600C peut afficher des statistiques relatives à une mesure, comme cela
est expliqué dans le Manuel d’utilisation des oscilloscopes numériquesTDS 500D, TDS 600B & TDS 700D.
Le TDS 600C peut effectuer des mesures de rapport d’extinction, de pourcentage
d’extinction, de dB d’extinction et de moyenne de dBm, comme cela est
expliqué dans le Manuel d’utilisation des oscilloscopes numériques TDS 500D,TDS 600B & TDS 700D.
Atténuation externe
Etalonnage des sondes
Le TDS 600C peut définir l’Atténuation externe conformément à la description
fournie dans le Manuel d’utilisation des oscilloscopes numériques TDS 500D,TDS 600B & TDS 700D.
Sur le TDS 600C, utilisez les procédures TDS 500D et TDS 700D pour
étalonner les sondes conformément à la description fournie dans le Manuel
d’utilisation des oscilloscopes numériques TDS 500D, TDS 600B & TDS 700D.