Tektronix TDS5052B Data Sheet

Digital Phosphor Oscilloscopes
TDS5000B Series
The World’s Easiest to Use Midrange Oscilloscope
MyScope Custom Control Windows
The TDS5000B Series offers the industry’s
first easily customizable oscilloscope user
interface. MyScope control windows is a
revolutionary new feature that allows you
to build your own control windows with
only the controls, features, and capabilities
that you care about and are important in your
job. For the first time, you can pull all the
functionality you need from all the various
parts of the oscilloscope into one control
window, effectively creating your own per-
sonalized “toolbox” of oscilloscope features.
No longer do you need to search through
menus for features or re-learn how to drive
the oscilloscope after a break from the lab.
MyScope control windows enable you to
spend your valuable time focused on the
task at hand rather than navigating menus
on your oscilloscope. And creating these
custom control windows isn’t a long drawn-
out or complex process. They are easily
created in a matter of minutes using a
simple, visual, drag and drop process. Once
created, these custom control windows
are easily accessed through a dedicated
MyScope button and menu selection on the
oscilloscope button/menu bar, just like any
other control window. You can make an
unlimited number of custom control windows,
enabling each person who uses the oscillo-
scope, in a shared environment, to have
their own unique control window. Since the
Features & Benefits
1 GHz, 500, 350 MHz Bandwidth Models
2 and 4 Channel Models
5 GS/s Sample Rate
Up to 16 M Record Length
100,000 wfms/s Maximum Waveform Capture Rate
Right Mouse Click Menus for Exceptional Efficiency
OpenChoice®Platform with Windows 2000 Delivers Built-in Networking and Analysis
Small Footprint/Light Weight
10.4 in. Bright Display
Suite of Advanced Triggers
Communication Mask Testing
Pass/Fail Limit Testing
Remote Viewing and Control
E-mail on Event
CD-RW Drive
Built-in Printer (Optional)
Interoperability with Tektronix Logic Analyzers
GPIB Controller
Custom
Applications
Digital Design and Debug
Mask Testing for Telecomm/ Datacomm/Video Standards
Investigation of Transient Phenomena
Power Measurements
Video Design and Debug
DVD, Jitter and Timing, Spectral Analysis
Automotive Electronics
Manufacturing Test
Electro-mechanical
Bio-medical
Industrial Control
1
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
Digital Phosphor Oscilloscopes
TDS5000B Series
control windows are stored as files on the
hard drive, they can easily be transferred
to other TDS5000B Series oscilloscopes, or
they can even be e-mailed to a co-worker
around the world when the need arises.
MyScope control windows will benefit all
oscilloscope users, from eliminating the
ramp-up time that many face when returning
to the lab after not using an oscilloscope for
a while, to the power user who can now
operate far more efficiently. Everything you
need is found in one control window rather
than having to constantly navigate through
menu after menu to repeat similar tasks.
Right Clicks
The TDS5000B also introduces a compre-
hensive suite of right mouse click menus that
make simple things as they should be –
simple. Right click menus are context sensi-
tive, meaning the choices presented in the
menu depend on where you right clicked
the mouse. This makes right click menus
extremely intuitive. Want to change the cursor
type? Right click on a cursor or the cursor
readouts. Want to change the reference levels
of an automatic measurement? Right click
on the measurement. Want to change trigger
parameters? Right click on the trigger read-
outs. Want to change a waveform’s color?
Right click on the waveform handle. Virtually
all objects on the oscilloscope display have
MyScope. MyScope control windows are created using a simple, visual drag and drop process.
right click menus associated with them that
include all the appropriate actions or features
relative to those objects. There are also
right click menus for regions of the display
in addition to just objects. For example, right
clicking in the main graticule brings up a
menu with choices such as Clear Data,
Default Setup, Autoset, Screen Captures,
Save All Waveforms, and Add Screen Text,
providing single click access to many of
your most commonly performed tasks.
The customization and efficiency provided
by MyScope control windows and right click
menus make the TDS5000B Series the world’s
easiest to use midrange oscilloscope, enabling
you to achieve levels of productivity you
wouldn’t have thought possible with your
current oscilloscope.
MyScope. Once created, they are just like other control windows in the instrument and are easily accessed from either the menu or button bars.
The Performance and Feature Set You Expect
Performance
The TDS5000B Series digital phosphor
oscilloscopes (DPO) deliver up to 1 GHz
bandwidth, 5 GS/s real-time sample rate,
16 M record length, and a suite of advanced
triggers, enabling you to capture and char-
acterize even your most demanding signals.
DPOs provide unmatched insight into signal
behavior by displaying, storing and analyzing
complex signals in real-time using three
dimensions of signal information: amplitude,
time and distribution of amplitude over time.
The TDS5000B Series DPO, enabled by
®
Tektronix proprietary DPX
acquisition
2
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
Digital Phosphor Oscilloscopes
TDS5000B Series
Elusive Glitch. Fast waveform capture rate, enabled by Tektronix proprietary DPX acquisition technology, maximizes the probability of capturing elusive glitches and other infrequent events.
technology, delivers greater than 100,000
waveforms per second capture rates.
Some oscilloscope vendors claim high
waveform capture rates for short bursts
of time, but only DPOs, enabled by DPX
technology, can deliver these fast waveform
capture rates on a sustained basis – saving
minutes, hours or even days by quickly
revealing the nature of faults so sophisticated
trigger modes can be applied to isolate them.
Advanced Waveform Analysis
The TDS5000B Series includes a complete
parametric measurement system for signal
characterization. Select from 53 automatic
measurements using a graphical palette
that logically organizes measurements into
Amplitude, Time, Combination, Histogram,
and Communications categories. Gather
further insight into your measurement
results with statistical data such as mean,
min, max, standard deviation, and population.
Waveform cursors make it easy to measure
trace-to-trace timing characteristics, while
cursors that link between YT and XY display
modes make it easy to investigate phase
relationships and Safe Operating Area viola-
tions. Define and apply math expressions
to waveform data for on-screen results in
terms that you can use. Access common
waveform math functions with the touch
of a button. Or, for advanced applications,
create algebraic expressions consisting of
waveforms sources, math functions, meas-
urement values, scalars, and user adjustable
variables with an easy-to-use calculator-
style editor.
Applied measurement extensions can be
installed to enhance TDS5000B capability.
These software applications build on the
precision acquisition performance of the
TDS5000B Series to address the need for
application specific measurements to quick-
ly quantify device and system performance.
Optional applications include power meas-
urement and analysis, jitter and timing
analysis, disk drive measurements, USB
compliance testing, optical storage analysis,
ANSI/ITU telecom pulse compliance, and
Ethernet compliance testing.
OpenChoice Architecture
The TDS5000B Series includes open access
to the MS Windows 2000 operating envi-
ronment. While the instrument remains a
dedicated oscilloscope, the ability to access
the MS Windows desktop creates a powerful
tool. Built-in applications such as WordPad,
Paint and a Web browser allow you to con-
currently maintain lab notes while working
with the instrument. This saves time and
eliminates error-prone steps associated with
transporting images for later report develop-
ment. Other applications such as Microsoft
Word or Excel, MATLAB and LabVIEW can be
installed on the instrument to accomplish
local documentation or signal analysis.
Installation of the oscilloscope on the LAN
enables Web-based information browsing,
e-mail exchange, printing and file sharing.
Using the embedded PCI bus, waveform
data can be moved directly from acquisition
to analysis applications on the Windows
desktop at much faster speeds than
conventional GPIB transfers.
In addition, the OpenChoice architecture
provides a comprehensive software infra-
structure for faster, more versatile operations.
Data transfer programs, such as the Excel
Toolbar, Word Toolbar, and Report Generator
are used to simplify analysis and documen-
tation on the Windows desktop or on external
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
3
Digital Phosphor Oscilloscopes
TDS5000B Series
OpenChoice Platform. Capturing data into Microsoft Excel using the unique Excel Toolbar and then creating a custom report using the Tektronix Report Generator.
PCs. Tektronix’ implementation of industry-
standard protocols, such as TekVISA
interface and ActiveX Control, are included
for using and enhancing Windows applica-
tions for data analysis and documentation.
Or, use the Software Developer’s Kit (SDK) to
help create custom software to automate
multi-step processes in waveform collection
and analysis with Visual BASIC, C, C++,
MATLAB, LabVIEW, La bWindows/CVI and
other common Application Development
Environments (ADE). Integration of the oscil-
loscope with external PCs and non-Windows
hosts is also supported by the TDS5000B
Series software solutions. Plug-and-play
and IVI instrument drivers are included to
enable easy communication with the oscil-
loscope using GPIB, Serial, and LAN
connections from programs running on the
instrument or an external PC. UNIX applica-
tions, and other LAN resources, can connect
directly over Ethernet using the VXI 11.2
server included on the TDS5000B Series.
Digital Design and Debug. Tektronix Integrated View (iView) fully integrates the performance and measurement accuracy of a Tektronix oscilloscope with the multi-channel and powerful triggering capabilities of a Tektronix logic analyzer in one display, allowing designers to quickly verify and debug their designs.
The unparalleled ease-of-use, coupled
with the TDS5000B’s high performance,
OpenChoice platform, and comprehensive
feature set all in a compact benchtop pack-
age, provides exceptional value.
Applications
The TDS5000B Series’ high performance
features make it ideal for a multitude of
applications, such as digital design and debug,
power measurements, communications
mask testing, and video design.
Digital Design and Debug
The interoperability of the TDS5000B Series
oscilloscope with the Tektronix TLA5000
Series logic analyzer made possible by
Tektronix Integrated View (iView
) enables
digital designers to solve signal integrity
challenges and effectively debug and verify
their systems more quickly and easily. The
iView feature fully integrates the industry-
leading performance and measurement
accuracy of a Tektronix oscilloscope with
the multi-channel and powerful triggering
4
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
Digital Phosphor Oscilloscopes
TDS5000B Series
Power Measurements. Channel 1 (yellow, labeled Voltage) shows the turn-off voltage on the FET of a switching power supply, with current on Channel 2 (blue, labeled Current). The Math 1 waveform, M1 (orange, labeled Power), is the instantaneous power resulting from the multiplication of the volt­age and current waveforms (Ch. 1 * Ch. 2). The Math 2 waveform, M2 (purple, labeled Energy), is the result of a calculation of the integral of M1, a math-on-math operation of the TDS5000B Series. An energy meas­urement, located to the right of the display, is a gated measurement made on M1 and includes statistics.
capabilities of a Tektronix logic analyzer.
This integration allows designers to view
time-correlated digital and analog data in
the same display window and isolate the
analog characteristics of the digital signals
that are causing failures in their systems.
The iView Wizard simplifies this integration
of the oscilloscope and logic analyzer by
guiding the user through set up and con-
nection. No user calibration is required.
And, once set up, the iView feature is com-
pletely automated. The result – an integrated
tool set for digital design and troubleshooting.
Communication Mask Testing. Testing an E1 signal against the mask specified by the standard.
Power Measurements
The TDS5000B Series’ powerful and flexible
measurements, math, and math-on-math
capabilities make it an ideal solution for
making power measurements, such as volt-
age, current, instantaneous power, and
energy for power device designers.
Communications Mask Testing
Option SM provides a complete portfolio
of masks for verifying compliance to serial
communications standards. Masks are
provided for electrical standards up to
555 Mb/s and optical standards up to
1.25 Gb/s. Easily tailor mask testing to your
specific requirements using features such
as one-button mask autoset, autofit, user
adjustable mask margin tolerance, hit
counting, failure notifications, and built
in mask editing.
Video Design. Illustration of triggering on an analog HDTV tri-level sync signal and examining horizontal blanking interval.
Video Design
Tektronix exclusive DPX acquisition technology
sets the TDS5000B Series apart from other
digital oscilloscopes, enabling the capture of
up to 100,000 waveforms per seconds for
a live, analog-like display. The TDS5000B
Series also supports a wide variety of video
standards with dedicated triggers including
NTSC, PAL, SECAM and analog HDTV. In
addition, IRE and mV graticules can be
selected for easier measurements and visual
inspection. All of this together makes the
TDS5000B Series an ideal tool for video
design and development.
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
5
Digital Phosphor Oscilloscopes
TDS5000B Series
Characteristics
Vertical System
TDS5032B/ TDS5034B TDS5052B/ TDS5054B/ TDS5104B
TDS5054BE
Input Channels 2/4 2/4/4 4
Analog Bandwidth (–3 dB) 350 MHz 500 MHz 1 GHz 5 mV/div – 1 V/div
Calculated Rise Time 5 mV/div (typical) 1.15 ns 800 ps 300 ps
Hardware Bandwidth Limits 150 MHz or 20 MHz
Input Coupling AC, DC, GND
Input Impedance, 1 M ±1%
Input Impedance, 50 ±1% ±1% ±2.5%
Input Sensitivity, 1 M 1 mV/div to 10 V/div
Input Sensitivity, 50 1 mV/div to 1 V/div
Vertical Resolution 8-bits (>11-bits w/ averaging)
Max Input Voltage, 1 M 150 V CAT I, 400 V peak. Derate at 20 dB/decade to 9 V
Max Input Voltage, 50 5 V
with peaks <±30 V 5 V
RMS
with peaks <±30 V <100 mV/div <1 V
RMS
DC Gain Accuracy 1.5% with offset set to 0 V
Offset Range, 1 M 1 mV/div – 99.5 mV/div ±1 V
100 mV/div – 1 V/div ±10 V
1.01 V/div – 10 V/div ±100 V
Offset Range, 50 1 mV/div – 99.5 mV/div ±1 V 1 mV/div – 99.5 mV/div ±1 V 1 mV/div – 50 mV/div ±0.5 V
100 mV/div –1 V/div ±10 V 100 mV/div –1 V/div ±10 V 50.5 mV/div – 99.5 mV/div ±0.25 V
Channel-to-Channel Isolation for Any 100:1 at 100 MHz and 30:1 at >100 MHz up to the rated bandwidth Two Channels at Equal Vertical Scale
above 200 kHz
RMS
100 mV/div <5 V
100 mV/div – 500 mV/div ±5 V
505 mV/div – 1 V/div ±2.5 V
RMS
RMS
Timebase System
All Models
Timebase Range 200 ps/div to 1000 s/div
Timebase Delay Time Range (s/div x 10) to 1000 s
Channel-to-Channel Deskew Range ±75 ns
Timebase Accuracy 15 ppm
Time Measurement Accuracy (0.06/sample rate + 15 ppm x |Reading|)
Trigger Jitter (RMS) 8 ps
RMS
(typical)
Long Term Sample Rate and Delay Time Accuracy ±15 ppm over any ≥1 ms interval
6
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
RMS
Digital Phosphor Oscilloscopes
TDS5000B Series
Acquisition System
TDS5032B/5052B TDS5034B/5054B/5104B TDS5054BE
Real-time Sample Rates
1 Channel (max) 5 GS/s 5 GS/s 1 GS/s
2 Channels (max) 2.5 GS/s 2.5 GS/s 1 GS/s
3-4 Channels (max) 1.25 GS/s 1 GS/s
Equivalent Time Sample Rate (max) 250 GS/s 250 GS/s 200 GS/s
Maximum Record Length per Channel 8M/4M/— 8M/4M/2M 8M/4M/2M with Standard Memory
With Opt. 3M 16M/8M/— 16M/8M/4M 16M/8M/4M
Maximum Duration at Highest Real-time Resolution (1 ch)
TDS5054BE All Other Models
Time Resolution (single shot) 1 ns (1 GS/s) 200 ps (5 GS/s)
Max Duration with Standard Memory 8 ms 1.6 ms
Max Duration with Opt. 3M 16 ms 3.2 ms
Acquisition Modes
All Models
FastAcq Acquisition FastAcq optimizes the instrument for analysis of dynamic signals and capture
of infrequent events. Maximum FastAcq waveform capture rate
is 100,000 wfms/s
Sample Acquire sampled values
Peak Detect Captures narrow glitches (<1 ns) at all real-time sampling rates
Averaging From 2 to 10,000 waveforms included in average
Envelope From 2 to 2 x 109waveforms included in min-max envelope
Hi-Res Real-time boxcar averaging reduces random noise and increases resolution
Waveform Database Accumulates a waveform database that provides a three dimensional array
of amplitude, time, and counts
FastFrame™Acquisition Acquisition memory divided into segments; maximum trigger
rate >225,000 waveforms per second
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
7
Digital Phosphor Oscilloscopes
TDS5000B Series
Trigger System
All Models
Sensitivity
Internal DC Coupled 0.35 div DC to 50 MHz increasing to 1 div at rated bandwidth
External (auxiliary input) 400 mV from DC to 50 MHz increasing to 750 mV at 100 MHz
Main Trigger Modes Auto, Normal, and Single
Trigger Sequences Main, Delayed by time, Delayed by events. All sequences can include
separate horizontal delay after the trigger event to position
Trigger Level Range
Any Channel ±10 divisions from center of screen
External (auxiliary in) ±8 V
Line Fixed at 0 V
Trigger Coupling DC, AC (attenuate <60 Hz), HF reject (attenuate >30 kHz)
LF reject (attenuates <80 kHz) Noise reject (reduce sensitivity)
Trigger Holdoff Range 1.5 µs to 12 s maximum
the acquisition window in time
Trigger Modes
Edge – Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, AC, noise reject, HF reject, and LF reject.
Video – Trigger on NTSC, PAL, SECAM, analog HDTV, and non-standard video formats.
Glitch – Trigger on or reject glitches of positive, negative or either polarity. Minimum glitch width is 1.0 ns with 200 ps resolution.
Width – Trigger on width of positive or negative pulse either within or out of selectable time limits ranging from 1 ns to 1 s with 200 ps resolution.
Runt – Trigger on a pulse that crosses one thresh­old but fails to cross a second threshold before crossing the first again. Event can be time or logic qualified (logic on 4 channel models only).
Window – Trigger on an event that enters or exits a window defined by two user-adjustable thresh­olds. Event can be time or logic qualified (logic on 4 channel models only).
Timeout – Trigger on an event which remains high, low or either, for a specified time period, selectable from 1 ns to 1 s with 200 ps resolution.
Transition – Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either.
Setup/Hold – Trigger on violations of both setup time and hold time between clock and data present on any two input channels.
Pattern – Trigger when pattern goes false or stays true for specified period of time. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as High, Low or Don’t Care.
State – Any logical pattern of channels (1, 2, 3) clocked by edge on channel 4 (channel 2 on TDS5032B/5052B). Trigger on rising or falling clock edge.
Comm (requires Opt. SM) – Support for AMI, HDB3, B3ZS, B6ZS, B8ZS, CMI, NRZ and MLT3 encoded communication signals. Select among isolated positive or negative one, zero pulse form or eye patterns as applicable to standard.
Trigger Delay by Time – 16 ns to 250 seconds.
Trigger Delay by Events – 1 to
10,000,000 Events.
Waveform Measurements
Automatic Measurements – 53 of which 8 can be displayed on screen at any one time.
ted:
Amplitude Rela
Amplitude, High, Low, Maximum, Minimum, Peak to Peak, Mean, Cycle Mean, RMS, Cycle RMS, Positive Overshoot, Negative Overshoot.
ime Related: Rise Time, Fall Time, Positive Width,
T Negative Width, Positive Duty Cycle, Negative Duty Cycle, Period, Frequency, Delay.
tion: Area, Cycle Area, Phase, Burst Width.
Combina
ram-related: Waveform count, Hits in box,
Histog Peak hits, Median, Maximum, Minimum, Peak to Peak, Mean (µ), Standard Deviation (σ), µ±1σ,µ± 2σ,µ±3σ.
Communica
tions Related: Extinction Ratio (abs, %, dB), Eye Height, Eye Width, Eye Top, Eye Base, Crossing %, Jitter (Pk-Pk, RMS, 6σ), Noise (Pk-Pk, RMS), Signal/Noise Ratio, Cycle Distortion, Q-Factor.
8
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
Digital Phosphor Oscilloscopes
TDS5000B Series
Measurement Statistics – Mean, Min, Max, Standard Deviation, Population.
Reference Levels – User definable for each of the eight measurements.
Histograms – Vertical or horizontal with linear or log scaling.
Gating – Isolate the specific occurrence within an acquisition to take measurements on.
Cursors – Horizontal Bars, Vertical Bars, Waveform, and Screen.
Waveform Processing/Math
Arithmetic – Add, subtract, multiply, and divide waveforms.
Algebraic Expressions – Define extensive algebraic expressions including waveforms, scalars, user adjustable variables, and results of parametric measurements e.g. (Integral (Ch1-Mean(Ch1))*1.414*VAR1).
Math Functions – Average, Invert, Integrate, Differentiate, Square Root, Exponential, Log 10, Log e, Abs, Ceiling, Floor, Min, Max, Sin, Cos, Tan, ASin, ACos, ATan, Sinh, Cosh, Tanh.
Frequency Domain Functions – Spectral magnitude and phase, real and imaginary spectra.
Vertical Units – Magnitude: Linear, dB, dBm. Phase: degrees, radians, group delay.
Window Functions – Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential.
Limit Testing – Compare live waveforms against a known “golden” reference waveform with user defined vertical and horizontal tolerances.
Display Characteristics
Display Type – 10.4 in. Liquid crystal active-matrix color display.
Display Resolution – 640 horizontal x 480 vertical pixels.
Waveform Styles – Vectors, Dots, Intensified Samples, Variable Persistence, Infinite Persistence.
Display Format – YT, XY, XYZ.
Color Palettes – Individual color palettes for
Record View and FastAcq/WfmDB modes include Normal, Green, Gray, Temperature, Spectral, and User Defined.
Computer System and Peripherals
Operating System – Windows 2000.
CPU – Intel Celeron Processor, 2.0 GHz.
PC System Memory – 512 MB.
Internal Hard Disk Drive – 80 GB capacity.
Front Removable Hard Disk Drive (optional) –
40 GB capacity.
Floppy Disk Drive – Front panel 3.5 in floppy disk drive, 1.44 MB capacity.
CD-RW Drive – Side panel CD-RW drive, 24X read and write speed.
Printer (optional) – Built-in thermal printer.
Mouse – Optical wheel mouse, USB interface.
OpenChoice Features
TekVISA – Application Programmers Interface (API) for Windows developers. Documentation includes descriptions and samples of programming test and measurement applications on the unit in Visual BASIC, C and C++.
TekVISA Control (TVC) – Active controls to make access to TekVISA easy for integration into Microsoft Windows applications.
VXI-11 Server – An Application Programmers Interface (API) for LAN connectivity from non-Windows environments.
Plug-and-Play Drivers – Provides support to run National Instrument’s LabVIEW and LabWindows on an external PC connected to a TDS5000B Series or on the oscilloscope itself.
IVI Drivers – Provides support for new and existing program environments utilizing the IVI instrumenta­tion standard, such as LabVIEW, LabWindows/CVI, MATLAB, Visual BASIC, and C/C++.
Excel and Word Toolbars – Provides direct access to screen images, waveform data, and measure­ments on the oscilloscope from a toolbar in Excel and/or Word.
Report Generator – Enables the ability to design and create customized report templates that extract the oscilloscope’s waveforms, settings, measurements, and other on-screen information with a click of the mouse.
LabVIEW and MATLAB – 30 day evaluation copies plus non-expiring demo programs that perform a variety of LabVIEW and MATLAB display and analysis functions with the oscilloscope.
Software Developer’s Kit (SDK) – A CD is included in the Getting Started With OpenChoice
®
book. This SDK includes a wealth of documenta­tion, programming tools, and examples to assist programmers working with the TDS5000B Series.
Input/Output Ports
Auxiliary Input – Front panel BNC connector. Trigger level range is adjustable from +8 V to –8 V. The maximum input voltage is ±20 V (DC + peak AC) and input resistance is 1.5 kΩ.
Probe Compensator Output – Front panel pins. Amplitude 1 V ± 1% into a ≥10 kΩ load, frequen- cy 1 kHz ±5%.
Analog Signal Output – Rear-panel BNC connec­tor, provides a buffered version of the signal that is attached to the Channel 3 input (4 channel models only). Amplitude: 50 mV/div ±20% into a 1 M load, 25 mV/div ±20% into a 50 Ω load. Bandwidth (typical): 100 MHz into a 50 load.
Auxiliary Output Levels – Rear-panel BNC con­nector, provides a TTL-compatible, negative polarity pulse when the oscilloscope triggers.
External Reference In – Rear-panel BNC connec­tor. 9.8 MHz to 10.2 MHz.
Parallel Port – IEEE 1284, DB-25 connector.
Audio Ports – Miniature phone jacks for stereo
microphone input and stereo line output.
USB Port – Two USB 2.0 ports allows connection or disconnection of USB keyboard and/or mouse while oscilloscope power is on.
Keyboard Port – PS-2 compatible.
Mouse Port – PS-2 compatible.
LAN Port – RJ-45 connector, supports 10Base-T
and 100Base-T.
Serial Port – DB-9 COM1 port.
Video Port – DB-15 female connector; connect a
second monitor to use dual-monitor display mode. Supports basic requirements of PC99 specification and display resolutions up to 1,920 x 1,440.
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
9
Digital Phosphor Oscilloscopes
TDS5000B Series
GPIB Port – IEEE 488.2 standard, can be configured for talk/listen or controller mode.
Oscilloscope VGA Video Port – DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector.
Power Source
Power – 100 to 240 V CAT II, or 115 V
RMS
±10%, 47 to 63 Hz;
RMS
±10%, 360 to 440 Hz
Power Consumption – <220 W.
Physical Characteristics
BENCHTOP CONFIGURATION Dimensions mm in.
Height 361 11.2* Width 447 17.6 Depth 288 11.35
Weight kg lbs.
Net 11.23 24.75 Shipping 25.63 56.5
RACKMOUNT CONFIGURATION Dimensions mm in.
Height 267 10.5 Width 483 19 Depth 231*
Weight kg lbs.
Net 13.49 29.75
COOLING
Cooling Clearance 3 inches (76 mm)
*1Does not include accessory pouch.
2
From rackmounting ear to back of instrument.
*
2
required on left side.
9.1*
Environmental
Temperature
Operating – +5 ºC to +45 ºC.
Nonoperating – –20 ºC to +60 ºC without diskette
in floppy drive.
Humidity
Operating – 20% to 80% relative humidity with a maximum wet bulb temperature of +29 ºC at or below +45 ºC, noncondensing. Upper limit de-rates to 30% relative humidity at +45 ºC.
Nonoperating – Without diskette in floppy disk drive. 5% to 90% relative humidity with a maxi-
1
2
mum wet bulb temperature of +29 ºC at or below +60 ºC, noncondensing. Upper limit derates to 20% relative humidity at +60 ºC.
Altitude
Operating –
10,000 ft. (3,048 m).
Nonoperating –
40,000 ft. (12,190 m).
Random Vibration
Operating – 0.1 G
from 5 to 500 Hz, 10 minutes
RMS
each axis, 3-axes, 30 minutes total.
Nonoperating – 2.0 G
from 5 to 500 Hz,
RMS
10 minutes each axis, 3-axes, 30 minutes total.
Regulatory Certifications
Electromagnetic Compatibility – 89/336/EEC.
Safety – UL61010, CSA-22.2 No. 1010.1,
EN61010-1, IEC61010-1.
Ordering Information
TDS5032B
350 MHz, 5 GS/s, 2 channel digital phosphor oscilloscope.
TDS5034B
350 MHz, 5 GS/s, 4 channel digital phosphor oscilloscope.
TDS5052B
500 MHz, 5 GS/s, 2 channel digital phosphor oscilloscope.
TDS5054B
500 MHz, 5 GS/s, 4 channel digital phosphor oscilloscope.
TDS5054BE
500 MHz, 1 GS/s, 4 channel digital phosphor oscilloscope.
TDS5104B
1 GHz, 5 GS/s, 4 channel digital phosphor oscilloscope.
All Models Include: (1) P5050 500 MHz, 10x passive probe per channel, Accessory Pouch (016-1935-00), Front Cover (200-4651-00), Mouse (119-6936-00), Quick Start User Manual, TDS5000B Series Product Software CD-ROM, TDS5000B Series Operating System Restoration CD-ROM, GPIB Programmer’s Reference, Optional Applications Software CD-ROM, Getting Started
with OpenChoice
Kit CD (020-2513-00), 30-day Evaluation Copies
®
book, and Software Developer’s
of MATLAB (063-3609-00) and LabVIEW (020-2476-02), Performance Verification Procedure PDF file, Calibration Certificate Documenting NIST Traceability, Z540-1 Compliance, and ISO9001 Registration, Power Cord.
Please specify power plug and manual version when ordering.
10
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
Digital Phosphor Oscilloscopes
TDS5000B Series
Recommended Probes
P5050 – 500 MHz, 10x passive probe.
P6243 – 1.0 GHz active probe.
P6245 – 1.5 GHz active probe.
P6246 – 400 MHz differential probe.
P6247 – 1.0 GHz differential probe.
P6248 – 1.7 GHz differential probe.
Recommended Accessories
Service Manual – Order 071-1362-00.
Transit Case – Order 016-1937-00.
Probe Calibration, Compensation, and Deskew Adapter – Order 067-0405-xx.
Power Deskew Fixture – Order 067-1478-00.
Extra Front Panel Removable Hard Drive –
Order 065-0692-00.
Video Display Clamp – Order 013-0278-xx.
Thermal Printer Paper – Order 016-1897-00.
Mini Keyboard – Order 118-9402-00.
USB Test Fixture – Order TDSUSBF.
Ethernet Test Fixture – Order through Crescent
Heart Software (www.c-h-s.com).
Instrument Options (available on all models unless indicated otherwise)
Opt. 18 – Touch-screen interface.
Opt. 3M – Increase record length to 16M samples
max (1ch.).
Opt. 1P – Built-in thermal printer.
*1
Opt. FHD
Front panel removable hard drive
(replaces FDD and internal HDD).
Opt. 1K – Oscilloscope cart.
Opt. 1R – Rackmount kit.
Opt. SM – Communication mask testing.
Opt. PS1 – Power Bundle that includes TCP202
DC Coupled Current Probe, P5205 High Voltage Differential Probe, TDSPWR3 Power Measurement Software, and Power Deskew Fixture.
*2
Opt. CP2
TDSCPM2 - ANSI/ITU telecom
pulse compliance testing software.
Opt. DVD – TDSDVD - Optical storage analysis software.
*3
Opt. ET3
TDSET3 - Ethernet compliance
test software.
*4
Opt. J2
TDSDDM2 - Disk drive measurements
software.
*5
Opt. J3E
TDSJIT3E - Jitter and timing analysis
software essentials.
*5
Opt. JT3
TDSJIT3 - Jitter and timing analysis
software with Rj/Dj and BER.
Opt. PW3 – TDSPWR3 - Power measurements software.
*5
Opt. USB
USB 2.0 Compliance test
software only.
*1No upgrade path for this option, must be ordered at time
of initial purchase.
*2Requires option SM.
3
Not available on TDS5054BE
*
4
Not available on TDS5032B and TDS5034B.
*
5
Not available on TDS5032B and TDS5052B.
*
Power Plug Options
Opt. A0 – North America.
Opt. A1 – Universal Euro.
Opt. A2 – United Kingdom.
Opt. A3 – Australia.
Opt. A4 – 240 V North America.
Opt. A5 – Switzerland.
Opt. A6 – Japan.
Opt. A10 – China.
Opt. A99 – No power cord or AC adapter.
Manual Options
Opt. L0 – English manual.
Opt. L1 – French manual.
Opt. L3 – German manual.
Opt. L5 – Japanese manual.
Opt. L7 – Simple Chinese manual.
Opt. L8 – Traditional Chinese manual.
Opt. L9 – Korean manual.
Opt. L10 – Russian manual.
Service Options
Opt. C3 – Calibration Service 3 Years.
Opt. C5 – Calibration Service 5 Years.
Opt. D1 – Calibration Data Report.
Opt. D3 – Calibration Data Report 3 Years
(with Option C3).
Opt. D5 – Calibration Data Report 5 Years (with Option C5).
Opt. R3 – Repair Service 3 Years (including warranty).
Opt. R5 – Repair Service 5 Years (including warranty).
Instrument Upgrades
Upgrades equivalent to original options can be ordered to extend instrument performance after initial purchase. Users can install upgrades without opening the instrument case or requiring on-site service (except for touch-screen upgrade). To upgrade, order a TDS5BUP with one or more of the following options: 18, 1K, M03, 1P, 1R, SM, CP2, DVD, ET3, J2, J3E, JT3, PW3, USB. Factory installation of selected options is available by ordering option IF on your TDS5BUP upgrade order.
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
11
Digital Phosphor Oscilloscopes
TDS5000B Series
Contact Tektronix:
ASEAN / Australasia / Pakistan (65) 6356 3900
Austria +43 2236 8092 262
Belgium +32 (2) 715 89 70
Brazil & South America 55 (11) 3741-8360
Canada 1 (800) 661-5625
Central Europe & Greece +43 2236 8092 301
Denmark +45 44 850 700
Finland +358 (9) 4783 400
France & North Africa +33 (0) 1 69 86 80 34
Germany +49 (221) 94 77 400
Hong Kong (852) 2585-6688
India (91) 80-22275577
Italy +39 (02) 25086 1
Japan 81 (3) 6714-3010
Mexico, Central America & Caribbean 52 (55) 56666-333
The Netherlands +31 (0) 23 569 5555
Norway +47 22 07 07 00
People’s Republic of China 86 (10) 6235 1230
Poland +48 (0) 22 521 53 40
Republic of Korea 82 (2) 528-5299
Russia, CIS & The Baltics +358 (9) 4783 400
South Africa +27 11 254 8360
Spain +34 (91) 372 6055
Sweden +46 8 477 6503/4
Taiwan 886 (2) 2722-9622
United Kingdom & Eire +44 (0) 1344 392400
USA 1 (800) 426-2200
USA (Export Sales) 1 (503) 627-1916
For other areas contact Tektronix, Inc. at: 1 (503) 627-7111
Last Update March 01, 2004
12
Digital Phosphor Oscilloscopes
www.tektronix.com/tds5000b
Our most up-to-date product information is available at:
www.tektronix.com
Product(s) are manufactured
in ISO registered facilities.
Copyright © 2004, Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or regis­tered trademarks of their respective companies.
04/04 HB/BT 55W-14869-9