Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the
Rights in Technica l Data a nd Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the
Commercial Computer Software -- Restricted Rights clause at FAR 52.227-19, as applicable.
Tektronix product s are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX, TEK, TekConnect, and
TeKProbe are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc .
14200 SW Karl Braun Drive or P.O. Box 500
Beaverton, OR 97077 USA
For product information, sales, service, and te chnical support:
HIn North America, call 1-800-833-9200.
HWorldwide, visit www.tektronix.com to find contacts in your area.
Warranty 2
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1)
year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its
option, either will repair the defective product without cha rge for parts and labor, or will provide a replacement in
exchange for the defective product. Parts, modules and replaceme nt produc ts used by Tektronix for warranty work
may be new or reconditioned to like new performance. All replaced parts, modules and products become the
property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration
of the warranty period and make suitable arrangements for the performance of service. Customer shall be
responsible for packaging and shipping the defective product to the service center designated by Tektronix, with
shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a
location within the country in which the Tektronix service center is located. Customer shall be responsible for
paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shal l not be obliga ted to furnish service under this warranty a) to repair damage
resulting from attempts by personnel ot her than Tektronix representatives to install, repair or service the product;
b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been
modified or integrated with other products when the effect of such modificat ion or integration increases t he time
or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY
OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND
EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY.
TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL,
OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS
ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table of Contents
General Safety Summaryiii...................................
Review the following safety precautions to avoid injury and prevent damage to
this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read
the General Safety Summary in other system manuals for warnings and cautions
related to operating the system.
ToAvoidFireor
Personal Injury
Connect and Disconnect Properly. Do not connect or disconnect probes or test
leads while they are connected to a voltage source.
Connect the probe output to the measurement instrument before connecting the
probe to the circuit under test. Disconnect the probe input and the probe ground
from the circuit under test before disconnecting the probe from the measurement
instrument.
Ground the Product. This product is grounded through the grounding conductor
of the power cord. To avoid electric shock, the grounding conductor must be
connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings
and markings on the product. Consult the product manual for further ratings
information before making connections to the product.
The common terminal is at ground potential. Do not connect the common
terminal to elevated voltages.
Connect the ground lead of the probe to earth ground only.
Do not apply a potential to any terminal, including the common terminal, that
exceeds the maximum rating of that terminal.
RTPA2A Instruction Manual
Power Disconnect. The power cord disconnects the product from the power
source. Do not block the power cord; it must remain accessible to the user at all
times.
Do Not Operate Without Covers. Do not operate this product with covers or panels
removed.
Avoid Exposed Circuitry. Do not touch exposed connections and components
when power is present.
Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
iii
General Safety Summary
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
Use Proper AC Adapter. Use only the AC adapter specified for this product.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Symbols and Terms
Terms in this Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the
marking.
WARNING indicates an injury hazard not immediately accessible as you read the
marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. The following symbols may appear on the product:
CAUTION
Refer to Manual
iv
RTPA2A Instruction Manual
Environmental Considerations
This section provides information about the environmental impact of the
product.
Product End-of-Life
Handling
Restriction of Hazardous
Substances
Observe the following guidelines when recycling an instrument or component:
Equipment Recycling. Production of this equipment required the extraction and
use of natural resources. The equipment may contain substances that could be
harmful to the environment or human health if improperly handled at the
product’s end of life. In order to avoid release of such substances into the
environment and to reduce the use of natural resources, we encourage you to
recycle this product in an appropriate system that will ensure that most of the
materials are reused or recycled appropriately.
The symbol shown to the left indicates that this product
complies w ith the European Union’s requirements
according to Directive 2002/96/EC on waste electrical and
electronic equipment (WEEE). For information about
recycling options, check the Support/Service section of the
Tektronix Web site (www.tektronix.com).
This product has been classified as Monitoring and Control equipment, and is
outside the scope of the 2002/95/EC RoHS Directive. This product is known to
contain lead, cadmium, mercury, and hexavalent chromium.
RTPA2A Instruction Manual
v
Environmental Considerations
vi
RTPA2A Instruction Manual
Getting Started
The TekConnect probe adapter allows you to connect a TekConnect probe to a
Real-Time Spectrum Analyzer. The TekConnect probe adapter is comprised of an
enclosure that houses two probe inputs. The probe adapter connects to a
Real-Time Spectrum Analyzer through a USB cable and a coaxial cable.
Figure 1: The TekConnect probe adapter
Cable Connections
Power
USB Cable
The power for the probe adapter and probe is supplied through the DC power
supply cable.
The USB cable provides a data and communications path from the probe adapter
to the Real-Time Spectrum Analyzer. Probe characteristic data transfers through
this cable.
If your product is running Windows 98 application software, you need to
upgrade to Windows XP to use the TekConnect probe adapter. To upgrade your
product, contact the Tektronix support center (for contact information, see the
contact page at the front of this manual).
If your product is a RSA2200A, RSA3300A, RSA3408A, or WCA200A Series
instrument, it requires Main System software shipped after August 2005 to be
compatible with the TekConnect probe adapter. Contact Tektronix technical
support if you need to verify that your Main System software supports the
RTPA2A TekConnect probe adapter.
For questions about an instrument not listed here, contact the Tektronix support
center.
T ekConnect Probe Compatibility
The TekConnect probe adapter supports only TekConnect probes. Refer to
Table 1 for a list of compatible probes.
Table 1: Compatible probes
ProbeAttenuationDescription
P722510xActive Probe
P72405xActive Probe
P72605x, 25xActive Probe
P73305xDifferential Probe
P73135x, 25xDifferential Probe
P73506.25xDifferential Probe
P7350SMA6.25xDifferential Probe
P73805x, 25xDifferential Probe
P7380SMA2.5x 12.5xDifferential Probe
There is no support for TekProbe Level 2 legacy probes that use the
TCA-1MEG, TCA-BNC, and TCA75 adapters.
2
RTPA2A Instruction Manual
Standard Accessories
Table 2: Standard accessories
Getting Started
Table 2 lists the standard accessories. Order extra standard accessories as needed.
AccessoryDescription
50 Ω SMA-to-N Cable. Use the 50 Ω SMA-to-N Cable to connect the TekConnect probe
adapter to the Real-Time Spectrum Analyzer. The SMA cable passes the analog signal output
from the probe adapter channel to the spect rum analyzer
BNC-to-N adapter. Use the BNC-to-N adapter to connect the TekConnect probe adapter to the
Real-Time Spectrum Analyzer RF input.
USB Cable. Provides a data and communications path from a TekConnect probe adapter to the
Real-Time Spectrum Analyzer
Power Cord. Provides AC power to the power supply. Option A0 comes standard with the
TekConnect probe adapter. See page 5 for power cord options.
1
.
.
RTPA2A Instruction Manual
3
Getting Started
Table 2: Standard accessories (Cont.)
AccessoryDescription
Power Supply and cable. Provides DC power to the TekConnect probe adapter.
Statement of compliance. A certificate verifying that the product is assem bled and verified
Statement of
compliance
using est ablished procedures and work instructions. When applicable, test equipment is
traceable t o known standards.
Included with product at initial shipment. This accessory cannot be ordered.
Instruction Manual. Provides instruction and information about the TekConnect probe adapter.
Quick Reference Card. Provides RF, I, and Q setups f or the TekConnect probe adapter and the
Real-Time Spectrum Analyzer
1
See page 32 for Tektronix part numbers.
1
.
4
RTPA2A Instruction Manual
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.