Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 50 0
Beaverto
USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200.
Worldwide, visit www.tek.com to find contacts in your area.
Service safety summary
The Service safety summary section contains additional information required to
safely perform service on the product. Only qualified personnel should perform
service proc
service procedures.
To avoid electric shock. Do not touch exposed connections.
Do not service alone. Do not perform internal service or adjustments of this
product un
present.
Disconnect power. To avoid electric shock, switch off the product power and
disconnect the power cord from the mains power before removing any covers or
panels, or opening the case for servicing.
Use care when servicing with power on. Dangerous voltages or currents may exist
in this product. Disconnect power, remove battery (if applicable), and disconnect
test leads before removing protective panels, soldering, or replacing components.
Verify safety after repair. Always recheck ground continuity and mains dielectric
ngth after performing a repair.
stre
edures. Read this Service safety summary before performing any
less another person capable of rendering first aid and resuscitation is
SPG8000A, SPG8000, and SPG700 Option SDI Bracket Installation Instructions1
Installation description
Installation description
This document contains installation instructions for adding a retaining bracket to
secure the Option SDI output boards in the following instruments:
SPG8000A Master Sync / Clock Reference Generator
SPG8000 Master Sync / Clock Reference Generator
SPG700 Multiformat Reference Sync Generator
Parts list
The following table lists the parts that are needed for installation.
Index No.QuantityPart NumberDescription
12220-A095-XX
21407-6120-XX
Figure 1: Installation parts diagram
NUT, PLA
TOOHED WASHER
BRACKE
IN, HEX: M3, STL, NI PL, W/EXT
T PCB, HOLD DOWN
2SPG8000A, SPG8000, and SPG700 Option SDI Bracket Installation Instructions
Installation instructions
These instructions are for personnel who are familiar with servicing the product.
Contact your nearest Tektronix, Inc., Service Center or Tektronix Factory Service
for installa
WAR NI NG . Dangerous voltages may be present. To prevent electrical shock,
disconnect the power cord from the unit before starting the installation procedure.
Failure to do so could cause serious injury or death.
CAUTION. Many components within the instrument are susceptible to static-static
discharge damage. To prevent static discharge damage, service the product
only in a static-free environment. Observe standard handling precautions for
static-sensitive devices while installing this kit. Always wear a grounded wrist
strap, g
tion assistance.
rounded foot strap, and static resistant apparel while installing this kit.
Installation instructions
Recommended tool list
Table 1: Recommended tool list
NameDescription
ts Phillips-driver bits.
Screwdriver handle
#1 and #2 Phillips tipsPhillips-driver bits for #1 and #2 size screw
Nut driver, 7/32” (5.5 mm)
Accep
heads.
Wrench or deep nut driver, to remove
nuts from bracket securing the SDI output
ules.
mod
SPG8000A, SPG8000, and SPG700 Option SDI Bracket Installation Instructions3
Installation instructions
Option SDI bra
cket installation
Complete the following steps to secure the Option SDI output boards in the
instrument:
NOTE. The st
from the SPG8000A are used to illustrate each step.
1. Set the ins
rear is facing you.
2. Remove th
a. Use a screwdriver with a #1 Phillips tip or #2 Phillips tip (depending
on your u
instrument.
b. Lift th
eps apply to the SPG8000A, SPG8000, and SPG700, but images
trument so that the bottom is down on the work surface and the
e top cover as follows:
nit) to remove the 22 screws securing the top cover to the
e top cover off the chassis.
4SPG8000A, SPG8000, and SPG700 Option SDI Bracket Installation Instructions
Figure 2: Removing the top cover
Installation instructions
3. Push down on the
with the connectors.
SDI output cards to make sure they are fully engaged
Figure 3: Fully engage SDI output cards
4. Place the bracket on to the two extended screws on the chassis fan.
Figure 4: Place the bracket on the fan screws
SPG8000A, SPG8000, and SPG700 Option SDI Bracket Installation Instructions5
Installation instructions
5. Install the two
nuts securing the bracket to the chassis fan screws using a
7/32 inch (5.5 mm) nut driver. Torque the nuts to 5 in/lbs.
Figure 5: Install the nuts on the bracket
6. Reinstall the top cover. Torque the cover screws to 5.5 in/lbs.