Tektronix DPO3012, DPO3014, DPO3032, DPO3034, DPO3052 Primary User

...
x
MSO3000 and DPO3000 Series Digital Phosphor Oscilloscopes
ZZZ
User Manual
*P071265602*
071-2656-02
xx
MSO3000 and DPO3000 Series Digital Phosphor Oscilloscopes
ZZZ
User Manual
www.tektronix.com
071-2656-02
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by na
tional copyright laws and international treaty provisions.
Tektronix pro previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
e*Scope, OpenChoice, TekVPI, and Wave Inspector are registered trademarks of Tektronix, Inc.
MagniVu, iView, and TekSecure are trademarks of Tektronix, Inc.
PictBridge is a registered trademark of the Standard of Camera & Imaging Products Association CIPA DC-001-2003 Digital Photo Solutions for Imaging Devices.
Contactin
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to nd contacts in your area.
ducts are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all
g Tektronix
MSO3000 and DPO 3000 Series Oscilloscopes
Warranty
Tektronix warrants that the product will be free from defects in materials and workmanship for a period of three (3) years from the date of original pu option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty. Parts, modules and replacement products used by Tektronix for warranty work may be ne
rchase from an authorized Tektronix distributor. If the product proves defective during this warranty period, Tektronix, at its
w or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to ob period and make suitable arrangements for the performance of s ervice. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. T the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tekt other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to serv increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS IS THE SOLE AND E XCLU S IVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. T EKT RONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPE DAMAGES.
[W16 – 15AUG04]
tain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty
ektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which
ronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel
ice a product that has been modied or integrated with other products when the effect of such modication or integration
FOR A PARTICULAR PURPOSE. TEKTRONIX' RESPONSI BILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS
CTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE N OTICE OF THE PO SSIBILITY OF SUCH
P6139B Probe
Warranty
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modul
ny such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective
es and products become the property of Tektronix.
In order to ob and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to C be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modied or integrated with other products when the effect of such modication or integration increase
THIS WARR EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SO AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE PO SSIBILITY OF SUCH DAMAGES
[W2 – 15
tain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period
ustomer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall
Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or
s the time or difculty of s ervicing the product.
ANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES,
LE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FO R BREACH OF THIS WARRANTY. TEKTRONIX
.
AUG04]
P6316 Probe
Warranty
Tektronix warrants that the product will be free from defects in materials and workmanship for a period of one (1) year from the date of original purc option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty. Parts, modules and replacement products used by Tektronix for warranty work may be ne
hase from an authorized Tektronix distributor. If the product proves defective during this warranty period, Tektronix, at its
w or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to ob period and make suitable arrangements for the performance of s ervice. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. T the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tekt other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to serv increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS IS THE SOLE AND E XCLU S IVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. T EKT RONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPE DAMAGES.
[W15 – 15AUG04]
tain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty
ektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which
ronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel
ice a product that has been modied or integrated with other products when the effect of such modication or integration
FOR A PARTICULAR PURPOSE. TEKTRONIX' RESPONSI BILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS
CTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE N OTICE OF THE PO SSIBILITY OF SUCH
Table of Contents
General Safety Summary ... ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . ... v
Compliance Information.............................................................................................................. vii
EMC Compliance................................................................................................................ vii
Safety Compliance............................................................................................................... ix
Environmental Considerations................................................................................................... xi
Preface................................................................................................................................ xii
Key Features ................................................................................................................... xiii
Conventions Used in This Manual.. ... .. . .. ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . .. ... .. . .. .. . .. ... .. . . xiv
Installation.............................................................................................................................. 1
Before Installation................................................................................................................ 1
Operating Considerations........................................................................................................ 5
Connecting Probes. .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . . 8
Securing the Oscilloscope ....................................................................................................... 9
Powering On the Oscilloscope .................................................................................................. 9
Powering Off the Oscilloscope.................................................................................................. 10
Functional Check. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. . .. .. . .. . . . .. . .. .. . .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. 10
Compensating a Passive Voltage Probe . . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. 12
Application Module Free Trial... .. . .. . . . .. . .. .. . .. .. . .. . . . .. . .. .. . .. .. . .. . . . .. . .. .. . .. .. . .. . . . .. . .. .. . .. .. . .. . . . .. ... .. . .. .. . .. . 12
Installing an Application Module. . .. . .. .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. .. . .. . . . .. . .. .. . .. .. . .. . . . . 13
Upgrading Bandwidth . .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. . 13
Changing the User Interface Language . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. 15
Changing the Date and Time .. . .. . .. .. . .. . .. .. . .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . .. .. . .. . .. .. 16
Changing the Font Appearance ... . .. .. . .. . .. .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . . . .. . .. .. 17
Signal Path Compensation . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . 19
Upgrading Firmware ............................................................................................................ 20
Connecting Your Oscilloscope to a Computer ... .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. ... .. 24
Connecting a USB Keyboard to Your Oscilloscope. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . 28
Get Acquainted with the Instrument ................................................................................................. 29
Front-Panel Menus and Controls. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. 29
Front-Panel Connectors ... .. . .. ... .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. ... .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. 41
Panel Connector. .. . .. . .. .. . .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . . . .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . . . . 42
Side
Rear-Panel Connectors. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. ... .. . .. .. . .. . . . .. . .. .. . .. 42
Acquire the Signal ... .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . ..... 44
Setting Up Analog Channels.. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. . .. .. . .. . . . .. . .. .. . .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. 44
Using the Default Setup......................................................................................................... 47
Using Autoset ................................................................................................................... 48
Acquisition Concepts............................................................................................................ 49
How the Analog Acquisition Modes Work.. .. . .. . . . .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. 50
Changing the Acquisition Mode, Record Length, and Delay Time. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. . .. .. . 51
Using Roll Mode................................................................................................................. 53
Setting Up a Serial or Parallel Bus ............................................................................................. 54
Setting Up Digital Channels . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . .. . .. 66
Table of Content
s
MSO3000 and DPO3000 Series Oscilloscopes User Manual i
Table of Content
Trigger Setup . .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . ....... 70
Display Waveform Data .............................................................................................................. 84
Analyze Waveform Data. . .. . .. .. . .. .. . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . . 100
Save and Recall Information....................................................................................................... 124
Using Application Modules .. .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .139
Application Examples............................................................................................................... 140
s
When and Why to Turn On MagniVu. .. . .. . .. . . . .. . .. . .. .. . .. . .. ... .. . .. . .. .. . .. . .. ... .. . .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. . .. .. . 68
Using MagniVu . . .. .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. .. . .. . .. .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. .. . .. . . . .. . .. .. . .. ... .. . .. .. . . 68
Triggering Concepts............................................................................................................. 70
Choosing a Trigger Type . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . 73
Selecting Triggers. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. ... .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. ... .. . .. .. . .. .. . .. . ..74
Triggering on Buses............................................................................................................. 76
Checking Trigger Settings .. .. . .. ... .. . .. .. . .. . . . .. . .. .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. .. . .. . .. .. . .. .. . .. ... .. . .. .. . .. . . . .. . . 81
Using Sequence Trigger, A (Main) and B (Delayed).. . .. . . . .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. 81
Starting and Stopping an Acquisition. ... .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . 83
Adding and Removing a Waveform ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... .. . .. 84
Setting the Display Style and Persistence ..................................................................................... 84
Setting Waveform Intensity ..................................................................................................... 88
Scaling and Positioning a Waveform ........................................................................................... 89
Setting Input Parameters . . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . . 90
Positioning and Labeling Bus Signals. . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. 94
Positioning, Scaling, and Grouping Digital C hannels .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . 95
Viewing Digital Channels . . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. ... .. . .. .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. 97
Annotating the Screen .. . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . 97
Viewing the Trigger Frequency ... . .. . .. .. . .. . .. .. . .. . .. ... .. . .. . . . .. . .. .. . .. . .. ... .. . .. . . . .. . .. ... .. . .. . .. .. . .. . .. .. . .. . .. .. . .. 98
Taking Automatic Measurements............................................................................................. 100
Selecting Automatic Measurements.......................................................................................... 101
Customizing an Automatic Measurement.................................................................................... 104
Taking Manual Measurements with Cursors ... . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . 108
Using Math Waveforms ....................................................................................................... 112
Using FFT ..................................................................................................................... 113
Using Advanced Math......................................................................................................... 115
Using Reference Waveforms ................................................................................................. 116
Using Wave Inspector to Manage Long Record Length Waveforms.. . .. .. . .. . .. .. . .. . . . .. . .. ... .. . .. ... .. . .. .. . .. . .. .. . .. . 118
Analyzing Power . ... .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . . . .. . .. ... .. . .. ... .. . .. . . . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. 123
Saving a Screen Image ....................................................................................................... 126
Saving andRecalling Waveform Data........................................................................................ 127
Saving andRecalling Setups................................................................................................. 129
Saving with One Button Push ................................................................................................ 130
Managing Drive, Directories, and Files.. . .. .. . .. . .. .. . .. ... .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. ... .. . .. .. . .. . .. 131
Printing a Hard Copy.......................................................................................................... 132
Erasing Oscilloscope Memory................................................................................................ 137
Taking Simple Measurements ................................................................................................ 140
Analyzing Signal Detail . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. .. . 147
Triggering on a Video Signal. .. . .. .. . .. .. . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. . .. .. . .. ... 151
ii MSO3000 and DPO3000 Series Oscilloscopes User Manual
Table of Content
Capturing a Single-Shot Signal.. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . .. .. . .. . .. .. . .. ... .. . .. .. . .. ... .. . .. .. . . 154
Correlating Da
ta with a TLA Logic Analyzer . .. .. . .. . .. .. . .. . .. .. . .. ... .. . .. ... .. . .. .. . .. . .. .. . .. . .. .. . .. . . . .. . .. .. . .. . .. .. . . 157
Tracking Down Bus Anomalies ... .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . . 159
Troubleshooting an RS-232 Bus ... . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . . . .. . .. ... .. . .. ... .. . .. . . . .. . .. .. . .. . .. .. . .. . .. .. 161
Troubleshoot
ing Circuits Using Parallel Buses .............................................................................. 163
Appendix: Warranted Specications............................................................................................... 165
Index
s
MSO3000 and DPO3000 Series Oscilloscopes User Manual iii
Table of Content
s
iv MSO3000 and DPO3000 Series Oscilloscopes User Manual
General Safety S
ummary
General Safet
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specied.
Only qualied personnel should perform service procedures.
To Avoid Fire or Personal Injury
Use proper power cord. Use only the power cord specied for this product and certied for the country of use.
Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected
to a voltage source.
Connect and disconnect properly. De-energize the circuit under test before connecting or disconnecting the current
probe.
Ground th
shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult the
product
Connect
e product.
manual for further ratings information before making connections to the product.
the probe reference lead to earth ground only.
y Summary
This product is grounded through the grounding conductor of the power cord. To avoid electric
Do not ap
Power d
must remain accessible to the user at all times.
ply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
isconnect.
The power cord disconnects the product from the power source. Do not block the power cord; it
Do not operate without covers. Do not operate this product with covers or panels removed.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by
qualied service personnel.
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
Do not operate in wet/damp conditions.
Do not operate in an explosive a tmosphere.
Keep product surfaces clean and dry.
Provide proper ventilation.
per ventilation.
pro
Refer to the manual's installation instructions for details on installing the product s o it has
MSO3000 and DPO3000 Series Oscilloscopes User Manual v
General Safety S
Terms in This Manual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could r esult in damage to this product or other property.
Symbols and Terms on the Product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
ummary
vi MSO3000 and DPO3000 Series Oscilloscopes User Manual
Compliance Info
rmation
Compliance In
This section lists the EMC (electromagnetic compliance), safety, and environmental standards with which the instrument complies.
EMC Compliance
EC Declaration of Conformity – EMC
Meets intent of Directive 2004/108/EC for Electromagnetic Compatibility. Compliance was demonstrated to the following specications as listed in the Ofcial Journal of the European Communities:
EN 61326-1:2006, EN 61326-2-1:2006. EMC requirements for electrical equipment for measurement, control, and
laboratory use.
CISPR 11:2003. Radiated and con
IEC 61000-4-2:2001. Electrostatic discharge immunity
IEC 61000-4-3:2002. RF electromagnetic eld immunity
IEC 61000-4-4:2004. Electrical fast transient/burst immunity
IEC 61000-4-5:2001. Power line surge immunity
IEC 61000-4-6:2003. Conducted RF immunity
IEC 61000-4-11:2004. Voltage dips and interruptions immunity
1234
formation
ducted emissions, Group 1, Class A
5
6
7
EN 61000-3-2:2006. AC power line harmonic emissions
EN 61000-3-3:1995. Voltage changes, uctuations, and icker
European Contact.
Tektronix UK, Ltd. Western Peninsula Western Road Bracknell, RG12 1RF United Kingdom
1
This product is i ntended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2
Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object.
3
To ensure compliance with the EMC standards listed here, high quality shielded interface cables should be used.
4
Instrument rebooting may be experienced where the EUT takes longer than 10 seconds to recover from the IEC 61000-4-11 transient immunity test.
5
The increase in trace noise while subjected to the test eld (3 V/m over the frequency range 80 MHz to 1 GHz, 1.4 GHz to 2.0 GHz, and 1 V/m from 2.0 GHz to 2.7 GHz, with 80% amplitude modulation at 1 kHz) is not to exceed 1 major division of induced noise in the channel at 20 mV/div, sample mode , 100 us/div. (IEC 61000-4-3).
6
The increase in trace noise while subjected to the injected test signal (3 V rms over the frequency range of 150 kHz to 80 MHz, with 80% amplitude modulation at 1 kHz) is not to exceed 1 major division of induced noise in the c hannel at 20 mV/div, sample mode, 100 us/div (IEC 61000-4-6).
7
Performance Criterion C applied at the 70%/25 cycle Voltage-Dip and the 0%/250 cycle Voltage-Interruption test levels (IEC 61000-4-11).
MSO3000 and DPO3000 Series Oscilloscopes User Manual vii
Compliance Info
Australia / New Zealand Declaration of Conformity – E MC
Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA:
CISPR 11:2003. Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1:2006 and EN 61326-2-1:2006.
rmation
viii MSO3000 and DPO3000 Series Oscilloscopes User Manual
Safety Compliance
EC Declaration of Conformity – Low Voltage
Compliance was demonstrated to the following specication as listed in the Ofcial Journal of the European Communities:
Low Voltage Directive 2006/95/EC.
EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use.
Compliance Info
rmation
U.S. Nation
UL 61010-1:2004, 2ndEdition. Standard for electrical measuring and test equipment.
ally Recognized Testing Laboratory Listing
Canadian Certication
CAN/CSA­laboratory use. Part 1.
C22.2 No. 61010-1:2004. Safety requirements for electrical equipment for measurement, control, and
Additional Compliances
IEC 61010-1: 2001. Safety requirements for electrical equipment for measurement, control, and laboratory use.
Equipment Type
Test and measuring equipment.
y Class
Safet
Class 1 – grounded product.
Pollution Degree Description
asure of the contaminants that could occur in the environ ment around and within a p roduct. Typically the internal
Ame environment inside a product is considered to be the same as the external. Products should be used only in the environment for which they are rated.
Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally
capsulated, hermetically sealed, or located in clean rooms.
en
llution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is
Po caused by condensation must be expected. This location is a typical ofce/home environment. Temporary condensation occurs only when the product is out of service.
Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation.
hese are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct
T sunshine, rain, or direct wind.
Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical outdoor locations.
MSO3000 and DPO3000 Series Oscilloscopes User Manual ix
Compliance Info
Pollution Degree
Pollution Degree 2 (as dened in IEC 61010-1). Note: Rated for indoor use only.
Installation (Overvoltage) Category Descriptions
Terminals on this product may have different installation (overvoltage) category designations. The installation categories are:
Measurement Category IV. For measurements performed at the source of low-voltage installation.
Measurement Category III. For measurements performed in the building installation.
Measurement Category II. For measurements performed on circuits directly connected to the low-voltage installation.
Measurement Category I. For measurements performed on circuits not directly connected to MAINS.
rmation
Overvolta
Overvoltage Category II (as dened in IEC 61010-1).
ge Category
x MSO3000 and DPO3000 Series Oscilloscopes User Manual
Environmental Considerations
This section provides information about the environmental impact of the product.
Product End-of-Life Handling
Observe the following guidelines when recycling an instrument or component:
Equipment Recycling. Production of this equipment required the extraction and use of natural resources. The
equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product’s end of life. In order to avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Compliance Info
rmation
Mercury N
to environmental considerations. Please contact your local authorities or, within the United States, refer to the E-cyc ling Central Web page (www.eiae.org) for disposal or recycling information.
Restric
This product has been classied as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive.
otication.
tion of Hazardous Substances
This product uses an LCD backlight lamp that contains mercury. Disposal may be regulated due
MSO3000 and DPO3000 Series Oscilloscopes User Manual xi
Preface
Preface
This manual describes the installation and operation of the following oscilloscopes:
MSO3054 MSO3034 MSO3032 MSO3014 MSO3012 DPO3054 DPO3052 DPO3034 DPO3032 DPO3014 DPO3012
xii MSO3000 and DPO3000 Series Oscilloscopes User Manual
Key Features
MSO3000 and DPO3000 Series instruments can help you verify, debug, and characterize electronic designs. Key features include:
500 MHz, 300 MHz, and 100 MHz bandwidths – models with 100 MHz or 300 MHz bandwidths can be upgraded up to 500 MHz
2 channel and 4 channel models
Sample rates up to 2.5 GS/s on all analog channels
5 M points record length on all channels
50,000 waveforms/second display rate
Preface
Bus triggering and analysis (with the appropriate application m odule and model oscilloscope) for I2C, SPI, MIL-STD-1553, CAN, LIN, FlexRay, RS-232, RS-422, RS-485, UART, I
Power analysis application module (optional)
Wave Inspector controls for managing long record lengths, with zoom and pan, play and pause, search and mark
229 mm (9 inch), with 800 x 480 resolution, WVGA color display
Small and lightweight, at 127 mm (5 inches) deep and 4.1 kg (9 pounds)
USB available for quick and easy storage
Direct printing to any PictBridge-compatible printer
Built-in Ethernet port
USB 2.0 device port for direct PC control of the oscilloscope using USBTMC protocol
OpenChoice documentation and analysis software
NI LabVIEW SignalExpress™ Tektronix E dition productivity and analysis software
Remote viewing and control with e*Scope
Remote control with VISA connectivity
TekVPI Versatile Probe Interface supports active, differential, and current probes for automatic scaling and units
MSO3000 Series Mixed Signal Oscilloscopes also offer:
2
S, Left Justied (LJ), Right Justied (RJ), TDM
MagniVu 121.2 ps resolution
Parallel bus triggering and analysis
16 digital channels
Easy connection to your device-under-test through the convenient design of the P6316 digital probe
MSO3000 and DPO3000 Series Oscilloscopes User Manual xiii
Preface
Conventions Used in This Manual
The following icons are used throughout this manual.
Sequence Step front-panel power Connect power
Network
USB
xiv MSO3000 and DPO3000 Series Oscilloscopes User Manual
Installation
Before Installation
Unpack the oscilloscope and check that you received all items listed as standard accessories. The following pages list recommended accessories and probes, instrument options, and upgrades. Check the Tektronix Web site (www.tektronix.com) for the most current information.
Standard Accessories
Accessory Description
MSO3000 and DPO3000 Series Oscilloscopes User Manual
MSO3000 and DPO3000 Series Oscilloscopes Documentation Browser CD
NI LabVIEW SignalExpress Tektronix Edition and Tektronix OpenChoice Desktop CD
Calibration certicate documenting traceability to national metrology institute(s), and ISO9001 quality system registration
Front-panel Overlay
For MSO3000 and DPO3000 series: Analog Probes
English (Option L0) French (Option L1) Italian (Option L2) German (Option L3) Spanish (Option L4) Japanese (Option L5) Portuguese (Option L6) Simple Chinese (Option L7) Traditional Chinese (Option L8) Korean (Option L9) Russian (Option L10) Electronic versions of documents, including
the Programmer M anual and the Technical Reference
Productivity, analysis, and documentation software
French (Option L1) Italian (Option L2) German (Option L3) Spanish (Option L4) Japanese (Option L5) Portuguese (Option L6) Simplied Chinese (Option L7) Traditional Chinese (option L8) Korean (Option L9) Russian (Option L10) One, 500 MHz, 10X passive probe per channel
Installation
Tektronix part number
071-2656-XX 071-2657-XX 071-2658-XX 071-2659-XX 071-2660-XX 071-2661-XX 071-2662-XX 071-2663-XX 071-2664-XX 071-2665-XX 071-2666-XX 063-4104-xx
063-3967-XX
––
335-1917-00 335-1918-00 335-1919-00 335-1920-00 335-1921-00 335-1922-00 335-1923-00 335-1924-00 335-1925-00 335-1926-00 P6139B
MSO3000 and DPO3000 Series Oscilloscopes User Manual 1
Installation
Standard Accessories (cont.)
Accessory Description
Front Cover Power Cord
Accessories Pouch
For MSO3000 series: Digital probe One, 16-channel digital probe
Hard plastic cover to help protect the instrument 200-5052-00 North America (Opti o n A0) Universal Euro (Option A1) United Kingdom (Option A2) Australia (Option A3) Switzerland (Option A5) Japan (Option A6) China (Option A10) India (Option A11) No power cord or AC adapter (Option A99) Pouch that attaches to the handle for carrying
probes and other accessories
Tektronix part number
161-0348-00 161-0343-00 161-0344-00 161-0346-00 161-0347-00 161-0342-00 161-0341-00 161-0349-00 ––
016-2008-00
P6316
2 MSO3000 and DPO3000 Series Oscilloscopes User Manual
Optional Accessories
Accessory Description
Aerospace serial triggering and analysis application m
odule
Audio serial triggering and analysis application
Automotive
module
serial triggering and analysis
application module
Computer triggering and analysis application module
Embedded serial triggering and analysis application module
FlexRay serial triggering and analysis
ation module
applic
Power analysis application module The power analysis module supports
Extended video application module The extended video module enables triggering
Bandwidth xed license upgrade options
PA-BNC
T
This module enables triggering on MIL-STD-1553
serial buses. Also, it provides digital views of the signal, bus views, bus decoding, search tools, and decode tables with time stamp in
formation.
The audio serial triggering and analysis module enables trig
geringonI
2
S, Left Justied (LJ),
Right Justied (RJ), and TDM buses. The automot
ive serial triggering and analysis module enables triggering on packet level information on CAN and LIN serial buses, as well as dig
ital views of the signal, bus views, bus decoding, search tools, and packet decode tables with timestamp information.
The computer triggering and analysis module enables triggering on RS-232, RS-422, RS-485 and UART s
erial buses, search tools, bus views, bus decoding in hex, binary, and ASCII, and decode tables with timestamp information.
The embedded serial triggering and analysis module enables triggering on packet level informa
tion on I
C and SPI serial buses, as
2
well as digital views of the signal, bus views, bus decoding, search tools, and packet decode
with timestamp information.
tables This module enables triggering on packet
nformation in FlexRay buses, as well as
level i digital views of the signal, bus views, packet decoding, search tools, packet decode tables
ime stamp information.
with t
rements of power quality, switching loss,
measu harmonics, ripple, modulation, safe operating area, and slew rate.
on a variety of standard HDTV signals, as
as on custom (non-standard) bi-level and
well tri-level video signals with 3 to 4,000 lines.
se products enable you to upgrade the
The bandwidth of a 100MHz or 300MHz instrument up to 500MHz when your project requirements
and higher performance.
dem
ekVPI to TekProbe II BNC Adapter
T
Tektronix part number
DPO3AERO
DPO3AUDIO
DPO3AUTO
DPO3COMP
DPO3EMBD
DPO3FL
DPO3P
EX
WR
DPO3VID
DPO3BW1T32 DPO3BW1T52
3BW1T34
DPO DPO3BW1T54 DPO3BW3T52
O3BW3T54
DP
PA-BNC
T
Installation
MSO3000 and DPO3000 Series Oscilloscopes User Manual 3
Installation
Optional Accessories (cont.)
Tektronix part
Accessory Description
TEK-USB-488 Adapter GPIB to USB Adapter TEK-USB-488 Rackmount kit Adds rackmount brackets RMD3000 Soft transit case Case for carrying instrument ACD4000 Hard transit case
MSO3000 and DPO3000 Series Oscilloscopes Service manual
MSO3000 and DPO3000 Series Oscilloscopes Application Module Installation Manual
DPO3PWR and DPO4PWR Power Measurement Module User Manual
MSO3000 and DPO3000 Series Oscilloscopes Declassication and Security Instructions
Traveling case, which requires use of the soft transit case (ACD4000)
Service information on MSO3000 and DPO3000 Series oscilloscopes
Manual 071-2524-XX
English (Option L0) French (Option L1) Italian (Option L2) German (Option L3) Spanish (Option L4) Japanese (Option L5) Portuguese (Option L6) Simple Chinese (Option L7) Traditional Chinese (Option L8) Korean (Option L9) Russian (Option L10) Describes how to sanitize or remove memory
devices from the Tektronix MSO3000 and DPO3000 oscilloscopes
number
HCTEK4321
071-2667-XX
071-2631-XX 077-0235-XX 077-0236-XX 077-0237-XX 077-0238-XX 077-0239-XX 077-0240-XX 077-0241-XX 077-0242-XX 077-0243-XX 077-0244-XX 077-0307-XX
The MSO3000 and DPO3000 Series oscilloscopes work with multiple optional probes. (See page 8, Connecting Probes.) Check the Tektronix Web site (www.tektronix.com) for the most current information.
Related Documentation
MSO3000 and DPO3000 Series Oscilloscopes Programmer Manual
MSO3000 and DPO3000 Series Oscilloscopes Technical Reference Manual
4 MSO3000 and DPO3000 Series Oscilloscopes User Manual
Describes commands for remote control of the oscilloscope. Available electronically on the Documentation Browser CD or for download from www.tektronix.com/manuals
Describes the oscilloscope specications and performance verication procedure. Available electronically on the Documentation Browser CD or for download from www.tektronix.com/manuals
077-0301-XX
077-0300-XX
Operating Considerations
Installation
MSO3000 and DP
O3000 Series
Oscilloscopes
Power Supply Input Voltage: 100 V to 240 V ± 10% Power Supply Input Power Frequency:
50/60 Hz at 100 V to 240 V 400 Hz ± 10% at 115 V
Power Consumption: 120 W maximum Weight: 4.2 kg (9.2 lbs), standalone instrument Height, including feet but not handle:
203.2 mm (8 in) Width, 416.6 mm (16.4 in) Depth, 147.4 mm (5.8 in) Clearance: 51 mm (2 in)
Temperature: Operating: 0 °C to +50 °C (+32 °F to +122 °F) Nonoperating: -40 °C to +71 °C (-40 °F to +160 °F)
Humidity: Operating: 5% to 95% relative humidity (RH) at up to +30 °C Operating: 5% to 45% relative humidity (RH) above +30 °C up to + 50 °C, non-condensing, and as limited by a Maximum Wet-Bulb Temperature of +38 °C (derates relative humidity to 45 % RH at +50 °C) Non-operating: 5% to 95% Relative Humidity (RH) at up to +30 °C Non-operating: 5% to 45% Relative Humidity (RH) above +30 °C up to +50 ° C, non-condensing, and as limited by a Maximum Wet-Bulb Temperature of +38 °C (derates relative humidity to 27% RH at 60 C)
MSO3000 series
DPO3000 series
Altitude: Operating: 3,000 m (9,843 ft) Nonoperating Altitude: 12,000 m (39,370 ft)
Random Vibration: Operating: 0.31 G Non-operating: 2.46 G
Pollution Degree: 2, Indoor use only
Acquisition System: 1 M The maximum input voltage: At front-panel connector, 300 V circuits directly connected to the low-voltage installation.
MSO3000 and DPO3000 Series Oscilloscopes User Manual 5
, 5 – 500 Hz, 1 0 minutes per axis, 3 axes (30 minutes total)
RMS
, 5 – 500 Hz, 10 minutes per axis, 3 axes (30 minutes total)
RMS
, Installation Category II; for measurements performed on
RMS
Installation
Acquisition System: 50 and 75 The maximum input voltage: 5 V to Installati
on Category II, III, or IV circuits.
RMS
with a peak at ±20 V. For Installation Category I measurements. Not for connection
Acquisition
System: D igital Inputs
The maximum input voltage at the input for the digital probe is +30 V to -20 V peak.
Aux In: 1 M The maximum input voltage: At the front-panel connector, 300 V circuits di
CAUTION. T
Total Probe Power
rectly connected to the low-voltage installation.
o ensure proper cooling, keep the sides and rear of the instrument clear of obstructions.
:
, Installation Category II; for measurements performed on
RMS
If the total probe power requirements exceed the available power from the oscilloscope, connect the external AC adapter (Tektronix part number 119-7465-XX) to the rear-panel Probe Power connector.
Maximum Probe Power Available Per Channel (3 or 5 TekVPI Interfaces): 5 V ± 5%, 50 mA max
., 250 mW max.
12 V ± 10%, 2 A max., 24 W max.
P6139B Passive Probe
Maximum tip input voltage: 300 V
Temperature: Operating: -15 °C to +65 °C ( +5 °F to +149 °F) Nonoperating: -62 °C to +85 °C ( -80 °F to +185 °F)
CAT II and DC
RMS
Altitude: Operating: 3.0 km (10,000 ft) maximum Nonoperating: 15 km (50,000 ft) maximum
Humidity: Operating: 5% to 95% relative humidity (%RH) up to +30 ° C, 5% to 75% RH above +30 °C up to +65 °C. Noncondensing. Non-operating: 5% to 45% RH above +65 °C up to +85 °C. Noncondensing.
MSO3000 Series Oscilloscope with a P6316 Digital Probe
Threshold Accuracy: ±(100 mV + 3% of threshold)
Threshold Range: +25 V to –15 V.
Maximum nondestructive input signal to probe: +30 V to -20 V
Minimum signal swing: 500 mV
peak-to-peak
6 MSO3000 and DPO3000 Series Oscilloscopes User Manual
Input resistance: 101 K
Installation
Input capacit
Temperature: Operating: 0 Nonoperating: -40 °C to +71 °C (-40 °F to +160 °F)
Altitude: Operating: 3,000 m (9,843 ft) maximum Nonoperating: 12,000 m (39,370 ft) maximum
Pollution Degree: 2, Indoor use only
Humidity: 5% to 95% relative humidity
ance: 8.0 pF typical
°Cto+50°C(+32°Fto+122°F)
Cleaning
Inspect the oscilloscope and probes as often as operating conditions require. To clean the exterior surface, perform the following steps:
1. Remove loose dust on the outside of the oscilloscope and probes with a lint-free cloth. Use care to avoid scratching the clear glass display lter.
2. Use a soft cloth dampened with water to clean the oscilloscope. Use an aqueous solution of 75% isopropyl alcohol for more efcient cleaning.
CAUTION. Avoid getting moisture inside the unit during external cleaning. Use only enough cleaning solution to dampen
the cloth or swab.
CAUTION. To avoid damage to the surface of the oscilloscope or probes, do not use any abrasive or chemical cleaning
agents.
MSO3000 and DPO3000 Series Oscilloscopes User Manual 7
Installation
Connecting Probes
The oscilloscope supports probes with the following:
1. Tektronix Versatile Probe Interface (TekVPI)
These probes support two-way communication with the oscilloscope through on-screen menus and remotely through programmable support. The remote control is useful in applications like ATE where you want the system to preset probe parameters.
2. Tektronix Versatile Probe Interface (TekVPI) for Passive Probes
These probes build upon the functionality of the TekVPI interface. Each probe is matched with the corresponding oscilloscope channel, allowing the oscilloscope to optimize the signal input path. This provides AC compensation across the frequency band.
3. TPA-BNC Adapter The TPA-BNC Adapter allows you to
use TEKPROBE II probe capabilities, such as providing probe power, and passing scaling and unit information to the oscilloscope.
4. BNC Interfaces Some of these use TEKPROBE
capabilities to pass the waveform signal and scaling to the oscilloscope. Some only pass the signal and there is no other communication.
5. Digital Probe Interface (MSO3000 Series only)
The P6316 probe provides 16 channels of digital (on or off state) information.
For more information on the many probes available for use with MSO3000 and DPO3000 Series oscilloscopes, r efer to www.tektronix.com.
8 MSO3000 and DPO3000 Series Oscilloscopes User Manual
Loading...
+ 166 hidden pages