Tektronix DP-AUX Controller User manual

DP-AUX DisplayPort A
ZZZ
UX Control
Instructions
*P071260900*
071-2609-00
Overview
The DP-AUX DisplayPort AUX Control lets you control the DisplayPort AUX channel. Use the DP-AUX hardware and software along with Tektronix test equipment to perform debug and characterization tests on DisplayPort sink (Rx) and source (Tx) devices.
Prerequisites
oft Windows XP 32-bit operating
Micros system (for the DP-AUX DisplayPort AUX
lsoftware).
Contro
Tektronix DPO/DSA70000 Series oscilloscope (for source testing).
Tektronix AWG7000 Series Arbitrary Waveform Generator (for sink testing).
Sink test board xture (Tektronix part number includes GPPO to SMA adapter cables for the AUX
Source test board xture (Tektronix part number ET-DP-TPA-STX). This part number includes a source test board xture, the sink test board xture ET-DP-TPA-S, and GPPO to SMA adapter cable s for the AUX p and n channels.
ET-DP-TPA-S). This part number
p and n channels.
Phase-matched S test board xture DisplayPort lane signals to the test instr signal path compensation (SPC) and cable deskew ut skew between the SMA cables. See the oscilloscope u running SPC and deskew programs.
MA cables to connect the
ument. Run the oscilloscope
ilities to compensate for
ser manual for information on
Install the DP-AUX Control Software and Hardware Drivers
NOTE. Do not connect the DP-AUX hardware to the PC or test equipment until directed to do so in these instructions.
1. Insert the DP-AUX DisplayPort AUX Control software CD disc into the CD drive of your PC, Tektronix DPO/DSA70000 Series oscilloscope, or Tektronix AWG7000 Series Arbitrary Waveform Generator. Follow the on-screen instructions. If the installation software does not run, double-click the setup.exe le on the CD drive.
2. The DP-AUX install program requires that Microsoft Windows Installer v3.1 (or greater) and Microsoft .NET Framework v3.5 (or greater) be installed on the target PC or test equipment. If Windows Installer and .NET Framework are installed on the target PC or test equipment, the installation process begins installing the DP-AUX software and drivers.
If either or both of the Microsoft applications are not installed, the DP-AUX installer will install them, one at a time (rst Windows Installer, then .NET Framework). You will need to reboot your system if Windows Installer 3.1 was installed. The .NET Framework install does not require a reboot.
3. Click Next on each DP-AUX Installation screen to accept the default settings and begin installing the DP-AUX software.
4. Click Continue Anyway if you are prompted from a dialog box stating that the DP-AUX drivers are not certied by Microsoft.
5. The Installation Complete dialog box contains instructions for connecting the DP-AUX hardware to the PC or test equipment. Click Print to print the instructions (your PC or test equipment must be connected to a printer).
6. Click Finish to complete the DP-AUX software and driver install.
7. Connect a USB cable between the DP-AUX hardware and the PC or test equipment on which you just installed the DP-AUX software. The PC opens the Found New
Hardware dialog box.
8. Foll
ow the instructions printed from the
Installation Complete dialog box in step 5.
Using The DP-AUX
NOTE. Install the DP-AUX software before connecting the test equipment.
1. Use the diagram to connect the DP-AUX hardware for Si testing.
2. On the PC or test instrument, click Start > DisplayPort AUX Controller > DP-AUX Control App to start the DP-AUX software.
3. Click Help > DP-AUX Online Help to open
the DP-AUX online help for information on connecting the DUT lane channels to the test instrument and running sink and source tests.
4. Select File > E DP-AUX application.
Controller
DP-AUX hardware to the PC or
nk (Rx) or Source (Tx)
xit to close and exit the
EMC Compliance
EC Declaration of Conformity – EMC
Meets intent of D Electromagnetic Compatibility. Compliance was demonstrated t listed in the Ofcial Journal of the European Communities:
EN 61326-1 2006
electrical equipment for measurement, control and laboratory
CISPR 11:2003. Radiated emissions, Group 1, Class A
IEC 61000-4-2:2001. Electrostatic discharge immunity
IEC 61000-4-3:2002. RF electromagnetic eld immunity
1
This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2
Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object.
European Contact
Tektronix UK, Ltd
Western Peninsula
Western R o a d
Bracknell, RG12 1RF
United Kingdom
Australia / New Zealand Declaration of Conformity –EMC
Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA:
CISPR 11:2003. Radiated emissions, Group 1, Class A, in accordance with EN 61326-1 2006
irective 2004/108/EC for
o the following specications as
. EMC requirements for
12
use.
Environmental C
onsiderations
Product End-of-Life Handling
Observe the foll
owing guidelines when recycling
an instrument or component:
Equipment Recycling. Production of this equipment requ
ired the extraction and use of natural resources. The equipment may contain substa
nces that could be harmful to the environment or human health if improperly handled at the p
roduct’s end of life. In order to avoid release of such substances into the environment an
d to reduce the use of natural resources, we encourage you to recycle this product in an a
ppropriate system that will ensure that most of the materials are reused or recycled appropriatel
y.
This symbol indicates that
this product complies with the
applicable European Union
requirements according to
Directives 20
2006/66/EC on waste electrical
and electronic equipment (WEEE)
and batteries. For information
about recycling options, check
the Support/Service section
of the Tektro
(www.tektronix.com).
02/96/EC and
nix Web site
Restriction of Hazardous S ubstances
This product
has been classied as Monitoring and Control equipment, and is outside the scope of the 2002/9
5/EC RoHS Directive.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, Oregon 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to nd contacts in your area.
opyright © Tektronix, Inc. All rights reserved. www.tektronix.com
C
Loading...