2260B Series Multi-Range
Programmable DC Power Supplies
Quick Start Guide
071305503 June 2022
tek.com/keithley
*P071305503*
071305503
Standard
Accessories
Part number
Description
196353000
174627900
020312300
020316400
ERRATA
Please replace the “Accessories” section on page 11 through page
13 of the quick start guide with the following replacement:
Accessories
Please check the contents before using the 2260B.
2260B-30/80 Accessories
Test Leads x1(10AWG, Max. 45A,
Max.600V)
USB Cable
Basic Accessories Kit:(360W, 720W)
M4 terminal screws and washers x2, M8
terminal bolts, nuts and washers x2, Air
filter x1, Analog control protection
dummy x1, Analog control lock lever x1,
Output terminal cover (top & bottom)
Basic Accessories Kit:(1080W)
M4 terminal screws and washers x2, M8
terminal bolts, nuts and washers x2, Air
filter x1, Analog control protection
dummy x1, Analog control lock lever x1,
Output terminal cover (top & bottom),
Strain relief
071305503
PWRKI A*_
071305700
001163200
Quick Start Guide
Power cord
China RoHS Declaration
Calibration of Traceable Certificate
001163300
Packing Check List
Optional
Accessories
Part number
Description
2260-001
Accessory Kit:
Pin contact x10, Socket x1, Protection
cover x1
2260-002
Simple IDC Tool
2260-003
Contact Removal Tool
2260-004
Basic Accessory Kit:
M4 terminal screws and washers x2, M8
terminal bolts, nuts and washers x2, Air
filter x1, Analog control protection
dummy x1, Analog control lock lever x1,
Output terminal cover (top & bottom),
Strain relief
2260-005
Cable for 2 units in Series connection.
2260-006
Cable for 2 units in Parallel connection.
2260-007
Cable for 3 units in Parallel connection.
2260-008
Test Lead Set with Lugs
2260B-EXTERM
Extended terminal
2260B-RMK-JIS
Rack mount adapter (JIS)
2260B-RMK-EIA
Rack mount adapter (EIA)
2260B-GPIB-USB
GPIB to USB adapter
Download
Name
Description
keithley_2260B.inf
USB driver
2260B-250/800 Accessories
Standard
Accessories
Part number
Description
196353900
174627900
020315700
020316500
PWRKI A*_
071305700
001163200
001163300
Test Leads x1(20AWG, Max. 9A, Max.
3kV)
USB Cable
Basic Accessories Kit: (360W, 720W)
Air filter x1, Analog control protection
dummy x1, Analog control lock lever x1,
Output terminal cover (top & bottom),
High voltage output terminal
Basic Accessories Kit: (1080W)
Air filter x1, Analog control protection
dummy x1, Analog control lock lever x1,
Output terminal cover (top & bottom),
High voltage output terminal, Strain relief
071305503
Quick Start Guide
Power cord
China RoHS Declaration
Calibration of Traceable Certificate
Packing Check List
Optional
Accessories
Part number
Description
2260-001
Accessory Kit:
Pin contact x10, Socket x1, Protection
cover x1
2260-002
Simple IDC Tool
2260-003
Contact Removal Tool
2260-005
Cable for 2 units in Series connection.
2260-006
Parallel operation cable for 2 units.
2260-007
Parallel operation cable for 3 units.
2260-009
Test Leads (for High Voltage)
2260-010
Basic Accessories Kit:
Air filter x1, Analog control protection
dummy x1, Analog control lock lever x1,
Output terminal cover (top & bottom),
High voltage output terminal, Strain relief
2260B-EXTERMHV
Extended terminal (For 250V/800V HV
models)
2260B-RMK-JIS
Rack mount adapter (JIS)
2260B-RMK-EIA
Rack mount adapter (EIA)
2260B-GPIB-USB
GPIB to USB adapter
Download
Name
Description
keithley_2260B.inf
USB driver
Series 2260B
Multi-Range Programmable DC Power Supplies
QUICK START GUIDE
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent.
The information in this manual was correct at the time of printing.
However, we continue to improve products and reserves the rights to
change specification, equipment, and maintenance procedures at any
time without notice.
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the 2260B or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
SAFETY INSTRUCTIONS
This chapter contains important safety
instructions that you must follow during
operation and storage. Read the following before
any operation to insure your safety and to keep
the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
4
SAFETY INSTRUCTIONS
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
General
Guideline
CAUTION
Do not place any heavy object on the 2260B.
Avoid severe impact or rough handling that
leads to damaging the 2260B.
Do not discharge static electricity to the 2260B.
Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening.
Do not disassemble the 2260B unless you are
qualified.
(Measurement categories) EN 61010-1:2010 and EN 61010-2-030
specify the measurement categories and their requirements as
follows. The 2260B falls under category II.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Power Supply
WARNING
To avoid electrical shock connect the protective
grounding conductor of the AC power cord to
an earth ground.
Cleaning the
2260B
Disconnect the power cord before cleaning.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Safety Guidelines
5
2260B Series Quick Start Guide
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 85%
Altitude: < 2000m
Temperature: 0°C to 50°C
(Pollution Degree) EN 61010-1:2010 and EN 61010-2-030 specify the
pollution degrees and their requirements as follows. The 2260B falls
under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
nor humidity is controlled.
Storage
environment
Disposal
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.
Location: Indoor
Temperature: -15°C to 70°C
Relative Humidity: <90%, no condensation
6
SAFETY INSTRUCTIONS
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
Power cord for the United Kingdom
When using the power supply in the United Kingdom, make sure
the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed
as follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the
terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment
or contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable
of 0.75mm2 should be protected by a 3A or 5A fuse. Larger
conductors would normally require 13A types, depending on the
connection method used.
Any exposed wiring from a cable, plug or connection that is
engaged in a live socket is extremely hazardous. If a cable or plug is
deemed hazardous, turn off the mains power and remove the cable,
any fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.
7
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.