Series 2200 Programmable DC Power Supplies
Ripple and noise (20 Hz to 7 MHz)
Setting accuracy (using remote sense, 25°C ±5°C)
Keithley Instruments
28775 Aurora Road
Cleveland, Ohio 44139
Specifications
1-800-935-5595
tek.com/keithley
Specification conditions
This document contains specifications for the Models 2200-20-5, 2200-30-5, 2200-32-3, 2200-60-2, and 2200-72-1
Programmable dc Power Supplies. Specifications are the standards against which the Models 2200-20-5,
2200-30-5, 2200-32-3, 2200-60-2, and 2200-72-1 are tested. Upon leaving the factory, the Models 2200-20-5,
2200-30-5, 2200-32-3, 2200-60-2, and 2200-72-1 meet these specifications. Typical values are not warranted and
are provided solely as useful information.
Model-specific specifications
Voltage
< 1 mV
RMS
SPEC-2200 Rev. B May 2020
< 1 mV
RMS
< 1 mV
RMS
*PSPEC-2200B*
< 1 mV
RMS
< 1 mV
RMS
1

Series 2200 Programmable DC Power Supplies Specifications
Readback accuracy (25 °C ± 5 °C)
Voltage transient response – settling time
<400 μs to within 75 mV following a change from 0.1 A to 1 A
<Setting voltage from 0% to 100%; voltage change from 10% to 90% < 35 ms
Falling
< Setting voltage from 100% to 0%; voltage change from 90% to 10% < 200 ms
NOTE:
USB: Type B connector, USB-TMC compatible
GPIB:
Vacuum fluorescent display
Up to seven lists can be defined, each with up to 80 steps. Each step includes a voltage limit and
Removable screw terminal block carries the following signals:
Up to 100 V (dc + peak ac) between protective earth (safety ground) and any output terminal
Model-specific specifications
NOTE: Specification does not include command decode time.
Specification does not include command decode time.
(typical)
General specifications
a current limit. For continuous sequences, each step also includes a duration.
and control:
IEEE-488.2 compliant
• Output channel: Duplicates the front panel outputs
• Remote sense lines: Connection for remote sense
• Control input: Multifunction TTL input, which can function as a trigger input, output control
line, or digital input
• Status Output: Multifunction TTL output, which can function as a fault indication or digital
output
2
SPEC-2200 Rev. B May 2020