Tektronix products are covered by U.S. and foreign patents, issued and
pending. Information in this publication supercedes that in all previously
published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects
in materials and workmanship for a period of three (3) years from the date of shipment. If a
product proves defective during this warranty period, Tektronix, at its option, either will
repair the defective product without charge for parts and labor, or will provide a
replacement in exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the
defect before the expiration of the warranty period and make suitable arrangements for the
performance of service. Customer shall be responsible for packaging and shipping the
defective product to the service center designated by Tektronix, with shipping charges
prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to
a location within the country in which the Tektronix service center is located. Customer
shall be responsible for paying all shipping charges, duties, taxes, and any other charges for
products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or
improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish
service under this warranty a) to repair damage resulting from attempts by personnel other
than Tektronix representatives to install, repair or service the product; b) to repair damage
resulting from improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a
product that has been modified or integrated with other products when the effect of such
modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER
WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS
DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY
TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND
EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF
THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR
HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
General Safety Summary
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected to
it. To avoid potential hazards, use this product only as
specified.
Only qualified personnel should perform service procedures.
To Avoid Fire or Personal Injury
Use Proper Power Cord
Use only the power cord specified for this product and
certified for the country of use.
Connect and Disconnect Properly
Do not connect or disconnect probes or test leads while they
are connected to a voltage source.
Ground the Product
This product is grounded through the grounding conductor of
the power cord. To avoid electric shock, the grounding
conductor must be connected to earth ground. Before making
connections to the input or output terminals of the product,
ensure that the product is properly grounded.
Observe All Terminal Ratings
To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further
ratings information before making connections to the product.
1740A/1750A Series Waveform/Vector Monitor User Manual
i
General Safety Summary
The common terminal is at ground potential. Do not connect
the common terminal to elevated voltages.
Do Not Operate Without Covers. Do not operate this
product with covers or panels removed.
Use Proper Fuse. Use only the fuse type and rating speci-
fied for this product.
Avoid Exposed Circuitry. Do not touch e xposed connec-
tions and components when power is present.
Do Not Operate With Suspected Failures. If you suspect
there is damage to this product, have it inspected by qualified
service personnel.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation.
tion instructions for details on installing the product so it has
proper ventilation.
Safety Terms and Symbols
Terms in This Manual. These terms may appear in this
manual:
WARNING. Warning statements identify conditions or practices
that could result in injury or loss of life.
Refer to the manual’s installa-
ii
1740A/1750A Series Waveform/Vector Monitor User Manual
General Safety Summary
CAUTION. Caution statements identify conditions or practices
that could result in damage to this product or other property.
Terms on the Product. These terms may appear on the
product:
DANGER indicates an injury hazard immediately accessible
as you read the marking.
WARNING indicates an injury hazard not immediately
accessible as you read the marking.
CAUTION indicates a hazard to property including the
product.
Symbols on the Product. These symbols may appear on
the product:
CAUTION
Refer to
Manual
Not suitable for
connection to
the public tele-
communica-
tions network
WARNING
High Volt-
age
Double
Insulated
Protective
Ground (Earth)
Te r mi nal
1740A/1750A Series Waveform/Vector Monitor User Manual
iii
General Safety Summary
iv
1740A/1750A Series Waveform/Vector Monitor User Manual
1740A/1750A Series Waveform/Vector Monitor User Manual
This user manual is one of a set of two manuals that document the
Tektronix 1740A/1750A-Series Waveform/Vector monitors. To
purchase a service manual, please refer to “Contacting Tektronix” on
Page xiv for address and phone number information.
User Manual
Instrument controls and readouts appear in ALL CAPITALS.
Topics covered in the user manual are as follows:
Introduction
Getting Started
Operation Basics
Preface
Making Measurements
Appendix A
electrical and mechanical.
Appendix B describes remote control interfaces.
Appendix C covers routine service procedures, such as
replacing fuses and graticule light bulbs.
The appendixes are followed by a glossary of specialized
terms and an index.
provides instrument specifications, both
1740A/1750A Series Waveform/Vector Monitor User Manualxi
Preface
Service Manual
Topics covered in the service manual are as follows:
Specifications
Operating Information
Theory of Operation
Performance Verification
Adjustment Procedures
Maintenance
Options
Electrical Parts List
Diagrams
Mechanical Parts List
xii
1740A/1750A Series Waveform/Vector Monitor User Manual
Preface
1750A Waveform / Vector Monitor.
1740A/1750A Series Waveform/Vector Monitor User Manual
xiii
Preface
Contacting Tektronix
Phone1-800-833-9200*
AddressTektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Web sitewww.tektronix.com
Sales
support
Service
support
Technical
support
*This phone number is toll free in North America. After office
hours, please leave a voice mail message.
Outside North America, contact a Tektronix sales office or
distributor; see the Tektronix web site for a list of offices.
1-800-833-9200, select option 1*
1-800-833-9200, select option 2*
Email: techsupport@tektronix.com
1-800-833-9200, select option 3*
6:00 a.m. -- 5:00 p.m. Pacific time
xiv
1740A/1750A Series Waveform/Vector Monitor User Manual
Introduction
The 1740A/1750A--Series are combination waveform/vector
monitors in half-rack size packages. The 1740A--Series
provides all basic waveform monitor and vectorscope functions; the 1750A--Series provides the same functions with
SCH measurement capabilities added. The following products
are available:
Applications
Product Description
1740A / 1750ANTSC
1741A / 1751APAL
1745A / 1755ANTSC / PAL (dual-standard)
Typical applications for these monitors include video signal
monitoring in camera control units, VTR bridges, production
switcher consoles, mobile vans and field production systems.
The 1740A--Series is well-suited for port able applications
where a small, lightweight monitor is needed, and SCH
capability is not required. It is appropriate for many VTR
bridge applications, providing remote control and 90/100 Hz
sweeps for D-2 servo observation.
The 1750A--Series is useful in the composite edit suite,
providing all 1740A--Series features, plus the Tektronix polar
SCH display to match color subcarrier-to-horizontal sync
timing and color framing among edit sources.
1740A/1750A Series Waveform/Vector Monitor User Manual1-1
HLongitudinal time code display mode for editing applica-
tions
HSCH and Color Framing Display (1750A--Series only)
HExternal staircase from a camera control unit can be
selected remotely.
HInternal video filters provide specialized measurements,
with dual or triple filter modes available in
OVERLAY.
HEight video inputs can be individually displayed or
selected in various combinations.
HRemote interface and serial RS232 interface.
Description of Features
Menu
A notable feature of these monitors is t he m enu-assisted
operation. An expanded feature set is possible through the
use of menus and multi-use controls and buttons. When the
operator selects a menu item, such as
CURSORS
label shows the current function of the controls.
, VARIABLE G AIN,orLINE SELECT, an on-screen
PARADE or
VOLTAGE/TIMING
1-2
Many instrument configurations that required moving internal jumpers or wire straps in the 1740/1750--Series monitors
are made through an on-screen menu in the 1740A/ 1750A-Series. The operator can also recal l up to 10 front-panel
setups through the
1740A/1750A Series Waveform/Vector Monitor User Manual
RECALL menu; 9 recalls are user-program-
Product Description
mable and 1 is factory-programmed. The FILTER menu also
provides a choice of four filters in addition to flat. Two
combination filtering modes can be displayed in
PARADE. Refer to “Using the Menus” on page 3-5 for more
OVERLAY or
menu information.
CRT
The monitors have a bright, post-accelerated CRT with
lighted internal graticule. The parallax-free internal graticule
structure contains targets and markings for both the vector
and waveform functions. A white phosphorus CRT is optional; refer to page 1-6 for details.
The bright CRT allows use in high ambient light conditions,
such as those encountered in field production applications.
Calibrator
Vertical and horizontal instrument gain can be set using the
calibrator signal. The 1 Volt calibrator signal is available in
100 kHz and F
More Information
HStandard and optional accessories are listed in the
Accessories section, which follows this product de scription.
HInstrument options are listed on page 1-5.
HA complete listing of instrument specifications begi ns on
Appendix page A-1.
(color subcarrier) rates.
SC
1740A/1750A Series Waveform/Vector Monitor User Manual
1-3
Product Description
1-4
1740A/1750A Series Waveform/Vector Monitor User Manual
White phosphor CRT and power cord options are the only
options currently available for the 1740A/1750A--Series.
Field upgrade kits listed in this section can also be used with
these monitors.
Power Cord Options
Any of the following power cord options can be ordered for
the 1740A/1750A--Series. If no power cord option is specified, instruments are shipped with a North American 125 V
power cord and one replacement fuse.
Unless otherwise specified, power cords for use in North
America are UL listed and CSA certified. Cords for use in
areas other than North America are approved by at least one
test house acceptable in the country to which the product is
shipped.
Options
Option A1. Power, Universal Europe, 220 V/16 A
(Locking Power Cord)
Option A2. Power, United Kingdom, 240 V/15 A
(Power Cord)
Option A3. Power, Australia, 240 V/10 A
(Power Cord)
Option A4. Power, North America, 250V/10 A
(Power Cord)
Option A5. Power, Swiss, 240 V/6 A
(Power Cord)
1740A/1750A Series Waveform/Vector Monitor User Manual1-5
Options
CRT Options
The standard instrument is shipped with a P31 (green)
phosphor CRT installed. If Option 74 is ordered, the instrument is shipped with a P4 (white) phosphor CRT installed.
The Option 74 CRT part numbers are given in the service
manual, at the end of the Replaceable Electrical Parts List.
1-6
1740A/1750A Series Waveform/Vector Monitor User Manual
Standard Accessories
These accessories are included with the product:
1Manual, user: 1740A/1750A--Series
(070--8470--XX)
1Cable assembly, power: United States and Japan
only (161--0216--XX)
1Cable assembly, power: all other countries
(161--0066--XX)
1Fuse, cartridge: 3AG, 2A, 250V, fast-blow
(159--0021--00)
4Light bulbs: graticule scale (150--0168--00). See
page C-1 for replacement instructions.
Accessories
4Air filters: fan (378--0335--00). See page C-1 for
replacement instructions.
This accessory is installed on the product:
1CRT filter: smoke gray (378--0258--00)
Optional Accessories
Manual, service: 1740A/1750A/1760-- Series
(070--8469--XX)
Camera, C9 Option 20
Viewing Hood (016--0475--00)
Front-Panel Cover (200--3897--01)
1740A/1750A Series Waveform/Vector Monitor User Manual1-7
Accessories
Field Upgrade Kits
1700F00 Plain Cabinet — This plain metal half-rack
size cabinet is painted silver-gray. Ventilating holes in top,
bottom, and sides of the cabinet allow heat generated within
the instrument to dissipate.
1700F02 Carrying Case — This portable cabinet is
similar to the 1700F00, but has feet, carrying handle, flipstand, and front cover.
1700F05 Side-by-Side Rack Adapter — The
1700F05 allows the user to mount two half-rack width
instruments in a standard 19--inch rack.
1700F06 Blank Panel — If only one section of a
1700F05 is used, the 1700F06 Blank Panel can be inserte d in
the unused section to improve appearance and air flow.
1700F07 Utility Drawer — When only one side of a
1700F05 is used, this utility drawer can be installed in the
unused section to provide storage. The drawer opens and
closes freely, unless latched for transport.
Ordering — These items can be ordered with the monitor,
or purchased through a Tektronix field office or distributor.
When ordering, include both the name and number of the
Field Upgrade Kits.
Installation — Cabinet installation instructions begin on
page 1-12. Dimensional drawings are also shipped with each
cabinet. For more information, contact a Tektronix field
office or distributor.
1-8
1740A/1750A Series Waveform/Vector Monitor User Manual
Installation
Unpacking
Save the shipping carton and packing materials (including
anti-static bag) in case it becomes necessary to ship the
instrument to a Tektronix Service Center for service or repair.
Accessories
Check that the following accessory items are included:
HUser Manual
HService Manual
Note: The Service Manual is an optional accessory
that must be ordered to be received.
HPower Cord
HReplacement Fuse Cartridge (1)
HReplacement Graticule Light Bulbs (4)
HReplacement Air Filters for Fan (4)
Repackaging for Shipment
If it becomes necessary to ship the instrument to a Tektronix
Service Center for service or repair, follow these instructions
for repackaging:
1.Attach a tag to the instrument showing: the owner,
complete address and phone number of someone at your
firm who can be contacted, the instrument serial number
and a description of the required service.
2.Package the instrument in the original packaging materials. If the original packaging materials are not available,
follow these directions:
1740A/1750A Series Waveform/Vector Monitor User Manual1-9
Installation
a.Obtain a carton of corrugated cardboard having
inside dimensions six or more inches greater than
the dimensions of the instrument. Use a shipping
carton that has a test strength of at least 275 pounds.
b.Surround the instrument with a protective bag
(anti-static preferred). For instruments which are
not in a cabinet, wrap a cardboard piece around the
bagged instrument to protect components.
c.Pack dunnage or urethane foam between the instru-
ment and the carton. If using Styrofoam kernels,
overfill the box and compress by closing the lid.
There should be three inches of tightly packed
cushioning on all sides of the instrument.
3.Seal the carton with shipping tape, industrial stapler, or
both.
Electrical Installation
Power Source
These monitors are designed to operate from a single-phase
power source having one of its current-ca rrying conductors at
or near earth ground (the neutral conductor). Only the line
conductor is fused for over-current protection. Systems that
have both current-carrying conductors live with respect to
ground (such as phase-to-phase on multiphase systems) are
not recommended as power sources. A protective ground
connection by way of the grounding conductor in the power
cord is essential for safe operation.
When power is supplied, line voltage will be
present in the instrument, even if the
is set to
STANDBY.
NOTE
POWER switch