Timing Display for Measuring Signal Timing between Each Input and the
Reference
VITC or LTC Time Code Decode and Display
LTC Waveform Display for Longitudinal Time Code Amplitude and
Synchronization Monitoring
Screen Capture for Pictures and Traces Facilitate Reference Setting,
Troubleshooting, and Documentation Tasks
Video Session, Alarm Status, and Error Logging for Quick Identification
and Easier Correction of Problems
User Interface Tools
Four-tile FlexVu Display Capability
XGA Display with Full-screen Picture Display and Picture Thumbnail
for Easy Signal So urce Verification
Ethernet Interface for Convenient Freeze Capture and Error Log
Features & Benefits
Inputs and Formats
Analog C
Auto Format Detection
Four Pa
Monitoring Capabilities
omposite (PAL and NTSC) and Component Video Support with
ssive Loopthrough Analog Composite Signal Inputs
Download
USB Port Enables Screen-capture Download
32 User Presets for Quick Recall of Commonly Used Configurations
Additional XGA Outpu t for Instrument Display on External Monitor
Picture Monitor Output for Analog Composite Signal
Ground-closure for Remote Selection of Input or Preset Recall
Waveform Display S upports Composite or Component Video for White
and Black Balance and Level Checking
Vector Display for Analog Composite Signal Allows System Setup to
Specific Chroma Values
SCH Display for Color Subcarrier-to-Horizontal Sync Timing and Color
Framing Matching among Edit Sources
Applications
Camera Alignment and Analog Video Equipment Setu p
Compliance Checking in Distribution and Broadcast
Content QA of Composite and Component Video in Production and
Postproduction
Data Sheet
The 1741 C is the latest analog waveform monitor from Tektronix that
features user interface tools to simplify operations. Its precise displays
provide hi
NTSC) or component systems.
This inst
waveform, vector, SCH, and picture functions. The input ports can also be
used for RGB signals.
The 4-tile FlexVu display an d convenient picture thumbnail maximize the
versatility of the 1741C.
For c amera alignment, the user can display one, two, three, or four
waveforms simultaneously and overlay just as many vector displays, thus
facilitating monitoring of multiple cameras during content acquisition.
Powerful tools such as timing display, VITC, or LTC decode, freeze capture,
video session, alarm status, and error log allow for deeper signal inspection
to enable superior video production and delivery quality.
gh-quality monitoring for traditional analog composite (PAL and
rument supports four analog composite signal inputs with
Ease of Use
The Intuitive User Interface provides backlit buttons.
configurable presets allow users to recall commonly used
32 userconfigurations tailored to your personal work practices.
For remo
selection of input or preset recall.
The user
The error log can be downloaded using a web browser.
te opera tion, the Ground-closure Interface allows for remote
can download screensho ts using the USB or Ethernet port.
The unit provides an XGA output for instrument display on an external
monitor and picture monitor output for analog composite signals.
Time and voltage cursors in waveform display c a n be used as reference
points or to measure values. User-defined labels allow for easy
identification of input sources on the screen.
See and Solve with Tektronix Displays
The “See and Solve” displays in Tektronix video mon itors simplify video
monitoring tasks such as equipment setup, error detection, and content
correction allowing to detect errors at a glance and troubleshoot them
efficiently.
The FlexVu 4-tile display provides maximum flexibility to increase your
productivity. With FlexVu, you can create a multiview display tailored to your
specific needs and work practices.
The Video Session, Alarm Status, and Error Lo g displays are effective tools
to verify the format and quality of the signal and allow for efficient detection
and correction of errors by providing key conte nt information at a glance.
The error log captures up to 10,000 events and can be easily downloaded
using a web browser.
The freeze function on the 1741C allows comparing of the frozen display to
the live signal, facilitating tasks such as reference setting. A bitmap of the
display can be downloaded using a web browser for easy documentation.
With 32 user-configurable presets, operators can recall commonly used
configurations for faster setup of the 1741C.
2 www.tektronix.com
Analog Dual-Standard Waveform Mo nitor — 1741C
The Line Select provides a line marker in full-screen and thumbnail picture
modes.
With the time and voltage cursors in the waveform display, users can easily
reference points or measure values. Users can also define labels to quickly
identify the in
put sources active on the waveform display.
Vector Display
The vector d isplay is offered with selectable 75% and 100% targets.
Each display automatically selects the appropriate graticule based on the
input format.
The vector display offers user-selectable graticules.
Sharp Waveform Display –
Clear Measurements
Tektronix displays offer the sharpest CRT-like trace quality for clear
waveform monitoring without pixelation distortions. With several sweep
rates and easy control of vertical gain and horizontal magnification, you can
efficiently monitor and measure video waveform parameters.
Full horizontal timing flexibility is provide d with 1Line, 2Line, 1Field, and
2Field sweep modes, with or without magnification.
Both fixed and variable vertical gain is offered, each with the outstanding
accuracy and repeata bility that comes from a fully digital design.
Analog Video
For a qualitative view of the content, a full-color picture display is offered,
which can be d
compatible with PAL and NTSC inputs with format auto-sensing.
Multiformat Support
isplayed as a full-screen presentation. This display is
Timing and Synchronization Made Easy
The patented Tektronix Timing display makes facility timing easy through
a simple graphical rep resentation which shows the relative timing of the
input signa
numeric readouts of the timing difference relative to the reference, showing
vertical timing as number of lines and h orizontal differences in μs.
The SCH Phase display helps quickly verify this critical timing parameter
of composite analog video signals.
The 1741C provides VITC or LTC Time Code decode and display plus LTC
waveform display for longitudinal time code amplitude and synchronization
monitoring.
l and the reference signal on an X-Y axis. The display also has
www.tektronix.com 3
Data Sheet
Characteristics
Composite Video Interface
Characteristic
InputsFour
Input Type
Input Dynamic Range±6 dB
Maximum Operating
Amplitude
Absolute Maximum Input
Voltage
DC Input Impedance20 kΩ, nominal
Return Loss>40 dB to 6 MHz, power on
Crosstalk Between
Channels
Loopthrough Isolation>70 dB to 6 MHz
DC Offset with Restore
Off
Attenuation
Lock Range±50 ppm remains locked
External Reference
Characteristics
Input Type
DC Input Impedance20 kΩ, nominal
Return Loss>40 dB to 6 MHz, >35 dB to 30 MHz
Description
Passive loopthrough BNC, 75 Ω compensated
-1.8 V to +2.2 V, DC + peak AC
-6.0 V to +6.
>40dBto10MHz(typical)
>46dBto6MHz(typical)
35 dB, power off (standard amplitude video)
>60dBto6MHz
<7 mV (typical)
DC Restore 50 Hz and 60 Hz
Fast Mode >95% attenuation
Slow Mode <10% attenuation, <10% peaking
Slow Mode typical peaking 8% at 50 Hz and 60 Hz
Description
Passive loopthrough BNC, 75 Ω compensated
0 V, DC + peak AC
User Interface
1024 (H) × 768 (V
) pixels LCD with FlexVu and backlit buttons.
Analog Composite Waveform Vertical Characteristics
Characteristics
Vertical Measurement
Accuracy
Gain
Frequency Response
Description
±1% all gain settings
X1, X2, X5, and X10
Flat to 5.75
MHz, ±1%
Waveform Horizontal Sweep Characteristics
Characteristic
Sweep Timing Accuracy±0.5%, all rates, fully digital system
Sweep Linearity0.2% of time displayed on-screen, fully digital system
Power
100 to 240 VAC ±10%, 50/60 Hz.
Description
Physical Characteristics
Dimension
Height133.45.25
Width215.98.5
Depth(fronttoback
including handles and
BNCs)
Weightkglb.
Net3.16.8
mm
460.418.125
in.
4 www.tektronix.com
Analog Dual-Standard Waveform Mo nitor — 1741C
Ordering Information
1741C
4-input Multifunction Waveform Monitor for Analog Component and Composite
PAL/NTSC Dual Standard with Vector, SCH, Picture, and other advanced video
monitoring functions. The unit provides an integrated XGA Monitor with FlexVu user
interface.
Note: Please specify power option when ordering.
Power Options
Option
AC-DC Power Adapter
A0North America
A1
A2United Kingdom
A3Australia
A5
A6Japan
A10
A11India
Other
A99
Cabinet and Rackmount Accessories
Accesso
ry
WFM7F02
WFM7F05
WFM50F06
Description
Universal EURO
Switzerland
China
No power cord or AC adapter
tion
Descrip
Portable cabinet with handle, feet, tilt bail, and
front-panel cover
Dual rackmount for WFM6xxx/7xxx Series, 1700
Series, WFM601 Series, WFM700 Series, and audio
monitors
Filler Panel for Dual Rack Cabinet
Service Options
Option
Description
C3Calibration Service 3 Years
C5Calibration Service 5 Years
D1
D3
D5
Calibration Data Report
Calibration Report 3 Years (w/ C3)
Calibration Report 5 Years (w/ C5)
G3Complete Care 3 Years (includes loaner, scheduled
calibration and more)
G5Complete Care 5 Years (includes loaner, scheduled
calibration and more)
R3
R5
Repair Service 3 Years (including warranty)
Repair Service 5 Years (including warranty)
CA1Provides a single calibration event or coverage for the
designated calibration interval, whichever comes first
R1PW
R2PW
R3DW
Repair Service Coverage 1 Year Post Warranty
Repair Service Coverage 2 Years Post Warranty
Repair Service Coverage 3 Years (includes product
warranty period) starts at the time of customer
instrument purchase
R5DW
Repair Service Coverage 5 Years (includes product
warranty period) starts at the time of customer
instrument purchase
Product(s) are manufactured in ISO registered facilities.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix
Standard Codes and Formats.
www.tektronix.com 5
Data Sheet
6 www.tektronix.com
Analog Dual-Standard Waveform Mo nitor — 1741C
www.tektronix.com 7
Data Sheet
Contact Tektronix:
ASEAN / Australa
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Central East Eu
Mexico, Central/South America & Caribbean (52) 56 04 50 90
* European toll-free number. If not accessible, call: +41 52 675 3777
rope, Ukraine, and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Middle E as t,
Asia, and North Africa +41 52 675 3777
The Netherlands 00800 2255 4835*
People’s Rep
Republic of
United K ingdom & Ireland 00800 2255 4835*
sia (65) 6356 3900
Austria 00800 225 5 4835*
Belgium 00800 22
Brazil +55(11)37597600
Canada 1 800 833 9200
Denmark +4580881401
Finland +41526
France 00800 2255 4835*
Germany 00800 2255 4835*
Hong Kong 400 8
India 000 800 650 1835
Italy 00800 225 5 4835*
Japan 81 (3) 67
Luxembourg +41526753777
ublic of China 400 820 5835
Poland +41 52 675 3777
Korea 001 800 8255 2835
Russia & CIS +7 (495) 7484900
South Africa +41526753777
Spain 00800
Sweden 008 00 2255 4 835*
Switzerland 00800 2255 4835*
Tai wa n 886 (
55 4835*
75 3777
20 5835
14 3010
Norway 800 16098
Portugal 80 08 12370
2255 4835*
2) 2722 9622
USA 1 800 833 9200
Updated 25 May 2010
www.tektronix.com
For Further Information. Tektronix maintains a comprehensive, constantly expanding
collection of application notes, technical briefs and other resources to help engineers working
on the cutting edge of technology. Please visit www.tektronix.com