Teka CS-6000 User Manual

Assembly Instructions
and maintenance recommendations
Cooker Hoods
CS-6000Using this instruction book
Montageanleitung und Pflegehinweise
Dunstabzugshauben
CS-6000
et recommandations d’entretien
Hottes aspirantes
CS-6000
Dear Customer:
Thank you for choosing our cooker hood.
We are sure that appliance you have acquired will fully satisfy all your needs.
This model is made using top quality materials and undergoes rigorous testing throughout the manufacturing process.
Read this manual carefully before installing or using the product and faithfully follow the ins­tructions in order to guarantee optimal perfor­mance of the appliance for many years.
Keep this instruction book in a safe place so that you can consult it whenever necessary and fulfil guarantee requirements.
Before using your hood for the first time, plea­se take note of the installation and connection instructions.
Never unplug your hood by pulling the power cable, always by removing the plug from the socket.
Never switch the hood on if the electrical feed cable is in a state of disrepair or is cut, or if the appliance shows visible signs of wear on the part where the controls are found.
If the hood stops working or works abnormally, disconnect it from the mains (unplug) and inform the Technical Assistance Service.
Do not leave gas burners turned on under the hood without their being covered by a recipient such as a pot or pan.
Do not allow grease to build up on any part of the hood, especially on the filter. TO DO SO WOULD CONSTITUTE A FIRE HAZARD.
Do not flambé food underneath the hood.
Description of the appliance page 4
Special requirements before use for the first time 6
How to use the appliance 6
Motors 6 Light switches 6
Suggestions and recommendations 7
Cleaning and maintenance 8
Cleaning the filter 8
Cleaning the filter support and the hood body 8
Carbon filter 8 Grill and ventilator cleaning 9 Changing the light-bulbs 9
If something does not work 10
Technical Information 11
Installation 12
Upper Outlet 14 Re-circulation through activated carbon 14 Changing the mains cable 15
Safety instructions Índex
2 3
The hood in designed in the evacuation of gases to the outside, or for his movement thrugh carbon filter. The allow that gases can retum to the kitchen, purified.
For place the carbon filter, the anchorage of motor must coincide with the anchorage of carbon filter, and we fix in turning it in the sen­se of the hands of the clock.
Life of de carbon filter is theree to six months, depending on particuler conditions of use.
To replace old filters, we do it in reverse sense to the instalation.
5
These hoods are fitted with
A Light-switch B Sliding three-speed motor control
switch
C Operation indicator light D Controllable visor that enables better
smoke collection (gases)
E Filter body and supports F Filter support closures G Light-bulb illumination, over the coo-
king area and set behind a light diffu­ser
K Easily extractable filter fitted in the
lower part of the suction surface (optional)
H & I Anti-return fins (H), included in the
bag with the appliance documenta­tion. These are fitted a at the mouth of the outlet with their ends fitted in the holes prepared to house them (I).
J & K Grill and ventilator that can be remo-
ved for cleaning.
Description of the appliance
4
G
F
F
E
H
I
G
J
Before connecting the hood to the electricity mains, make sure that the mains voltage and frequency correspond to the values indicated on the rating plate inside the hood.
Special Requirements befo­re using for the first time
How to use the appliance
6
Suggestions and recommendations
7
Use the controls on the frontal part, switching them to the required suction speed. The hood motor has three speeds and a pilot to indicate operation of any of them:
0. Off position
1. First speed
2. Second speed
3. Third speed
This is independent of the motor. This enables the lights to be used regardless of whether the hood is in use.
Off
On
Motors
Switch on the extractor fan a few minutes before you start to cook (3 to 5 minutes) in order to ensure that a steady air flow has been establis­hed before cooking fumes appear.
Allow the extractor fan to run for several minutes after you have finis­hed cooking (3 to 5 minutes) in order to expel all the grease from the outlet duct. This prevents the return of grease, smoke and smells.
Light-switch
BIFORE CLEANING AND MAINTENANCE, BE SURE THAT THE APPLIANCE IS DISCONNEC­TED FROM THE MAINS SUPPLI.
Open the filter support by moving the
closures. Remove the support: take special care to avoid dropping it.
Remove the filter by pulling it out and pro-
ceed with cleaning, either in a dishwasher or leaving it under hot running water, clea­ning it with a non-abrasive brush.
It should be dried once cleaning is
completed.
NOTE: Cleaning in a dishwasher with strong detergents may darken the metallic surface without affecting its grease retaining perfor­mance.
WARNING: Filter cleaning should be carried out at least once a month, depending on the extent of hood use.
It should be remembered that grease accu­mulates in the hood and in the filters even though it is not switched on.
Soapy water at a temperature of about
40ºC is recommended. A damp cloth is used with this water for cleaning the hood, paying particular attention to crevices. It should then be dried using a dry cloth that does not leave any fibres.
WARNING:
Never use metallic scourers.
Do not use abrasive products that may
damage the metallic surface.
Do not scratch with hard objects such as
knives, scissors, etc.
The activated carbon filter cannot be washed or regenerated. Once it has become soiled (obstructed) it must be replaced (A).
Wait for the motor to cool before carrying out this operation.
Remove the screw that holds the grill to
the support.
Turn the grill in an anticlockwise direc-
tion.
Using a pair of pliers, situate the ventila-
tor bolt over the axle.
Clean the grill and ventilator and then dry
them.
To fit the ventilator, place the axle in the
bolt as far as it will go and then press it in.
Fit the grill by turning it clockwise.
WARNING:
The hood should never be switched on without the grill. Non-compliance with this warning shall be the sole responsibility of the user when faced with a damaged appliance.
Remove the filter support to access the
light bulbs (B).
Make sure that the hood has previously
been disconnected from the mains supply and that the bulbs to be replaced are not hot.
The maximum bulb power is 40 W.
9
Cleaning the grill and ventilator Changing the light-bulbs
Cleaning and maintenance
8
B B
Limpieza del Filtro
Cleaning the filter support
and the hood body
Carbon filter
Technical information
1110
Before calling the repairs service, make the following checks:
If something doesn’t work
Fault Possible causeSolution The hood doesn’t work
Mains cable not connected Connect mains cable
Power not reaching plug Check/repair mains supply
Hood not extracting sufficiently or vibrating
Filter saturated with grease Clean or replace filter Obstruction in venting duct Remove obstruction
Inadequate venting duct Contact installer and follow
the instructions in this manual
Lights do not work
Bulbs blown Replace bulbs
Bulbs loose Tighten up bulbs
MOD. TYP.
ELECT.
220...230 V ~ 50 Hz
190 W
Made in European Community- C.I.F.: A-39004932
CS-6000
S-622325
Nº. de fabric. Fabrík.-Nr. Serial Nº
89-555551
POTENCIA NOM. LÁMPARAS NENLEISTUNG GLÜHLAMPEN LAMPS RATE PUISSANCE LAMPES 2 X 40 W POTENCIA NOM. DAS LAMPADAS
Dimensions (mm) Voltage Frequency Maximum load
600 (900) x 500 x 150 Width x length x height SEE CHARACTERISTICS LABEL
13
Before installing the hood, consult the require­ments of the appropriate authorities concer­ning air and smoke extraction regulations.
Extracted air must not be channelled through ducts used for exhaust fumes from appliances powered by any form of energy other than elec­tricity.
The room (kitchen) must be well ventilated if the extractor hood is to be used at the same time as other extractor fans or other applian­ces powered by any form of energy other than electricity.
When the hood is to operate at the same time as other appliances powered by any form of energy other than electricity, the air output pressure must not be more than 4 Pa (4 x 10-5 bar).
To ensure optimum hood performance, the length of the venting duct should not exceed four metres and should not have more than two right angles (90º).
If the hood is supplied without a plug for mains connection (or if this is replaced), it must be disconnected from the mains by means of an omnipolar cut-off switch, with a minimum contact separation of 3 mm at all the poles, incorporated into the fixed installation.
The installation connection should be carried out using flexible wire. It must not be done using a rigid tube.
The hood should be connected to an earthed electrical installation.
The lower part of the hood should be placed at a minimum height of 60 cm above the hob for electric cookers and 70 cm for gas coo­kers.
Although it is recommended that gases be extracted to the exterior, active carbon filters may be installed. This enables the gases to return to the kitchen through the outlet.
Installation
12
h
150
500
600
530
168
530
358
440
TEMPLATE FOR ASSEMBLY UNDER FORNITURE
Upper edge of the hood lean on the wall
2 Drill hole Ø5
TEMPLATE FOR ASSEMBLY ON THE WALL
Opening for the
outlet fumes
88
150
173
98
Ø 124
Ensure that the hood is disconnected
from the mains supply.
Open the electrical connections box,
removing the screws securing its cover, and release the mains cable safety retai­ner.
Loosen the screws on the terminals mar-
ked N, L and remove the four screws which secure the intermediate unit to the chassis and guide the new cable to the drillhole in the connections box, connec­ting the blue wire to the N terminal and the brown wire to the L terminal .
If the external cable is of a diameter greater than the one supplied, entry to the connection box is achieved by pressing its side, breaking the lower thickness plastic area that has been prepared for cases like this, and cutting off any remaining burrs.
15
Replacing the mains cable
14
Extraction through the upper part (A)
Re-circulation through
active carbon
The system requires an outlet conduit.
The gas extraction lever should be set in the position <<E>> situated in the casing.
An outlet tube (non-return) is fitted, checking to ensure that the other outlets are duly cove­red.
Place the lever situated in the casing in the position <<I>>, ensuring that the round cover is placed over the opening (A).
The active carbon filter is then placed in the suction mouth.
If the kitchen is fitted with furnishings such as wall cupboards, the hood may be placed directly underneath them by using the set that is drawn on the following page. If gas extraction is required through the hood’s upper outlet (A), then a sufficiently large orifi­ce should be left for the gas outlet pipe to be fitted.
Loading...