Tecumseh HGA0470EXD User Manual

Model:HGA0470EXD
Product Description
Type: Rotary Application: CBP - Commercial Back
Pressure
Refrigerant: R22 Voltage/Frequency: 208-230V ~ 60Hz 200V ~ 50Hz
Product Specifications
Technical Data Sheet
11/30/2012
Performance
Refrigeration Capacity Input Power Efficiency
Condition Test Voltage Btu/h kcal/h W W Btu/Wh kcal/Wh W/W
ARI 230V ~ 60HZ 6995 1763 2050 925 7.56 1.91 2.22 -6.7°C (20°F) 49°C (120°F) 35°C (95°F) 4.4°C (40°F) 49°C (120°F)
EVAP TEMP COND
TEMP
AMBIENT
TEMP
RETURN
GAS
General
Evaporating Temp. Range: N/A Motor Torque: Low Start Torque (LST) Compressor Cooling: Fan
Mechanical
Weight: 25 Weight Unit of Measure: N/A Displacement (cc): 16.093 Oil Type: N/A Viscosity (cSt): N/A Oil Charge (cc): N/A Sound Power dB(A): N/A
Electrical
Voltage Range (50 Hz): 180-220 Voltage Range (60 Hz): 187-254 Locked Rotor Amps (LRA): 27.9 Rated Load Amps (RLA 50 Hz): N/A Rated Load Amps (RLA 60 Hz): 4.1 Max. Continuous Current (MCC in Amps): 8.1 Motor Resitance (Ohm) - Main: N/A Motor Resitance (Ohm) - Start: N/A Motor Type: PSC Overload Type: EXTERNAL Relay Type: N/A
LIQUID
TEMP
Agency Approval
CSA Listed, UL Recognized
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...