Tecumseh AWZ5535EXN User Manual

Performance Data Sheet
AWZ5535EXN
General Information
Model AWZ5535EXN Refrigerant R22 Test Condition ASHRAE Test Voltage 208-230V ~ 60HZ Return Gas 35°C (95°F) RETURN GAS Motor Type PSC
Performance Information
35
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h Watts 3060 3210-15 Amps 0.80 2.09
Btu/h Watts 2570 2750 2880-10 Amps 2.44 3.72 4.70
Btu/h Watts 2170 2390 2540 2650-5 Amps 3.85 5.11 6.09 6.81
Btu/h 3090 383 Watts 1850 2100 2290 2420 25300 Amps 5.05 6.29 7.27 8.01 8.52
Btu/h 9290 6680 4260 1980 Watts 1620 1900 2110 2270 24005 Amps 6.09 7.30 8.27 9.02 9.56
Btu/h 14700 12200 9830 7620 5520 3490 1490 Watts 1460 1760 2000 2180 2330 2460 261010 Amps 6.99 8.16 9.12 9.87 10.4 10.8 11.1
Btu/h 19500 17000 14800 12600 10600 8570 6600 Watts 1370 1700 1960 2160 2320 2470 262015 Amps 7.78 8.92 9.86 10.6 11.2 11.6 11.9
Btu/h 23800 21400 19200 17200 15200 13200 11200 9270 Watts 1350 1700 1980 2190 2370 2530 2690 288020 Amps 8.50 9.60 10.5 11.3 11.9 12.3 12.7 12.9
Btu/h 27800 25600 23400 21400 19400 17500 15600 13600 Watts 1390 1760 2050 2280 2480 2640 2810 300025 Amps 9.19 10.2 11.1 11.8 12.5 12.9 13.3 13.6
Btu/h 31800 29600 27500 25500 23600 21700 19800 17800 Watts 1480 1870 2180 2430 2630 2800 2970 316030 Amps 9.86 10.9 11.7 12.4 13.0 13.5 14.0 14.3
Btu/h 35800 33600 31600 29700 27800 25900 24000 22000 Watts 1630 2040 2360 2610 2820 3000 3170 3360
Amps 10.6 11.5 12.3 13.0 13.6 14.1 14.6 15.0
Btu/h 40000 38000 36000 34100 32200 30400 28500 26500 Watts 1820 2240 2580 2840 3050 3230 3410 359040 Amps 11.3 12.2 12.9 13.6 14.2 14.7 15.2 15.7
Btu/h 44700 42700 40800 38900 37100 35200 33300 31300 Watts 2060 2490 2830 3100 3320 3500 3670 385045 Amps 12.2 13.0 13.7 14.3 14.9 15.4 16.0 16.5
Btu/h 49900 48000 46100 44300 42500 40600 38700 36700 Watts 2330 2770 3120 3390 3610 3790 3960 413050 Amps 13.1 13.9 14.5 15.1 15.7 16.2 16.7 17.3
Btu/h 55900 54000 52200 50400 48600 46700 44800 42800 Watts 2630 3080 3440 3710 3930 4100 4260 442055 Amps 14.3 14.9 15.5 16.0 16.6 17.1 17.7 18.2
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 3.577057E+04 -4.975488E+03 -1.588418E+01 C2 1.085885E+03 -1.232773E+02 4.019193E-01 C3 -5.713194E+02 1.628698E+02 4.024687E-01 C4 -1.882292E+01 1.957031E+00 -2.482813E-03 C5 4.083333E+00 1.081250E+00 -3.787500E-03 C6 2.479167E+00 -1.235938E+00 -1.959375E-03 C7 2.312500E-01 -6.406250E-03 4.322917E-05 C8 -8.333333E-03 -4.375000E-03 -1.125000E-05 C9 -1.250000E-02 -2.812500E-03 1.937500E-05
C10 -5.555556E-03 3.333333E-03 2.500000E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature