Tecumseh AWZ5532EXN User Manual

Performance Data Sheet
AWZ5532EXN
General Information
Model AWZ5532EXN Refrigerant R22 Test Condition ASHRAE Test Voltage 208-230V ~ 60HZ Return Gas 35°C (95°F) RETURN GAS Motor Type PSC
Performance Information
35
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h Watts 2970 3170-15 Amps
Btu/h Watts 2410 2630 2790-10 Amps 0.01 1.04
Btu/h 2060 Watts 1950 2200 2390 2520-5 Amps 0.97 2.20 3.20 3.98
Btu/h 7040 3110 245 Watts 1590 1870 2080 2240 23600 Amps 2.84 4.02 5.00 5.78 6.36
Btu/h 11700 7630 4630 2430 775 Watts 1320 1630 1860 2040 21805 Amps 4.39 5.53 6.49 7.26 7.85
Btu/h 16100 11900 8780 6470 4690 3210 1770 Watts 1140 1470 1730 1920 2080 2220 236010 Amps 5.69 6.77 7.70 8.46 9.06 9.50 9.77
Btu/h 20300 16000 12800 10400 8510 6910 5360 Watts 1040 1390 1660 1880 2050 2200 235015 Amps 6.77 7.80 8.69 9.44 10.1 10.5 10.8
Btu/h 24400 20100 16800 14300 12300 10600 8960 7080 Watts 1010 1380 1670 1900 2090 2250 2410 259020 Amps 7.69 8.66 9.52 10.2 10.9 11.3 11.7 11.9
Btu/h 28500 24100 20800 18200 16200 14400 12700 10700 Watts 1050 1440 1750 1980 2180 2350 2520 270025 Amps 8.49 9.40 10.2 10.9 11.5 12.0 12.5 12.7
Btu/h 32600 28200 24900 22300 20200 18300 16500 14500 Watts 1160 1560 1870 2120 2330 2510 2680 286030 Amps 9.23 10.1 10.8 11.5 12.1 12.7 13.1 13.5
Btu/h 37000 32500 29200 26500 24400 22500 20700 18600 Watts 1310 1730 2050 2310 2520 2700 2870 3060
Amps 9.96 10.7 11.5 12.1 12.7 13.2 13.7 14.1
Btu/h 41500 37100 33700 31100 28900 27100 25200 23100 Watts 1520 1940 2270 2540 2750 2940 3110 329040 Amps 10.7 11.4 12.1 12.7 13.3 13.8 14.3 14.8
Btu/h 46400 42000 38600 36000 33900 32000 30100 28000 Watts 1760 2190 2530 2800 3020 3200 3370 355045 Amps 11.6 12.2 12.8 13.4 14.0 14.5 15.0 15.5
Btu/h 51600 47300 44000 41400 39300 37400 35600 33400 Watts 2040 2480 2820 3090 3310 3490 3660 383050 Amps 12.5 13.1 13.6 14.2 14.7 15.3 15.8 16.4
Btu/h 57400 53100 49800 47300 45200 43400 41600 39500 Watts 2350 2790 3130 3400 3620 3790 3960 412055 Amps 13.7 14.1 14.6 15.1 15.7 16.2 16.8 17.3
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.064637E+05 -5.709798E+03 -1.368327E+01 C2 1.128516E+03 -1.174279E+02 5.599453E-01 C3 -2.298646E+03 1.705003E+02 2.828715E-01 C4 -9.796875E+00 2.204427E+00 -5.569271E-03 C5 -1.625000E+00 8.420833E-01 -4.395833E-03 C6 1.653125E+01 -1.253646E+00 -9.322917E-04 C7 1.093750E-01 -8.718750E-03 6.552083E-05 C8 3.750000E-02 -4.208333E-03 -7.916667E-06 C9 -6.250000E-03 -1.937500E-03 2.062500E-05
C10 -4.166667E-02 3.277778E-03 -2.777778E-07
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature