Performance Data Sheet
AWJ5532EXN
General Information
Model AWJ5532EXN Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 7980 7330
Watts 1520 1510
Amps 9.08 9.04
Lb/h 107 101
Btu/h 9740 8900 8070
Watts 1610 1630 1640
Amps 9.30 9.34 9.36
Lb/h 126 119 111
Btu/h 11700 10700 9720 8700
Watts 1700 1740 1770 1800
Amps 9.53 9.63 9.72 9.81
Lb/h 149 141 132 123
Btu/h 14000 12800 11600 10400 9230
Watts 1790 1840 1890 1930 1980
Amps 9.76 9.93 10.1 10.2 10.4
Lb/h 176 166 156 146 136
Btu/h 16500 15100 13800 12400 11000
Watts 1870 1940 2000 2060 2120
Amps 10.0 10.2 10.5 10.7 10.9
Lb/h 206 195 184 173 161
Btu/h 19200 17700 16200 14600 13100 11600 10000
Watts 1950 2030 2110 2190 2270 2340 2420
Amps 10.2 10.5 10.8 11.1 11.4 11.7 11.9
Lb/h 238 227 215 203 191 178 165
Btu/h 22200 20500 18800 17100 15400 13700 12000
Watts 2030 2120 2220 2310 2400 2500 2590
Amps 10.5 10.8 11.2 11.5 11.9 12.2 12.6
Lb/h 274 262 249 237 223 210 196
Btu/h 25300 23500 21600 19800 17900 16100 14200
Watts 2100 2210 2320 2430 2540 2650 2750
Amps 10.7 11.1 11.5 12.0 12.4 12.8 13.2
Lb/h 312 299 286 273 259 245 230
Btu/h 28700 26700 24700 22700 20700 18600 16600
25
30
35
40
45
50
55
Watts 2160 2290 2420 2540 2670 2790 2910
Amps 10.9 11.4 11.9 12.4 12.9 13.4 13.8
Lb/h 352 339 325 311 297 282 267
Btu/h 32200 30100 28000 25800 23600 21500 19200
Watts 2230 2370 2510 2650 2790 2930 3070
Amps 11.1 11.7 12.3 12.8 13.4 13.9 14.5
Lb/h 394 381 367 353 338 322 306
Btu/h 36000 33700 31400 29100 26800 24500 22100
Watts 2290 2440 2600 2760 2910 3070 3220
Amps 11.4 12.0 12.6 13.3 13.9 14.5 15.1
Lb/h 438 424 410 396 381 365 349
Btu/h 39900 37500 35100 32600 30200 27700 25200
Watts 2340 2520 2690 2860 3030 3200 3370
Amps 11.6 12.3 13.0 13.7 14.4 15.0 15.7
Lb/h 484 470 456 441 426 410 393
Btu/h 44000 41500 38900 36300 33700 31100 28500
Watts 2400 2590 2770 2960 3140 3330 3520
Amps 11.8 12.6 13.3 14.1 14.8 15.6 16.3
Lb/h 531 517 503 488 473 457 440
Btu/h 48300 45600 42900 40200 37500 34700 31900
Watts 2450 2650 2850 3060 3260 3460 3660
Amps 12.0 12.8 13.7 14.5 15.3 16.1 17.0
Lb/h 579 565 551 536 521 505 488
Btu/h 52700 49900 47100 44200 41400 38500 35600
Watts 2500 2720 2930 3150 3370 3580 3800
Amps 12.2 13.1 14.0 14.9 15.8 16.7 17.6
Lb/h 628 614 601 586 571 555 538
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.339260E+04 1.400639E+03 8.406422E+00 2.502311E+02
C2 7.386995E+02 -8.335873E+00 -5.933027E-02 6.892378E+00
C3 -1.176392E+02 4.833357E+00 1.677702E-02 -9.431562E-01
C4 4.125913E+00 -6.381040E-02 -1.243432E-05 4.583090E-02
C5 -3.195693E+00 3.088140E-01 1.314422E-03 -1.311506E-02
C6 1.329913E-02 2.395816E-03 1.075564E-05 7.472897E-04
C7 -1.095566E-02 3.411987E-04 -1.077087E-06 -3.039088E-04
C8 8.069264E-03 -3.402519E-04 4.352984E-07 2.242143E-04
C9 -1.257005E-03 8.683372E-05 6.578877E-08 -3.382950E-05
C10 -1.346618E-04 -2.241853E-05 -1.046921E-07 -7.098238E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature