Performance Data Sheet
AWJ5528EXN
General Information
Model AWJ5528EXN Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 7020 6440
Watts 1310 1290
Amps 7.38 7.26
Lb/h 97.9 90.6
Btu/h 8550 7800 7050
Watts 1390 1390 1380
Amps 7.63 7.57 7.50
Lb/h 115 106 97.8
Btu/h 10300 9400 8490 7570
Watts 1460 1480 1490 1500
Amps 7.87 7.87 7.87 7.86
Lb/h 135 125 116 106
Btu/h 12300 11200 10200 9080 8000
Watts 1540 1560 1590 1620 1640
Amps 8.09 8.16 8.23 8.29 8.34
Lb/h 158 148 137 127 116
Btu/h 14500 13300 12100 10800 9580
Watts 1610 1650 1690 1730 1770
Amps 8.31 8.45 8.58 8.71 8.83
Lb/h 184 173 162 151 139
Btu/h 16900 15600 14200 12800 11400 9980 8560
Watts 1670 1730 1790 1840 1900 1950 2000
Amps 8.53 8.73 8.92 9.12 9.30 9.48 9.65
Lb/h 213 201 189 177 165 152 139
Btu/h 19600 18100 16500 15000 13400 11900 10300
Watts 1730 1810 1880 1950 2020 2090 2150
Amps 8.73 9.00 9.26 9.52 9.77 10.0 10.3
Lb/h 244 232 220 207 194 181 167
Btu/h 22400 20800 19100 17400 15700 14000 12200
Watts 1790 1880 1970 2050 2140 2220 2300
Amps 8.92 9.25 9.58 9.91 10.2 10.5 10.8
Lb/h 278 265 252 239 226 212 197

Btu/h 25500 23700 21800 20000 18100 16300 14400
25
30
35
40
45
50
55
Watts 1840 1950 2050 2150 2250 2350 2450
Amps 9.10 9.50 9.90 10.3 10.7 11.1 11.4
Lb/h 314 301 288 274 260 246 231
Btu/h 28700 26700 24800 22800 20800 18800 16800
Watts 1890 2010 2130 2250 2360 2480 2590
Amps 9.27 9.74 10.2 10.7 11.1 11.6 12.0
Lb/h 352 338 325 311 297 282 266
Btu/h 32100 30000 27900 25800 23600 21500 19300
Watts 1940 2070 2210 2340 2470 2600 2730
Amps 9.43 9.96 10.5 11.0 11.5 12.1 12.6
Lb/h 392 378 364 350 335 320 305
Btu/h 35700 33500 31200 29000 26700 24400 22100
Watts 1980 2130 2280 2430 2570 2720 2860
Amps 9.57 10.2 10.8 11.4 12.0 12.5 13.1
Lb/h 433 420 406 391 376 361 345
Btu/h 39500 37100 34700 32300 29900 27500 25100
Watts 2020 2180 2350 2510 2670 2830 2990
Amps 9.70 10.4 11.0 11.7 12.4 13.0 13.6
Lb/h 476 463 449 434 419 404 388
Btu/h 43500 40900 38400 35900 33300 30800 28200
Watts 2050 2230 2410 2590 2760 2940 3110
Amps 9.82 10.6 11.3 12.0 12.7 13.5 14.2
Lb/h 521 507 493 479 464 448 432
Btu/h 47600 44900 42300 39600 36900 34200 31500
Watts 2080 2270 2470 2660 2850 3040 3230
Amps 9.93 10.7 11.5 12.3 13.1 13.9 14.7
Lb/h 567 553 539 525 510 494 478
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.081039E+04 1.289623E+03 7.479246E+00 2.352350E+02
C2 6.685070E+02 -9.630721E+00 -5.995699E-02 5.976831E+00
C3 -1.065115E+02 2.998284E+00 7.399706E-03 -9.819755E-01
C4 3.968949E+00 -7.179902E-02 -1.828394E-04 4.520210E-02
C5 -3.018481E+00 2.949964E-01 1.301282E-03 -1.135961E-02
C6 1.043115E-02 4.039800E-03 1.464251E-05 6.808729E-04
C7 -8.234146E-03 -2.232994E-04 -7.842737E-07 -2.296606E-04
C8 6.056344E-03 6.870917E-05 1.809106E-07 1.659182E-04
C9 -9.405768E-04 2.703397E-05 1.239619E-07 -2.378310E-05
C10 -1.050039E-04 -3.774481E-05 -1.380440E-07 -6.429650E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature