Performance Data Sheet
AWH5516EXN
General Information
Model AWH5516EXN Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 4080 3430
Watts 672 656
Amps 3.04 3.03
Lb/h 52.8 46.0
Btu/h 4840 4140 3430
Watts 725 719 701
Amps 3.27 3.29 3.25
Lb/h 62.3 55.1 47.5
Btu/h 5800 5030 4240 3460
Watts 777 781 774 754
Amps 3.49 3.55 3.55 3.49
Lb/h 74.1 66.6 58.5 49.9
Btu/h 6970 6110 5240 4380 3520
Watts 826 842 846 836 814
Amps 3.71 3.81 3.85 3.83 3.74
Lb/h 88.4 80.4 71.8 62.6 52.9
Btu/h 8340 7390 6430 5460 4510
Watts 873 901 916 918 906
Amps 3.91 4.06 4.15 4.18 4.13
Lb/h 105 96.6 87.4 77.6 67.1
Btu/h 9920 8870 7800 6730 5660 4620 3600
Watts 914 957 985 998 998 983 954
Amps 4.10 4.30 4.45 4.53 4.53 4.45 4.27
Lb/h 124 115 105 94.8 83.5 71.5 58.7
Btu/h 11700 10600 9360 8170 6990 5810 4670
Watts 950 1010 1050 1080 1090 1080 1070
Amps 4.27 4.52 4.73 4.86 4.92 4.89 4.77
Lb/h 146 136 126 114 102 89.2 75.4
Btu/h 13700 12400 11100 9800 8480 7170 5880
Watts 980 1050 1110 1150 1180 1190 1180
Amps 4.40 4.72 4.99 5.18 5.30 5.34 5.27
Lb/h 170 159 148 136 123 109 94.3
Btu/h 16000 14500 13100 11600 10200 8690 7260
25
30
35
40
45
50
55
Watts 1000 1090 1160 1220 1260 1280 1290
Amps 4.51 4.89 5.22 5.49 5.67 5.77 5.77
Lb/h 196 185 173 160 146 131 115
Btu/h 18400 16900 15200 13600 12000 10400 8790
Watts 1010 1120 1210 1290 1340 1380 1400
Amps 4.57 5.03 5.43 5.77 6.02 6.19 6.26
Lb/h 225 213 200 187 172 156 139
Btu/h 21100 19400 17600 15800 14000 12200 10500
Watts 1020 1140 1250 1340 1410 1470 1500
Amps 4.59 5.13 5.60 6.02 6.35 6.59 6.73
Lb/h 256 244 230 215 200 182 164
Btu/h 24100 22100 20200 18200 16300 14300 12300
Watts 1010 1160 1280 1390 1480 1550 1600
Amps 4.55 5.18 5.74 6.23 6.64 6.96 7.18
Lb/h 290 277 262 246 230 211 192
Btu/h 27200 25100 23000 20800 18700 16500 14400
Watts 990 1160 1310 1430 1540 1630 1700
Amps 4.46 5.17 5.82 6.40 6.90 7.30 7.60
Lb/h 326 312 297 280 262 242 222
Btu/h 30600 28300 26000 23600 21300 18900 16500
Watts 956 1150 1320 1460 1590 1700 1790
Amps 4.31 5.12 5.86 6.52 7.11 7.60 8.00
Lb/h 365 350 333 316 296 276 254
Btu/h 34200 31700 29200 26600 24100 21500 18900
Watts 909 1120 1310 1480 1630 1760 1870
Amps 4.10 5.00 5.83 6.60 7.28 7.87 8.35
Lb/h 406 390 373 354 333 311 288
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.229811E+04 2.369054E+02 2.196963E+00 1.314899E+02
C2 3.766981E+02 -1.575228E+01 -3.606511E-02 3.192551E+00
C3 -3.754173E+01 1.254150E+01 1.472626E-02 -3.061254E-01
C4 5.971259E+00 -2.371469E-01 -1.030090E-03 5.530734E-02
C5 -1.354505E+00 3.828079E-01 1.045637E-03 5.690801E-03
C6 -4.985296E-01 -6.511963E-02 1.868896E-04 -2.903308E-03
C7 4.605485E-03 -1.455334E-03 -7.386604E-06 1.358607E-05
C8 -2.272901E-02 2.120743E-03 9.910673E-06 -9.107358E-05
C9 -2.298256E-03 -8.222938E-04 -8.024772E-07 -8.722108E-05
C10 1.683965E-03 5.714913E-06 -1.685717E-06 -4.201614E-08
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature