Performance Data Sheet
AEA9415EXC
General Information
Model AEA9415EXC Refrigerant R22
Test Condition ASHRAE Test Voltage 240V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type CSIR
Performance Information
Evap Temp (°F)
20
25
30
35
40
45
50
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 1940 1880 1780 1640 1480 1300 1120 934
Watts 268 263 268 280 295 310 322 327
Amps 2.04 2.04 2.06 2.09 2.12 2.15 2.18 2.21
Lb/h 23.8 24.1 23.7 22.8 21.5 19.8 17.9 15.8
Btu/h 2180 2110 2000 1850 1680 1500 1320 1140
Watts 273 270 277 290 306 320 331 334
Amps 2.07 2.08 2.09 2.12 2.15 2.19 2.22 2.26
Lb/h 26.6 26.8 26.4 25.5 24.3 22.7 21.0 19.1
Btu/h 2470 2380 2250 2090 1910 1730 1540 1360
Watts 274 275 285 299 316 330 340 341
Amps 2.09 2.10 2.12 2.14 2.18 2.22 2.26 2.31
Lb/h 29.9 30.0 29.5 28.6 27.4 25.9 24.3 22.6
Btu/h 2800 2680 2530 2360 2170 1970 1770 1590
Watts 274 278 291 307 325 340 350 350
Amps 2.11 2.11 2.13 2.17 2.21 2.26 2.31 2.36
Lb/h 33.8 33.7 33.1 32.1 30.8 29.3 27.7 26.2
Btu/h 3170 3030 2850 2650 2440 2230 2020 1830
Watts 271 280 296 315 335 351 360 360
Amps 2.11 2.12 2.15 2.19 2.23 2.29 2.35 2.42
Lb/h 38.1 37.8 37.0 35.9 34.5 33.0 31.4 29.9
Btu/h 3580 3400 3200 2970 2740 2510 2280 2080
Watts 266 280 300 323 344 362 373 372
Amps 2.11 2.13 2.16 2.20 2.26 2.33 2.40 2.48
Lb/h 42.8 42.2 41.2 39.9 38.4 36.8 35.2 33.7
Btu/h 4030 3810 3580 3320 3060 2800 2560 2340
Watts 261 280 304 330 355 375 387 387
Amps 2.10 2.12 2.16 2.22 2.28 2.36 2.45 2.55
Lb/h 48.1 47.1 45.9 44.3 42.6 40.9 39.2 37.6
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 -1.454200E+03 1.181122E+03 1.925418E+00 -2.363586E+01
C2 2.114966E+01 -1.662604E+00 4.334921E-02 1.457273E-01

C3 8.334542E+01 -2.604183E+01 -9.041833E-03 1.096454E+00
C4 1.675004E+00 -1.882779E-01 -5.215324E-04 1.999164E-02
C5 -4.190482E-01 1.457392E-01 -4.526907E-04 -4.767385E-03
C6 -7.230701E-01 2.185708E-01 1.247790E-04 -8.512139E-03
C7 -1.146892E-03 5.927406E-04 5.732437E-07 -2.165057E-05
C8 -9.146976E-03 1.041666E-03 3.586209E-06 -1.012335E-04
C9 3.186391E-03 -8.124280E-04 1.435100E-06 4.635085E-05
C10 1.612894E-03 -5.617648E-04 -3.942893E-07 1.638907E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature

Performance Data Sheet
AEA9415EXC
General Information
Model AEA9415EXC Refrigerant R22
Test Condition ASHRAE Test Voltage 240V ~ 50HZ
Return Gas 4.4°C (40°F) RETURN GAS Motor Type CSIR
Performance Information
Evap Temp (°F)
0
5
10
15
20
25
30
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 2020 1400 1050 864 759 635 395
Watts 258 241 235 238 245 256 266 274
Amps 1.78 1.90 1.96 2.00 2.03 2.08 2.18 2.34
Lb/h 26.3 18.1 13.7 11.8 10.9 9.82 7.08 1.36
Btu/h 2100 1530 1220 1070 985 873 635 176
Watts 263 249 244 248 257 268 278 285
Amps 1.82 1.93 1.98 2.01 2.03 2.07 2.16 2.31
Lb/h 27.0 19.7 16.0 14.6 14.1 13.2 10.5 4.57
Btu/h 2180 1640 1360 1220 1140 1020 764 277
Watts 266 254 253 258 268 280 291 299
Amps 1.86 1.96 2.01 2.03 2.05 2.09 2.17 2.32
Lb/h 27.8 21.1 17.9 16.8 16.4 15.4 12.4 6.10
Btu/h 2330 1810 1530 1390 1290 1140 847 311
Watts 268 259 260 268 280 294 306 314
Amps 1.89 1.99 2.04 2.06 2.08 2.12 2.20 2.35
Lb/h 29.5 23.3 20.2 19.2 18.6 17.3 13.8 6.85
Btu/h 2620 2100 1800 1630 1490 1300 949 345
Watts 269 264 269 280 294 310 324 333
Amps 1.90 2.01 2.06 2.09 2.11 2.15 2.24 2.39
Lb/h 33.1 27.0 23.9 22.6 21.7 19.8 15.6 7.70
Btu/h 3120 2570 2230 2020 1820 1560 1130 442
Watts 270 270 278 293 311 329 345 356
Amps 1.88 1.99 2.05 2.09 2.12 2.17 2.27 2.43
Lb/h 39.5 33.2 29.9 28.1 26.5 23.8 18.6 9.57
Btu/h 3880 3280 2890 2610 2340 1990 1470 667
Watts 272 277 290 309 330 352 371 384
Amps 1.82 1.94 2.02 2.06 2.11 2.17 2.28 2.46
Lb/h 49.5 42.9 39.0 36.5 34.0 30.2 23.8 13.3
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.818299E+04 1.122207E+03 -3.824076E+00 3.898204E+02
C2 -1.588895E+02 -4.927626E+00 2.752721E-02 -2.657252E+00

C3 -6.773017E+02 -2.222172E+01 1.504923E-01 -9.481487E+00
C4 2.043823E+00 -1.499330E-01 -4.925850E-04 2.314068E-02
C5 3.045756E+00 1.131224E-01 -2.642427E-04 4.964076E-02
C6 5.657389E+00 1.796795E-01 -1.320831E-03 7.972873E-02
C7 8.629772E-02 1.111146E-03 -1.443989E-05 1.197937E-03
C8 -3.966147E-02 1.103229E-03 9.028753E-06 -4.987167E-04
C9 -1.041833E-02 -4.368744E-04 1.465375E-07 -1.741142E-04
C10 -1.598040E-02 -4.616074E-04 3.942712E-06 -2.252250E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature