Hermetic Condensing Unit
Model: AE4430Y-FZ1ABA BoM: 2D411-1B R-134a 1/4 HP
Revision: A
AE4430Y-FZ1ABA 13.2 11.1 9.8 8.8 5/16” S 1/4” S N/A 212 9.5 32
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting Factory charge: 20 PSIG Nitrogen – MUST BE EVACUATED
Ambient Temperatures
Evaporator T, 80°F 90°F 100°F 110°F
°F PSIG BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T
20 18.4 1636 289 115 1512 298 123 1405 307 131 1289 316 139 25 22.1 1802 307 118 1669 316 126 1554 325 134 1438 333 142 30 26.1 1975 325 121 1835 333 129 1702 342 137 1587 351 145 35 30.4 2149 342 125 2000 351 132 1860 360 140 --- --- --­40 35.0 2331 360 128 2174 377 136 2025 386 143 --- --- --­45 40.0 2512 386 132 2347 395 139 --- --- --- --- --- --­50 45.4 2702 404 136 --- --- --- --- --- --- --- --- --­55 51.2 2893 430 140 --- --- --- --- --- --- --- --- ---
Dimensions, inches Line Connection* Pumpdown Air Oil Ch Gr. Wt.
L W H CH Suction Liquid
60 Hz Performance
Return gas temp. 65F, 5F sub cooling
90 F 90%
SCFM Oz. Lbs.
September 17, 2015
Revision: A
Specifications/ Parts:
Unit Model AE4430Y-FZ1ABA Unit Bill of Material 2D411-1B
Refrigeration Range 20 F to 55° F Fan Blade 51567 Design Pressure Low 150 Fan Shroud 70735-1 Design Pressure High 450 Fan Guard N/A Nominal Volts-Hz-Ph 220-240/50/1 Condenser 50801-6 Voltage Range 198-264 Liquid Valve N/A Min. Circuit Ampacity 2.9 Suction Valve N/A Max. Fuse Size (amps) 15 Power Cord N/A
Compressor Model AE4430Y-FZ1A Unit Drawing DGU1896-238 Comp. Bill of Material AE1232E-212-A4 Wiring Diagram 91266-01 Compressor RLA/LRA 2.1/11.5 Overload 830-10232 Replacement Kit: Relay K71-78 Relay RP4208-ZR Replacement Kit: O/L K90-103 Run Capacitor N/A Replacement Kit: St. Cap K146-32 Start Capacitor 85PS250D05
Fan Motor 810M006B56 Fan Motor RLA 0.23
Electrical Diagram