September 17, 2015
Tecumseh Products Company
Hermetic Condensing Unit
Model: AE4430Y-AA1AXG BoM: 2C401-3B R-134a 1/4 HP
Revision: A
Model
AE4430YAA1AXG
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting
Factory charge: 20 PSIG Nitrogen – MUST BE EVACUATED
Ambient Temperatures
Evaporator T, 80°F 90°F 100°F 110°F
°F PSIG BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T
20 18.4 1980 330 115 1830 340 123 1700 350 131 1560 360 139
25 22.1 2180 350 118 2020 360 126 1880 370 134 1740 380 142
30 26.1 2390 370 121 2220 380 129 2060 390 137 1920 400 145
35 30.4 2600 390 125 2420 400 132 2250 410 140 --- --- --40 35.0 2820 410 128 2630 430 136 2450 440 143 --- --- --45 40.0 3040 440 132 2840 450 139 --- --- --- --- --- --50 45.4 3270 460 136 --- --- --- --- --- --- --- --- --55 51.2 3500 490 140 --- --- --- --- --- --- --- --- ---
13.2 10.7 9.8 8.8
Dimensions, inches Line Connection* Pumpdown Air Oil Ch Gr. Wt.
L W H CH Suction Liquid
3/8” F 3/8” F N/A
60 Hz Performance
Return gas temp. 65F, 5F sub cooling
90 F 90%
SCFM Oz. Lbs.
240 9.5
33
September 17, 2015
Revision: A
Specifications/ Parts:
Unit Model AE4430Y-AA1AXG
Unit Bill of Material 2C401-3B
Refrigeration Range 20 F to 55° F Fan Blade 51567
Design Pressure Low 150 Fan Shroud 70735-1
Design Pressure High 450 Fan Guard 70846-2
Nominal Volts-Hz-Ph 115/60/1 Condenser 50801-6
Voltage Range 103-127 Liquid Valve N/A
Min. Circuit Ampacity 6.6 Suction Valve 31580-1
Max. Fuse Size (amps) 15 Power Cord 85106-19
Compressor Model AE4430Y-AA1A Unit Drawing DGU1896-240
Comp. Bill of Material AE1199E-215-J7 Wiring Diagram 91266-01
Compressor RLA/LRA 4.9/27.5
Overload 830-10043 Replacement Kit: Relay K71-35
Relay 820-10030 Replacement Kit: O/L K90-55
Run Capacitor N/A Replacement Kit: St. Cap K146-17
Start Capacitor 85PS110C76
Fan Motor 810M006C25
Fan Motor RLA 0.46
Electrical Diagram