Teco EPY4006 Reference Drawing

NAMEPLATE INFORMATION
HP KW
400 298 60
TYPICAL PERFORMANCE
0
POLE
6
FRAME
SIZE
5011B
ENCLOSURE
TEFC
CATALOG#
EPY4006
ISSUED
01/24/19
TYPE
AEHHSY
SERVICE
FACTOR
1.15
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
INS.
CLASS
F
NEMA
DESIGN
B
VOLTAGE
460HZ95
95.8
95.4
93.6
TIME
RATING
CONT.
RATED
AMBIENT
40oC
FULL LOAD
MIN. %
NOM. %
3/4 LOAD
%
EFFICIENCY
8398
INERTIA
85
81
1/2 LOAD
%
MAXIMUM
POWER FACTOR
CORRECTION
KVAR
92
POWER FACTOR
3/4 LOAD
%
1/2 LOAD
%
F. L.
%
87
MAX
ALLOWABLE
WK
2
lb-ft
2
ACCEL TIME
6.08
220
11.78
NEMA
LOAD
WK
2
Sec
MAX
ALLOWABLE
WK
2
Sec
NEMA
LOAD
WK
2
lb-ft
2
SAFE STALL
TIME IN
SECONDS
G
285
ROTOR
WR
2
lb-ft
2
TORQUE
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK DOWN
%FLT
4199852
1
COLD
100
100
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
HOT
ALLOWABLE
STARTS
PER HOUR
NEMA KVA
CODE LETTER
APPROVED:
REVISION
HOT
18
M. PRATER
DRAWING NO.
3A057EPY4006
LOCKED ROTOR
2900
CURRENTS
NO LOAD
FULL LOAD
116
449
DATE: CATALOG NO.:
T
December 2, 2005
ACROSS THE LINE CONNECTION
CONNECTION DIAGRAM
SCHEMATIC - Δ / Y CONNECTION
EPY4006
460 VOLT CONNECTION
WYE START-DELTA RUN CONNECTION
LINE LINE
460 VOLT STAR
460 VOLT RUN
DWG NO.
DAC-1545-3
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
Frames 143T - 449TZ
Loading...