Teco EPY3506 Reference Drawing

ISSUED
05/05/15
TYPE
AEHHSY
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
350 261 60
POLE
6
FRAME
SIZE
5011UZ
VOLTAGE
460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
95 95.8 95.4 93.6
EFFICIENCY
3/4 LOAD
%
1/2 LOAD
HZ
RATED
AMBIENT
40oC
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
87
NEMA
DESIGN
B
%
85 81
ENCLOSURE
TEFC
CATALOG#
EPY3506
TIME
RATING
CONT.
MAXIMUM
POWER FACTOR
CORRECTION
SERVICE
FACTOR
1.15
KVAR80
CURRENTS
NO LOAD FULL LOAD
101 393
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
1551 100 100
SAFE STALL
TIME IN
SECONDS
COLD HOT
ALLOWABLE
STARTS
PER HOUR
COLD
25 19
APPROVED: REVISION
M. PRATER
LOCKED ROTOR
BREAK
DOWN
%FLT
ROTOR
WR lb-ft
274
SOUND
PRESSURE
LEVEL @ 3 FT
HOT
DRAWING NO.
2 2
dB(A)
852 1
NEMA KVA
CODE LETTER
G
INERTIA
NEMA
LOAD
2
WK
2
lb-ft
3723 6.20220 11.97
MAX
ALLOWABLE
WK
lb-ft
2 2
ACCEL TIME
NEMA
LOAD
2
WK
Sec
ALLOWABLE
3A057EPY3506
MAX
WK
Sec
2
0
DATE: CATALOG NO.:
T
December 2, 2005
ACROSS THE LINE CONNECTION
CONNECTION DIAGRAM
SCHEMATIC - Δ / Y CONNECTION
EPY2504
460 VOLT CONNECTION
WYE START-DELTA RUN CONNECTION
LINE LINE
460 VOLT STAR
460 VOLT RUN
DWG NO.
DAC-1545-3
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
Frames 143T - 449TZ
Loading...