Taylor Freezer C712 General Manual

Item No.
C712
®
C712
Soft Serve Freezer
Twist, Pump
Offer all the popular soft serve variations from low or non­fat ice creams to custards, yogurt and sorbet. Serve two separate soft serve flavors, or an equal combination of both in a twist.
Freezing Cylinder
Two, 3.4 quart (3.2 liter).
Mix Hopper
Two, 20 quart (18.9 liter). Simplified air/mix pumps deliver the precise amount of air and mix to the freezing cylinders, and reduces operator parts. Separate hopper refrigeration (SHR) maintains mix below 41ºF (5ºC) during Auto and Standby modes.
Indicator Lights
Digital readout displays hours since last brush cleaning to assure product safety. Mix Low light alerts operator to add mix. Audible alarm may be enabled to sound when mix is low. When the Mix Out light flashes, the unit shuts down automatically to prevent damage.
Integrated Syrup Rail Option - 2 room temperature with lids & ladles, 2
heated with syrup pumps
Touch Screen Controls
Microprocessor touch controls are embedded in durable tempered glass panel. Multiple languages are selectable. Viscosity is continually measured to dispense consistent quality soft serve desserts. Temperatures in the hoppers or freezing cylinders may be displayed at any point of operation, in either Fahrenheit or Celsius. Draw counter allows operator to view number of servings dispensed.
Standby
During long no-use periods, the standby feature maintains safe product temperatures in the mix hopper and freezing cylinder.
Two Locking Casters
Front casters have a locking feature for operators to keep equipment in place. The lock can be released to move the equipment for cleaning.
Door Interlock System
Protects the operator from injury as the beater will not operate without the dispensing door in place.
Freezer Door
A specially designed thermo-plastic door allows quick ejection of product with a simple movement of the draw handle. Self closing draw handles are standard.
Rockton, Illinois 61072
800-255-0626
Phone 815-624-8333 Fax 815-624-8000
www.taylor-company.com
e-mail: info@taylor-company.com
International Office Taylor Company S.r.l. Roma, Italy Tel: +39-06-420-12002 Fax: +39-06-420-12034 e-mail: romeoff@taylor-company.com
C712 Soft Serve Freezer
39-11/16
1 (25)
(1008)
36-3/16
(919)
AIR IN (BOTH
SIDES)
28-1/4
(718)
4-3/4 (121)
9-1/4 (235)
28-9/16
(726)
52-1/2 (1334)
C712
25-7/16
(646)
OUT
22-1/2
(572)
AIR
44-1/2 (1130)
52-1/2 (1334)
57-15/16
(1472)
60
(1524)
1-3/32 (28)
EXHAUST TOWARDS FLOOR
NOTE: FIGURES IN PARENTHESES INDICATE MILLIMETERS
ELECTRICAL HOLE (2)
4-1/32
(102)
7-1/4 (184)
1-3/4 (44) ELECTRICAL HOLE
11-1/16
(281)
9-5/16
(237)
TOP VIEW - OPERATOR END
ALL CONNECTIONS LOCATED UNDERSIDE OF BASE
Weights lbs. kgs.
Net 777 352.4 Crated 855 387.8
cu. ft. cu. m.
Volume 68.4 1.94
Dimensions in. mm.
Width 25-7/16 646 Depth 36-3/16 919 Height 60 1524 Floor Clearance 4-3/4 121
*Mounted on standard casters
Electrical Maximum Minimum Poles (P) Fuse Size Circuit Ampacity Wires (W)
Left Right Left Right
208-230/60/1 Air 35 35 27 25 2P 3W 208-230/60/1 Air, Syrup 40 35 28 25 2P 3W 208-230/60/1 Water 35 35 26 25 3P 4W 208-230/60/3 Air 25 20 19 17 3P 4W 208-230/60/3 Water 25 20 18 17 3P 4W 220-240/50/1 Water 30 25 22 20 2P 3W 380-415/50/3N~ Air 12 10 11 9 4P 5W
This unit may be manufactured in other electrical characteristics. Refer to the local Taylor Distributor for availability.
(For exact electrical information, always refer to the data label of the unit.)
Bidding Specs Electrical: Volt Hz ph Neutral: Yes  No Cooling: Air Water NA
Options:
Taylor Company,
Rockton, Illinois 61072 815-624-8333 800-255-0626 Fax 815-624-8000
www.taylor-company.com
Specifications
Electrical
Two dedicated electrical connections are required. See the Electrical chart for the proper electrical requirements. Manufactured to be permanently connected. Consult your local Taylor distributor for cord & receptacle specifications as local codes allow.
Beater Motor
Two, 1.5 HP.
Refrigeration System
Two, 9,500 BTU/hr. R404A. Separate Hopper Refrigeration (SHR), One, 400 BTU/hr. R134a. (BTUs may vary depending on compressor used.)
Air Cooled
Minimum 3” (76 mm) around all sides. Install the deflector provided to prevent recirculation of warm air. Minimum air clearances must be met to assure adequate air flow for optimum performance.
Water Cooled
Water inlet and drain connections under side of base 1/2” FPT.
Options
• Cone Dispenser
• Drain Adaptor (for ease of rinsing & cleaning)
• Draw Valve Lock Kit
• Faucet
• Hopper Locks
• Hopper Agitators
• Panel Spinner
• Syrup Rail (Integrated)
• Syrup Rail Kit (side mount)
Continuing research results in steady improvements; therefore,
these specifications are subject to change without notice.
062076-ADV 11/11