Item No. _______________________________
C119
Batch Ice Cream Freezer
Features
Serve homemade, medium overrun gourmet ice cream,
custard, gelato, sorbet, Italian ice and slush. Mix and liquid
flavorings may be poured into the convenient fill chute on the
door. Fruits, candies and nuts can be folded in as product is
being drawn into your container. Manufactured in Italy by
Frigomat to ensure European equipment quality and
technology to serve gelato or medium overrun frozen
desserts.
Freezing Cylinder
One, 8.5 quart (8.0 liter).
Electronic Consistency Control
Selection on rotary switch from one to six. Automatically senses
product viscosity to control the refrigeration system for perfect ice
cream quality, batch after batch.
Variable Batch Size
Adjust to a lower viscosity setting for smaller pre-charge of mix.
Rockton, Illinois 61072
800-255-0626
Phone 815-624-8333 Fax 815-624-8000
www.taylor-company.com
e-mail: info@taylor-company.com
621
C119
International Office
Taylor Company S.r.l.
Roma, Italy
Tel: +39-06-420-12002 Fax: +39-06-420-12034
e-mail: romeoff@taylor-company.com
C119Batch Ice Cream Freezer
33
(838)
17-3/8
(440)
49-1/2
(1260)
5
(127)
NOTE: FIGURES IN PARENTHESES INDICATE MILLIMETERS.
WATER IN
WATER OUT
AUX
ELECTRICAL
CONN.
(CONNECTIONS LOCATED IN
LOWER AREA OF REAR PANEL)
22-7/8
(581)
Weights lbs. kgs.
Net 373 169
Crated 478 217
cu. ft. cu. m.
Volume 15.9 0.45
Dimensions in. mm.
Width 17-3/8 440
Water Cooled Depth 31-7/8 810
Air Cooled Depth 3331-7/8 81038
Height 49-1/2 1260
Counter Clearance:
Electrical Maximum Minimum Poles (P)
Fuse Size Circuit Ampacity Wires (W)
208-230/60/1 Air 30 24 2P 3W
208-230/60/1 Water 30 24 2P 3W
This unit may be manufactured in other electrical and cooling characteristics.
Refer to the local Taylor Distributor for availability.
(For exact electrical information, always refer to the data label of the unit.)
Bidding Specs
Electrical: Volt ___________________ Hz__________ ph _________
C119
Options:_________________________________________________
_________________________________________________________
5” (127 mm) mounted on standard casters
Neutral: Yes No Cooling: Air Water NA
Specifications
Electrical
One dedicated electrical connection is required. See the Electrical chart for
the proper electrical requirements. Manufactured to be permanently
connected. Consult your local Taylor distributor for cord & receptacle
specifications as local codes allow.
Beater Motor
One, 2 HP beater motor.
Refrigeration System
One, approximately 15,500 BTU/hr. R404A.
(BTUs may vary depending on compressor used.)
Air Cooled
Taylor Company,
A Division of Carrier Commercial Refrigeration, Inc.
Rockton, Illinois 61072
815-624-8333 800-255-0626 Fax 815-624-8000
www.taylor-company.com
Minimum 6” (152 mm) on both sides and 12” (305 mm) at rear. Minimum air
clearances must be met to assure adequate air flow for optimum
performance..
Water Cooled
Water inlet and drain connections on back panel 1/2” MPT.
Continuing research results in steady improvements; therefore, these