Taylor Freezer C001, C002 Operation Manual

Models C001 & C002
Custard Freezers
Operating Instructions
055073--M
5/28/08 (Original Publication)
(Updated 3/31/11)
Complete this page for quick reference when service is required:
Taylor Distributor:
Phone:
Fax:
E-mail:
Service:
Parts:
Date of Installation:
Information found on the data label:
Model Number:
Serial Number:
Electrical Specs: Voltage Cycle
Phase
Maximum Fuse Size: A
Minimum Wire Ampacity: A
E May, 2008 Taylor
All rights reserved. 055073-M
The word Taylor and the Crown design are registered trademarks in the United States of America and certain other countries.
Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072
Table of Contents
Section 1 To the Installer 1............................................
Installer Safety 1........................................................
Site Preparation 1.......................................................
Air Cooled Units 1.......................................................
Water Connections (Water Cooled Units Only) 2............................
Electrical Connections 2.................................................
Dasher (Beater) Rotation 3...............................................
Refrigerant 3...........................................................
Section 2 To the Operator 4...........................................
Compressor Warranty Disclaimer 4.......................................
Section 3 Safety 5....................................................
Section 4 Operator Parts Identification 8...............................
C001 Exploded View 8..................................................
C002 Exploded View 10..................................................
Dasher (Beater) and Door Assembly 12.....................................
Accessories 13..........................................................
Section 5 Important: To the Operator 14.................................
C001 14................................................................
C002 15................................................................
Symbol Definitions 16....................................................
Section 6 Operating Procedures 17.....................................
Assembly 17............................................................
Sanitizing 20............................................................
Priming for Continuous Run 21............................................
Models C001 & C002 Table of Contents
Table of Contents - Page 2
Stopping a Continuous Run for a Short Period of Time 22.....................
To Restart the Continuous Run: 22.........................................
Closing Procedure 22....................................................
Draining Product From The Freezing Cylinder 23............................
Rinsing 23..............................................................
Cleaning 24.............................................................
Disassembly 24..........................................................
Brush Cleaning 24.......................................................
Section 7 Important: Operator Checklist 26..............................
During Cleaning and Sanitizing 26.........................................
Troubleshooting Bacterial Count 26........................................
Regular Maintenance Checks 26...........................................
Winter Storage 27........................................................
Section 8 Troubleshooting Guide 28....................................
Section 9 Parts Replacement Schedule 31...............................
Section 10 Parts List 32.................................................
Wiring Diagrams 42......................................................
Note: Continuing research results in steady improvements; therefore, information in this manual is subject to change without notice.
E May, 2008 Taylor (Original Publication)
(Updated March, 2011) All rights reserved. 055073-M
The word Taylor and the Crown design are registered trademarks in the United States of America and certain other countries.
Table of Contents Models C001 & C002
Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072
Section 1 To the Installer
The following are general installation instructions. For complete installation details, please see the check out card.
Installer Safety
In all areas of the world, equipment should be installed in accordance with existing local codes. Please contact your local authorities if you have any questions.
Care should be taken to ensure that all basic safety practices are followed during the installation and servicing activities related to the installation and service of Taylor equipment.
S Only authorized Taylor service personnel
should perform installation and repairs on the equipment.
S Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the applicable code of the local area for the industry standards on lockout/tagout procedures before beginning any installation or repairs.
S Authorized service personnel must ensure
that the proper PPE is available and worn when required during installation and service.
S Authorized service personnel must remove
all metal jewelry, rings, and watches before working on electrical equipment.
Site Preparation
Review the area where the unit will be installed before uncrating the unit. Make sure all possible hazards to the user or equipment have been addressed.
For Indoor Use Only: This unit is designed to operate indoors, under normal ambient temperatures of 70_-75_F(21_-24_C). The freezer has successfully performed in high ambient temperatures of 104_(40_C) at reduced capacities.
This unit must NOT be installed in an area where a water jet or hose can be used. NEVER use a water jet or hose to rinse or clean the unit. Failure to follow this instruction may result in electrocution.
This unit must be installed on a level surface to avoid the hazard of tipping. Extreme care should be taken in moving this equipment for any reason. Two or more persons are required to safely move this unit. Failure to comply may result in personal injury or equipment damage.
Uncrate the unit and inspect it for damage. Report any damage to your Taylor Distributor.
This piece of equipment is made in the USA and has USA sizes of hardware. All metric conversions are approximate and vary in size.
The main power supply(s) to the freezer must be disconnected prior to performing any repairs. Failure to follow this instruction may result in personal injury or death from electrical shock or hazardous moving parts as well as poor performance or damage to the equipment.
Note:Allrepairsmustbeperformedbyan authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Models C001 & C002 To the Installer
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of clearance around all sides of the freezer. Install the deflector provided to prevent recirculation of warm air. Failure to allow adequate clearance can reduce the refrigeration capacity of the freezer and possibly cause permanent damage to the compressors.
081208
1
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided with a hand shut--off valve. On the underside rear of the base pan, two 1/2” (13 mm) I.P.S. water connections for inlet and outlet have been provided for easy hook--up. 1/2” (13 mm) inside diameter water lines should be connected to the unit. (Flexible lines are recommended, if local codes permit.) Depending on local water conditions, it may be advisable to install a water strainer to prevent foreign substances from clogging the automatic water valve. There will be only one water “in” and one water “out” connection. DO NOT install a hand shut--off valve on the water “out” line! Water should always flow in this order: first, through the automatic water valve; second, through the condenser; and third, through the outlet fitting to an
opentrapdrain.
A back flow prevention device is required on the incoming water connection side. Please
refer to the applicable National, State, and local codes for determining the proper configuration.
Electrical Connections
In the United States, this equipment is intended to be installed in accordance with the National Electrical Code (NEC), ANSI/NFPA 70--1987. The purpose of the NEC code is the practical safeguarding of persons and property from hazards arising from the use of electricity. This code contains provisions considered necessary for safety. Compliance therewith and proper maintenance will result in an installation essentially free from hazard!
In all other areas of the world, equipment should be installed in accordance with the existing local codes. Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each freezer requires two dedicated electrical connections. Check the data label(s) on the freezer for branch circuit overcurrent protection or fuse, circuit ampacity and electrical specifications. Refer to the
wiring diagram provided inside of the electrical box, for proper power connections.
CAUTION: THIS EQUIPMENT MUST BE PROPERLY GROUNDED! FAILURE TO DO SO CAN RESULT IN SEVERE PERSONAL INJURY FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential grounding lug that is to be properly attached to the rear of the frame by the authorized installer. The installation location is marked by the equipotential bonding symbol (5021 of IEC 60417-1) on both the removable panel and the equipment’s frame.
S Stationary appliances which are not
equipped with a power cord and a plug or another device to disconnect the appliance from the power source must have an all-pole disconnecting device with a contact gap of at least 3 mm installed in the external installation.
S Appliances that are permanently connected
to fixed wiring and for which leakage currents may exceed 10 mA, particularly when disconnected or not used for long periods, or during initial installation, shall have protective devices such as a GFI, to protect against the leakage of current, installed by the authorized personnel to the local codes.
S Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (Code designation 60245 IEC 57) installed with the proper cord anchorage to relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
080912
2
Models C001 & C002To the Installer
Dasher (Beater) Rotation
Dasher rotation must be clockwise as viewed looking into the freezing cylinder. As a safety feature, the dasher will not operate without the freezer door in place.
Note: The following procedures must be performed by an authorized Taylor service technician.
To correct the rotation on a three--phase unit, interchange any two incoming power supply lines at freezer main terminal block only.
To correct rotation on a single--phase unit, change the leads inside the dasher motor. (Follow the diagram printedonthemotor.)
Electrical connections are made directly to the terminal block. The terminal block is provided in the control box located behind the lower front panel.
Refrigerant
Refrigerant liquid sprayed onto the skin may cause serious damage to tissue. Keep eyes and skin protected. If refrigerant burns should occur, flush immediately with cold water. If burns are severe, apply ice packs and contact a physician immediately.
Taylor reminds technicians to be cautious of government laws regarding refrigerant recovery, recycling, and reclaiming systems. If you have any questions regarding these laws, please contact the factory Service Department.
WARNING: R404A refrigerant used in conjunction with polyolester oils is extremely moisture absorbent. When opening a refrigeration system, the maximum time the system is open must not exceed 15 minutes. Cap all open tubing to prevent humid air or water from being absorbed by the oil.
In consideration of our environment, Taylor proudly uses only earth friendly HFC refrigerants. The HFC refrigerant used in this unit is R404A. This refrigerant is generally considered non-toxic and non-flammable, with an Ozone Depleting Potential (ODP) of zero (0).
However, any gas under pressure is potentially hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid. Filling the cylinder to approximately 80% will allow for normal expansion.
080912
Models C001 & C002 To the Installer
3
Section 2 To the Operator
The freezer you have purchased has been carefully engineered and manufactured to give you dependable operation. The Taylor freezer, when properly operated and cared for, will produce a consistent quality product. Like all mechanical products, this machine will require cleaning and maintenance. A minimum amount of care and attention is necessary if the operating procedures outlined in this manual are followed closely.
This Operator’s Manual should be read before operating or performing any maintenance on your equipment.
Your Taylor freezer will NOT eventually compensate and correct for any errors during the set--up or filling operations. Thus, the initial assembly and priming procedures are of extreme importance. It is strongly recommended that all personnel responsible for the equipment’s operation review these procedures in order to be properly trained and to make sure that there is no confusion.
In the event that you should require technical assistance, please contact your local authorized Taylor Distributor.
Note: Warranty is valid only if the parts are authorized Taylor parts, purchased from an authorized Taylor Distributor, and the required service work is provided by an authorized Taylor service technician. Taylor reserves the right to deny warranty claims on equipment or parts if non--approved parts or refrigerant were installed in the machine, system modifications were performed beyond factory recommendations, or it is determined that the failure was caused by neglect or abuse.
Note: Constant research results in steady improvements; therefore, information in this manual is subject to change without notice.
If the crossed out wheeled bin symbol is affixed to this product, it signifies that this product is compliant with the EU Directive as well as other similar legislation in effect after August 13, 2005. Therefore, it must be collected separately after its use is completed, and cannot be disposed as unsorted municipal waste.
The user is responsible for returning the product to the appropriate collection facility, as specified by the local code.
For additional information regarding applicable local laws, please contact the municipal facility and/or local distributor.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this machine are warranted for the term indicated on the warranty card accompanying this machine. However, due to the Montreal Protocol and the U.S. Clean Air Act Amendments of 1990, many new refrigerants are being tested and developed, thus seeking their way into the service industry. Some of these new refrigerants are being advertised as drop--in replacements for numerous applications. It should be noted that, in the event of ordinary service to this machine’s refrigeration system, only the refrigerant specified on the affixed data label should be used. The unauthorized use of alternate refrigerants will void your compressor warranty. It will be the owner’s responsibility to make this fact known to any technician he employs.
It should also be noted that Taylor does not warrant the refrigerant used in its equipment. For example, if the refrigerant is lost during the course of ordinary service to this machine, Taylor has no obligation to either supply or provide its replacement either at billable or unbillable terms. Taylor does have the obligation to recommend a suitable replacement if the original refrigerant is banned, obsoleted, or no longer available during the five year warranty of the compressor.
The Taylor Company will continue to monitor the industry and test new alternates as they are being developed. Should a new alternate prove, through our testing, that it would be accepted as a drop--in replacement, then the above disclaimer would become null and void. To find out the current status of an alternate refrigerant as it relates to your compressor warranty, call the local Taylor Distributor or the Taylor Factory. Be prepared to provide the Model/Serial Number of the unit in question.
080912
4
Models C001 & C002To the Operator
Section 3 Safety
We, at Taylor Company, are concerned about the safety of the operator when he or she comes in contact with the freezer and its parts. Taylor has gone to extreme efforts to design and manufacture built--in safety features to protect both you and the service technician. As an example, warning labels have been attached to the freezer to further point out safety precautions to the operator.
IMPORTANT -- Failure to adhere to the following safety precautions may result in severe personal injury or death. Failure to comply with these warnings may damage the machine and its components. Component damage will result in part replacement expense and service repair expense.
DO NOT operate the freezer without reading
this Operator Manual. Failure to follow this instruction may result in equipment damage, poor freezer performance, health hazards, or personal injury.
Per IEC 60335--1 and its part 2 standards, “This appliance is to be used only by trained personnel. It is not intended for use by children or people with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless given supervision or instruction concerning the use of the appliance by a person responsible for their safety.”
This unit is provided with an equipotential grounding lug that is to be properly attached to the rear of the frame by the authorized installer. The installation location is marked by the equipotential bonding symbol (5021 of IEC 60417-1) on both the removable panel and the equipment’s frame.
DO NOT use a water jet to clean or rinse the freezer. Failure to follow these instructions may result in serious electrical shock.
S DO NOT operate the freezer unless it is
properly grounded.
S DO NOT operate the freezer with larger
fuses than specified on the freezer data label.
S All repairs must be performed by an
authorized Taylor service technician. The main power supplies to the machine must be disconnected prior to performing any repairs.
S Cord Connected Units: Only Taylor
authorized service technicians may install a plug on this unit.
S Stationary appliances which are not
equipped with a power cord and a plug or another device to disconnect the appliance from the power source must have an all-pole disconnecting device with a contact gap of at least 3 mm installed in the external installation.
S Appliances that are permanently connected
to fixed wiring and for which leakage currents may exceed 10 mA, particularly when disconnected or not used for long periods, or during initial installation, shall have protective devices such as a GFI, to protect against the leakage of current, installed by the authorized personnel to the local codes.
S Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (Code designation 60245 IEC 57) installed with the proper cord anchorage to relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
Failure to follow these instructions may result in electrocution. Contact your local authorized Taylor Distributor for service.
110209
Models C001 & C002 Safety
5
S DO NOT allow untrained personnel to
operate this machine.
S DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
S DO NOT remove the door, dasher, scraper
blades, or drive shaft unless the power
switch is in the OFF position. Failure to follow these instructions may result in
contaminated product or severe personal injury to fingers or hands from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S DO NOT put objects or fingers in the door
opening. This may contaminate the product
and cause severe personal injury from blade
contact.
S USE EXTREME CAUTION when removing
the dasher assembly. The scraper blades
are very sharp and may cause injury.
Cleaning and sanitizing schedules are governed by your state or local regulatory agencies and must be followed accordingly. Please refer to the cleaning section of this manual for the proper procedure to clean this unit.
DO NOT obstruct air intake and discharge openings: 3” (76 mm) minimum air space on all sides. Install the deflector provided to prevent recirculation of warm air. Failure to follow this instruction may cause poor freezer performance and damage to the machine.
For Indoor Use Only: This unit is designed to operate indoors, under normal ambient temperatures of 70_ - 75_F(21_ -24_C). The freezer has successfully performed in high ambient temperatures of 104_(40_C) at reduced capacities.
NOISE LEVEL: Airborne noise emission does not exceed 78 dB(A) when measured at a distance of 1.0 meter from the surface of the machine and at a height of 1.6 meters from the floor.
This freezer must be placed on a level surface. Failure to comply may result in personal injury or equipment damage.
080912
6
Models C001 & C002Safety
Notes:
Models C001 & C002 Safety
7
Section 4 Operator Parts Identification
C001 Exploded View
110304
Figure 1
8
Models C001 & C002Operator Parts Identification
C001 Exploded View Parts Identification
ITEM
1 PAN-DRIP 11-5/8 LONG 027503
2 GASKET-HOPPER COVER 055356
3 COVER-HOPPER-LARGE 054732
4 COVER-HOPPER-SMALL 054733
5 BUSHING-COVER-HOPPER 054734
6 CONTROL A.-FLOW REG. X59788
6a KNOB-INNER-REG. TUBE 059785
6b O-RING-12.42 MM ID X 1.4 MM 062451
6c PIN-QUICK RELEASE 3/16 X 1 S 027813
6d TUBE-INNER-REGULATOR 059787
6e REGULATOR A.-FLOW OUTER 059784
7 TRIM-REAR CORNER L. 067971
8 PANEL-REAR 066551
9 TRIM-REAR CORNER R. 067972
10 FILTER-AIR-18.00LX13.50HX.70 052779-3
DESCRIPTION PART NO.
ITEM DESCRIPTION PART NO.
11 SCREW-1/4-20X3/8 SLTD RND 011694
12 ADAPTOR A.-CASTER X18915
13 PANEL-SIDE-RIGHT * A/C 067968
14 NUT-10-32 WHIZ FLANGE
LOCKNUT
15 DEFLECTOR-BLOWER
EXHAUST
16 CASTER-4” SWV 5/8 STEM W/
BRAKE
17 PANEL-LOWER FRONT 066544
18 PANEL-SIDE-LEFT *A/C 067967
19 BUMPER 054487
20 CHUTE-CUSTARD-LONG 054633
21 PANEL A.-FRONT X66542-27
22 STUD-FREEZER 034035
020983
047912
034081
Models C001 & C002 Operator Parts Identification
9
C002 Exploded View
Figure 2
10
Models C001 & C002Operator Parts Identification
C002 Exploded View Parts Identification
ITEM
1 PANEL-SIDE TOP 029978
2 COVER-HOPPER-LARGE 054732
3 COVER-HOPPER-SMALL 054733
4 TRIM-REAR CORNER LEFT 054458
5 CONTROL A.-FLOW REG. X59788
5a KNOB-INNER REG. TUBE 059785
5b O-RING-12.42 ID X 1.4 W 062451
5c PIN-QUICK RELEASE 3/16 X 1 027813
5d TUBE-INNER REGULATOR 059787
5e REGULATOR A.-FLOW-OUTER 059784
6 PANEL-REAR 053782
7 PANEL-UPPER SIDE RIGHT 054449
8 PAN-DRIP 11-5/8 LONG 027503
9 TRIM-REAR CORNER RIGHT 054459
10 PANEL A.-SIDE RIGHT X66497
11 NUT-10-32 WHIZ FLANGE
LOCKNUT
DESCRIPTION PART NO.
020983
ITEM DESCRIPTION PART NO.
12 DEFLECTOR-BLOWER
EXHAUST
13 CASTER-4” SWV 5/8 STEM W/
BRAKE
14 ADAPTOR·A.-CASTER X18915
15 PANEL-FRONT-LOWER 066507
16 PANEL A.-SIDE LEFT X66496
17 BUMPER-FRONT 054487
*18 PANEL A.-FRONT-COMPLETE X66509-27
19 STUD-FREEZER 034035
20 PANEL-UPPER SIDE LEFT 054448
21 CHUTE-CUSTARD-LONG 054633
22 GASKET-HOPPER COVER 055356
23 FILTER-AIR 18 L X 13.5 H .70W 052779-3
24 BUSHING-COVER-HOPPER 054734
*PANEL A.-UPPER FRONT (PANEL ONLY) = X66493
047912
034081
080610
Models C001 & C002 Operator Parts Identification
11
Loading...