(Updated November, 2010)
All rights reserved.
028752--M
The word Taylor and the Crown design
are registered trademarks in the United States
of America and certain other countries.
Table of ContentsModels 8752, 8756, & 8757
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072
Section 1To the Installer
The following are general installation instructions. For
complete installation details, please see the check out
card.
Installer Safety
In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
SOnly authorized Taylor service personnel
should perform installation and repairs on
the equipment.
SAuthorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
SAuthorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and
service.
SAuthorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
Site Preparation
Review the area the unit is to be installed in before
uncrating the unit making sure that all possible
hazards the user or equipment may come into have
been addressed.
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer and 12” (305
mm) on top to allow for adequate air flow across the
condenser(s). Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezer and
possibly cause permanent damage to the compressor.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70_-75_F(21_-24_C). The freezer has successfully
performedinhighambienttemperaturesof
104_(40_C) at reduced capacities.
This unit must NOT be installed in an area
where a water jet or hose can be used. NEVER use a
water jet or hose to rinse or clean the unit. Failure to
follow this instruction may result in electrocution.
The main power supply(s) to the freezer must
be disconnected prior to performing any repairs.
Failure to follow this instruction may result in personal
injury or death from electrical shock or hazardous
moving parts as well as poor performance or damage
to the equipment.
Note:Allrepairsmustbeperformedbyan
authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Models 8752, 8756, 8757To the Installer
to avoid the hazard of tipping. Extreme care should be
taken in moving this equipment for any reason. Two or
more persons are required to safely move this unit.
Failure to comply may result in personal injury or
equipment damage.
Uncrate the unit and inspect it for damage. Report any
damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
1
This unit must be installed on a level surface
081208
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided with
a hand shut--off valve. On the underside rear of the
base pan, two 3/8” I.P.S. (for single--head units) or two
1/2” I.P.S. (for double--head units) water connections
for inlet and outlet have been provided for easy
hook--up. 1/2” inside diameter water lines should be
connected to the machine. (Flexible lines are
recommended, if local codes permit.) Depending on
local water conditions, it may be advisable to install a
water strainer to prevent foreign substances from
clogging the automatic water valve. There will be only
one water “in” and one water “out” connection for both
single--head and double--head units. DO NOT install a
hand shut--off valve on the water “out” line! Water
should always flow in this order: first, through the
automaticwatervalve;second,throughthe
condenser; and third, through the outlet fitting to an
opentrapdrain.
A back flow prevention device is required
on the incoming water connection side. Please
refer to the applicable National, State, and local codes
for determining the proper configuration.
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the freezer
for branch circuit overcurrent protection or fuse, circuit
ampacity and other electrical specifications. Refer to
the wiring diagram provided inside of the electrical box,
for proper power connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
DO NOT operate this freezer with larger fuses
than specified on the unit data label. Failure to follow
this instruction may result in electrocution or damage
to the machine.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipments frame.
Electrical Connections
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA70-1987. The purpose of the
NEC code is the practical safeguarding of persons and
property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. In all other areas of the world,
equipment should be installed in accordance with the
existing local codes. Please contact your local
authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Stationary appliances which are not equipped
with a power cord and a plug or another device to
disconnect the appliance from the power source must
have an all-pole disconnecting device with a contact
gap of at least 3mm installed in the external
installation.
Appliances that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected or not
used for long periods, or during initial installation, shall
have protective devices such as a GFI, to protect
against the leakage of current, installed by the
authorized personnel to the local codes.
101122
2
Models 8752, 8756, 8757To th e Installer
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than
ordinary polychloroprene or other equivalent synthetic
elastomer-sheathed cord (Code designation 60245
IEC 57) installed with the proper cord anchorage to
relieve conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: Thefollowing procedures shouldbe
performed by a trained service technician.
To correct the rotation on a three--phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single--phase unit, change the
leads inside the beater motor. (Follow the diagram
printedonthemotor.)
Refrigerant
In consideration of our environment, Taylor
proudly uses only earth friendly HFC refrigerants. The
HFC refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and
non-flammable, with an Ozone Depleting Potential
(ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylorreminds technicians to becautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
Electrical connections are made directly to the
terminal block provided in the splice box which is
mounted on the base pan on the right side of the
freezer for the Model 8752 and located in the splice
boxes which are mounted mid--level on the frame
channel on the right and left sides for the Models 8756
and 8757.
WARNING:R404Arefrigerantusedin
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
080815
Models 8752, 8756, 8757To the Installer
3
Section 2To the Operator
The freezer you have purchased has been carefully
engineered and manufactured to give you dependable
operation. The Taylor Models 8752, 8756, and 8757
are highly sophisticated pieces of equipment, and
when properly operated and cared for, will produce a
consistent quality product. Like all mechanical
products, they will require cleaning and maintenance.
A minimum amount of care and attention is necessary
if the operating procedures outlined in this manual are
followed closely.
This Operator’s Manual should be read before
operating or performing any maintenance on your
equipment.
Your freezer will NOT eventually compensate and
correct for any errors during the set--up or filling
operations. Thus, the initial assembly and priming
procedures are of extreme importance. It is strongly
recommended that all personnel responsible for the
equipment’soperationstudytheseprocedures
together in order to be properly trained and to make
sure that no misunderstandings exist.
In the event you should require technical assistance,
please contact your local authorized Taylor Distributor.
Note: Warranty is valid only if the parts are authorized
Taylor parts, purchased from an authorized Taylor
Distributor, and the required service work is provided
by an authorized Taylor service technician. Taylor
reserves the right to deny warranty claims on
equipment or parts if non--approved parts or
refrigerant were installed in the machine, system
modificationswereperformedbeyondfactory
recommendations, or it is determined that the failure
was caused by neglect or abuse.
Note: Constantresearchresultsinsteady
improvements; therefore, information in this
manual is subject to change without notice.
If the crossed out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive as well as other similar
legislation in effect after August 13, 2005. Therefore,
it must be collected separately after its use is
completed, and cannot be disposed as unsorted
municipal waste.
The user is responsible for returning the product to the
appropriate collection facility, as specified by your local
code.
For additional information regarding applicable local
laws, please contact the municipal facility and/or local
distributor.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this machine are
warranted for the term indicated on the warranty card
accompanying this machine. However, due to the
Montreal Protocol and the U.S. Clean Air Act
Amendments of 1990, many new refrigerants are
being tested and developed, thus seeking their way
into the service industry. Some of these new
refrigerantsarebeingadvertisedasdrop--in
replacements for numerous applications. It should be
noted that, in the event of ordinary service to this
machine’s refrigeration system, only the refrigerantspecified on the affixed data label should be used.
The unauthorized use of alternate refrigerants will void
your compressor warranty. It will be the owner’s
responsibility to make this fact known to any technician
he employs.
It should also be noted that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service
to this machine, Taylor has no obligation to either
supply or provide its replacement either at billable or
unbillable terms. Taylor does have the obligation to
recommend a suitable replacement if the original
refrigerant is banned, obsoleted, or no longer available
during the five year warranty of the compressor.
The Taylor Company will continue to monitor the
industry and test new alternates as they are being
developed. Should a new alternate prove, through our
testing, that it would be accepted as a drop--in
replacement, then the above disclaimer would
become null and void. To find out the current status of
an alternaterefrigerant as itrelates to your
compressor warranty, call the local Taylor Distributor
or the Taylor Factory . Be prepared to provide the
Model/Serial Number of the unit in question.
080815
4
Models 8752, 8756, 8757To th e Operator
Section 3Safety
We at Taylor Company are concerned about the safety
of the operator when he or she comes in contact with
the freezer and its parts. Taylor has gone to extreme
efforts to design and manufacture built--in safety
features to protect both you and the service technician.
As an example, warning labels have been attached to
the freezer to further point out safety precautions to the
operator.
IMPORTANT -- Failure to adhere to the
following safety precautions may result in severe
personal injury or death. Failure to comply with
these warnings may damage the machine and its
components. Component damage will result in
part replacement expense and service repair
expense.
DO NOT operate the freezer without reading
this Operator Manual. Failure to follow this instruction
may result in equipment damage, poor freezer
performance, health hazards, or personal injury.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipments frame.
DO NOT use a water jet to clean or rinse the
freezer. Failure to follow these instructions may result
in serious electrical shock.
SDO NOT operate the freezer unless it is
properly grounded.
SDO NOT operate the freezer with larger
fuses than specified on the freezer data
label.
SDO NOT attempt any repairs unless the
main power supply to the freezer has been
disconnected.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.
080820
Models 8752, 8756, 8757Safety
5
SDO NOT allow untrained personnel to
operate this machine.
SDO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
SDO NOT remove any internal operating
parts (example: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in severe
personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
SDO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
SUSE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer and 12” (305
mm) on top to allow for adequate air flow across the
condenser(s). Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezer and
possibly cause permanent damage to the compressor.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of 70_ -
75_F(21_ -24_C). The freezer has successfully
performedinhighambienttemperaturesof
104_(40_C) at reduced capacities.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.
080826
6
Models 8752, 8756, 8757Safety
Section 4Operator Parts Identification
Model 8752
Models 8752, 8756, 8757Operator Parts Identification
7
8752 Parts Identification
ItemDescriptionPart No.
1Panel A.--FrontX22997
2Stud-- Nose Cone022822
3Bolt-- Carriage012347
4Panel A.--Lower Side (R & L)X23956
5Panel-- Upper Side Left028599
6Hood050464
7Panel-- Upper Rear022074
8Panel-- Lower Rear025128
9Panel-- Upper Side Right028600
10Pan--Drip 11 --5/8” Long027503
11Caster--Swivel 3/4--10, 3” Wheel021279
12Gasket--Cabinet Mix Door020134
13Probe A.--MixX35981
14Boot--Mix Cover037200
ItemDescriptionPart No.
15Tank--Mix020275
16Cover A.-- Mix TankX38726
17Funnel-- Mix036637
18Tray--Drip 16--7/8 x 5--1/8020157
19Shield--Splash 23” Long022765
20Cover--Mix Storage--Center
Single
21Trim--Rear Corner022071
22Trim A.-- Upper Side Left/RightX22423
23Trim A.-- ShelfX20426
24Trim--Front--Left024824 --SP
25Trim--Front--Right024825
26Trim--Bottom Mix Door024974
27Trim--Mix Door024976
038827
8
Models 8752, 8756, 8757Operator Parts Identification
8752 Beater Door Assembly
Models 8752, 8756, 8757Operator Parts Identification
9
8752 Beater Door Parts Identification
ItemDescriptionPart No.
1Seal-- Drive Shaft032560
2Shaft--Beater032564
3Beater A.-- 3.4 Qt. 1 PinX46231
4Clip--Scraper Blade046236
5Blade-- Scraper--Plastic046235
*6aBearing--Front050348
*6bShoe-- Front Helix--Front050347
*6cShoe-- Front Helix--Rear050346
7Gasket-- Door HT 4” Double048926
8Door A.--1 Spout Long BaffleX51531--10
9Handle A.--Draw--Adj.X26996
9aDraw Handle --Adj.028804
ItemDescriptionPart No.
9bScrew--Adjustment026592
9cO--Ring (Adj. Screw)015872
9dNut--Jam 5/16--24029639--BLK
10O--Ring -- 5/16 OD x .070 W016272
11Pin A.--PivotX22820
12Nut-- Stud021508
13Val ve A .- -Dr awX18303
14O-- Ring -- 7/8 OD x .103 W014402
15Cap--Design -- 1.010” ID014218
16Plug-- Prime028805
17O-- Ring -- 3/8 OD x .070 W016137
*Order as X50350 only.
10
Models 8752, 8756, 8757Operator Parts Identification
Model 8756
Models 8752, 8756, 8757Operator Parts Identification
11
8756 Parts Identification
ItemDescriptionPart No.
1Panel A.--FrontX22879
2Stud-- Nose Cone022822
3Bolt-- Carriage012347
4Panel A.--Lower Side (R & L)X23956
5Panel-- Upper Side Left028599
6Hood048526
7Panel-- Upper Rear022015
8Panel-- Lower Rear023598
9Panel-- Upper Side Right028600
10Pan-- Drip 17--1/4” Long027504
11Caster--Swivel 3/4--10, 3” Wheel021279
12Gasket--Cabinet Mix Door024629
13Probe A.--Mix (2)X35981
14Boot--Mix Cover037200
15Tank A.-- Mix w/DecalsX38755
ItemDescriptionPart No.
15aTank (only)034928
16Cover--Mix Tank024590
17Funnel--Mix036637
18Tray-- Drip 22--7/8 x 5-- 1/8014533
19Shield--Splash 23” Long022766
20Cover--Left Mix Storage037138
21Cover--Right Mix Storage037139
22Tr im-- Corner--Left/Right022013
23Trim A.--Side Left/RightX22424
24Trim A.-- ShelfX24813
25Trim--Front--Left024824--SP
26Trim--Front--Right024825
27Trim--Bottom Cabinet024826
28Strip-- Top Trim024827
12
Models 8752, 8756, 8757Operator Parts Identification
Model 8757
Models 8752, 8756, 8757Operator Parts Identification
13
8757 Parts Identification
ItemDescriptionPart No.
1Panel A.-- FrontX36711
2Stud--Nose Cone022822
3Bolt--Carriage 1/4--20 x 3/4012347
4Panel A.-- Lower Side--L/RX36741
5Panel--Upper Side Left028599
6Hood048526
7Panel--Upper Rear042068
8Panel--Lower Rear042067
9Panel--Upper Side Right028600
10Pan-- Drip036232
11Caster--Swivel 3/4-- 10 ST021279
12Gasket--Cabinet--Mix Door024629
13Probe A.-- MixX35981
14Boot--Mix Cover037200
15Tank--MixX38755
ItemDescriptionPart No.
15aTank (only)034928
16Cover--Mix Tank024590
17Funnel--Mix036637
18Tray-- Drip014533
19Shield--Splash 23” Long022766
20Cover--Mix Storage Left037138
21Cover--Mix Storage Right037139
22Trim--Rear Corner-- Left/Right036740
23Trim A.-- Side Left/RightX22424
24Trim A.--ShelfX36732
25Trim-- Front-- Left024824--SP
26Trim-- Front--Right024825
27Trim-- Bottom Cabinet024826
28Strip--Top Trim024827
14
Models 8752, 8756, 8757Operator Parts Identification
8756 & 8757 Beater Door Assembly
ItemDescriptionPart No.
1Seal-- Drive Shaft032560
2Shaft--Beater032564
3Beater A.-- 3.4 Qt. 1 PinX46231
4Clip--Scraper Blade046236
5Blade-- Scraper--Plastic046235
*6aBearing--Front050348
*6bShoe-- Front Helix--Rear050346
*6cShoe-- Front Helix--Front050347
7Gasket-- Door 4” Double048926
8Door A.--3 Spout Long BaffleX51532--12
9Handle A.--Draw--Adj.X33687
9aDraw Handle --Adj.028804
9bScrew--Adjustment033662
Models 8752, 8756, 8757Operator Parts Identification
ItemDescriptionPart No.
9cO--Ring (Adj. Screw)015872
9dNut--Jam 5/16--24029639--BLK
10O--Ring -- 5/16 OD x .070 W016272
11Rod A.--PivotX22387
12Nut-- Stud (Long)034382
13Val ve A .- -Dr aw (3)X18303
14O-- Ring -- 7/8 OD x .103 W (6)014402
15Cap--Design -- 1.010” ID014218
16Nut--Stud (Short)034383
17Rod A.--PivotX22388
18Plug-- Prime (2)028805
19O-- Ring -- 3/8 OD x .070 W (4)016137
*Order Kit X50350
15
Accessories
L
U
B
E
04
82
60
3
10
0
4
8
2
6
0
1
2
9
11
4
5
6
ItemDescriptionPart No.
1Brush-- Mix Pump Body023316
2Brush--Pressure Switch027647
3Brush--Feed Tube021101
4Brush--Double Ended013072
5Brush--Rear Bearing013071
6Brush--Draw Valve013073
7Lubricant-- Taylor 4 oz.047518
SS
TERAHEEN
GREEN LABEL
SANITIZER & CLEANER
(MILKSTONE REMOVER)
KAY-5
Sanitizer/Cleaner
CAUTION
FORINSTITUTIONAL USE ONLY
1OZ(28.4g)
®
8
R
7
KEEPOUT OF REACH OF CHILDREN
ItemDescriptionPart No.
8Sanitizer--Kay --5 (8752, 8757)041082
9Pail--Mix 10 Qt.013163
Kit A.-- Tune Up (Model 8752)X49463--15
10
Kit A.--Tune Up
(Models 8756 & 8757)
11Sanitizer-- Stera Sheen --Green
X49463--2
065293
(8756)
071017
16
Models 8752, 8756, 8757Operator Parts Identification
Section 5Important: To the Operator
Model 8752
Model 8756
Model 8757
Models 8752, 8756, 8757Important: To the Operator
17
Loading...
+ 49 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.