Taylor Freezer 152 General Manual

Item No.
152
Soft Serve Freezer
Single Flavor, Taylormate
Features
Offer all the popular soft serve variations from low or non-fat ice creams to custards, yogurt and sorbet.
Freezing Cylinder
One, 1.5 quart (1.4 liter).
Mix Hopper
One, 8 quart (7.6 liter). Separate hopper refrigeration (SHR) maintains mix below 41ºF (5ºC) in Auto and Standby modes.
Indicator Lights
The Mix Low light alerts the operator to add mix.
Solid State Controls
Taylor Quality Control (TQC) precisely monitors viscosity to maintain consistent quality.
®
152
Standby
During long no-use periods, the standby feature maintains safe product temperatures in the mix hopper and freezing cylinder.
Rockton, Illinois 61072
800-255-0626
Phone 815-624-8333 Fax 815-624-8000
www.taylor-company.com
e-mail: info@taylor-company.com
International Office Taylor Company S.r.l. Roma, Italy Tel: +39-06-420-12002 Fax: +39-06-420-12034 e-mail: romeoff@taylor-company.com
152 Soft Serve Freezer
152
Weights lbs. kgs.
Net 212 96.2 Crated 243 110.2 cu. ft. cu. m. Volume 21.1 0.60
Dimensions in. mm.
Width 17-7/16 441.9 Depth 27-11/16 702.0 Height 30 711.2 Counter Clearance 3-15/16 101.0
*Mounted on standard legs
Electrical Total Supplied Amps with NEMACord
115/60/1 Air 16.0 5-20P 208-230/60/1 Air 10.2 6-15P 220-240/50/1 Air 7.8 ----
This unit may be manufactured in other electrical characteristics. Refer to the local Taylor Distributor for availability.
(For exact electrical information, always refer to the data label of the unit.)
Bidding Specs Electrical: Volt Hz ph Neutral: Yes  No Cooling: Air Water NA
Specifications
Electrical
One dedicated electrical connection is required. See the Electrical chart for the proper electrical requirements. Manufactured to be cord connected. Consult the international Taylor distributor for cord & receptacle specifications for 50 Hz. equipment.
Beater Motor
One, 0.5 HP
Refrigeration System
One, 3,000 BTU/hr. R404A. Separate Hopper Refrigeration (SHR), One, 400 BTU/hr. R134a. (BTUs may vary depending on compressor used.)
Air Cooled
Minimum 6” (152 mm) on both sides. Install the skirt provided on the right side of the unit and place the back of the unit against a wall to prevent recirculation of warm air. Minimum air clearances must be met to assure adequate air flow for optimum performance.
Options
• Cone Dispenser
Options:
Continuing research results in steady improvements; therefore,
these specifications are subject to change without notice.
Taylor Company,
Rockton, Illinois 61072 815-624-8333 800-255-0626 Fax 815-624-8000
www.taylor-company.com
026195-ADV 11/11