Item No. _______________________________
104
Batch Ice Cream Freezer
Features
Serve homemade, low or medium overrun ice cream, gelato,
sorbet or Italian ice. Fruits, candies and nuts can be folded
in as product is being drawn into your container. Product
may be ejected at temperatures low enough for serving,
depending on mix formulation, flavorings and overrun
desired.
Freezing Cylinder
One, 3 quart (2.9 liter). Pre-charge of liquid mix determines
overrun.
Automatic Timer Control
Finished product quality is automatically controlled by setting the
time required for the recipe. A buzzer will sound to remind the
operator to eject the finished product.
Funnel
Liquid mix and flavorings are poured into the top, using the
convenient funnel provided.
Rockton, Illinois 61072
800-255-0626
Phone 815-624-8333 Fax 815-624-8000
www.taylor-company.com
e-mail: info@taylor-company.com
104
International Office
Taylor Company S.r.l.
Roma, Italy
Tel: +39-06-420-12002 Fax: +39-06-420-12034
e-mail: romeoff@taylor-company.com
104Batch Ice Cream Freezer
Weights lbs. kgs.
Net 165 74.9
Crated 199 90.3
cu. ft. cu. m.
Volume 17.3 0.49
Dimensions in. mm.
Width 16-7/16 418
Depth 26-13/16 681
Height 21-3/8 542
Counter Clearance --- ---
*Designed to rest on a plastic pad directly on counter top.
Electrical Maximum Minimum Poles (P)
Fuse Size Circuit Ampacity Wires (W)
115/60/1 Air 35 29 2P 3W
208-230/60/1 Air 15 15 2P 3W
220-240/50/1 Air 15 12 2P 3W
This unit may be manufactured in other electrical characteristics. Refer to the
local Taylor Distributor for availability.
(For exact electrical information, always refer to the data label of the unit.)
Specifications
Electrical
One dedicated electrical connection is required. See the Electrical chart for
the proper electrical requirements. Manufactured to be permanently
connected. Consult your local Taylor distributor for cord & receptacle
specifications as local codes allow.
Beater Motor
One, 1.0 HP.
Refrigeration System
One, approximately 2,500 BTU/hr. R404A.
(BTUs may vary depending on compressor used.)
Air Cooled
Minimum clearance: 6” (152 mm) around all sides. Minimum air clearances
must be met to assure adequate air flow for optimum performance.
Bidding Specs
Electrical: Volt ___________________ Hz__________ ph _________
104
Options:_________________________________________________
_________________________________________________________
Neutral: Yes No Cooling: Air Water NA
Continuing research results in steady improvements; therefore, these
specifications are subject to change without notice.
Taylor Company,
A Division of Carrier Commercial Refrigeration, Inc.
Rockton, Illinois 61072
815-624-8333 800-255-0626 Fax 815-624-8000
www.taylor-company.com
Printed in U.S.A.
051275-ADV
3/05