Tayama TC-168 User Manual

Page 1

TAYAMATM

HUARUN APPLIANCE (USA), INC.
2660 River A ve. Rosemead,CA 91770
TOLL FREE :1-866-9TAYAMA (1-866-982-9262)
Tel: 626-280-6679 Fax: 626-280-8589
email:info@huarun.us
www .tayama-usa.com
www.tayama.us
AIR COOLER Instruction Manual
Please read this instructions carefully befor e using this product

MODEL NO.: TC-168

Page 2
CONTENTS
1.PRODUCT INTRODUCTION AND FEATURES
1. PRODUCT INTRODUCTION AND FEATURES⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅1
2. TECHNICAL PARAMETER⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅1
3. CONTROL PANEL AND CONSTRUCTION DIAGRAM⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅2
4. ASSEMBLY AND USING METHOD⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅------------------4
5. CAUTIONS ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅--------------------------------------4
6. MAINTENANCE AND CLEANING⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅5
The air cooler is a newly developed product made by our company using micro-computer as a controller. Using the theory of absorbing heat through water vaporizing and ice melting, it can reach the aim of lower temperature, freshing air and humidifying air. Meantime, we adopt filter and water curtain on it to prevent from dust and bad smell effectively. In other words, this air cooler is a good helper to make you live in comfortable and healthy environment.
Features:
1. High-grade computer-control system.
2. Mechanical and remote cont rol on opti on.
3. Cool fan, humidifier, air filter ex ist in the product in all.
4. Filter and water curtain double-pr otection, makes the air scent mor e fr esh.
5. Supply moisture to environment in dry seasons.
6. Energy saving and effective, input power of cooler is 60W.
7. 0.5-7.5 hours timer control, nine kinds of air speed on option.
8. Ice stored in water tank, ai r blows cool.
2.TECHNICAL PARAMETER
Rating voltage frequency 120VAC 60Hz. Input power 60W Max air volume > 20m³/min. Speed type 9 Kinds N.W 6 kg Dimension 300 x 397 x 650 (mm)
1
Page 3
3. CONTROL PANEL AND CONSTRUCTION DIAGRAM
2. Control panel, functions (same with remote contr oller)Fig2
1. Construction diagram:
1. Control panel
2. Louver
3. Water level indicator
4. Castor (4pcs)
5. Water box
6. Cord wire
7. Water filling box (for add water and ice)
8. Back cover
9. Air filter
10. Filter cover
11. Water drain plug
12. Handle
Fig1(Construction diagram)
ON/OFF
COOL
TIMER
SPEED
Sleep Natural
F
l
o
w
Normal
M
o
de
Fig2(Control panel)
High Mid Low
Speed
0.5 1 2 4
r
e
im
T
o
C
ON/OFF
l
o
FLOW
MODE
A. ON/OFF:
Press the button. Light on, air cooler begins to operate. Meantime, w ind speed ( high ) switch on , air cooler works on a condition of high wind speed, push again. Power off, air cooler stops working. B. Flow:
Press once, indicating light on, air cooler begins to swing horizontally and blow cool air. Push again, light off, air cooler stops sw in ging and blowing air. Meantime, if you push the louver vertically by hand, air co oler can change to blow co ol air v ertically. C. Speed:
Press once; choose wind speed from “High-Medium-Low” in turn, relative indicating lights on. Sleep wind is also divided into thr ee grades: H igh Medium-Low . D. Timer:
Press once, time is added 0.5hr till 7.5hrs. If 0.5hr and 1.0hr lights on at the same ti me, it means 1. 5hrs. If no, it means air cooler wo rks without time limit. E. Cool:
Press once, indicating light on, air cooler begins to blow air, humidify air. Press again, air cooler wor ks on a normal condition.
Remarks: whenever you switch on the machine, it will start from the initial situation. (Step1)
F. Mode:
Three types of airflow under computer control can be selected to meet your need. Press once, normal light on. Push again, nature light on. Push again, sleep light on. Same, choose wind speed from “High-Medium-Low”.
2
Remarks: Whenever you switch on the machine, it will start from the initial situation.
3
Page 4
4. ASSEMBL Y AND USING METHOD
1. Open the carton box, take out the air cooler, check whether all accessories are there or not.
2. Air cooler should be assembled horizontally. Do not incline when using. Please check power before using whether it’ s in conformit y with the label statement.
3. Add water: A new air cooler or an air cooler which has been stopped working for a
long time should be filled with clean fresh water. Take off the water box cover; add water into the box stating, “Water only “. Never add water into the box stating, “Ice only”, and please check the water level indicator when filling. No more water than line “Full”. If you need extremely cool, add ice into the box stating “Ice only”, and the water level should not be too high. (About 2/3 is enough) when water level goes near to the line “Fill”, Please add water immediately, otherwise, cooling and humidifying functions will be affected.
4. Choose different functions on the control panel (or remote controller) according to
your requirements, such as “Cool”, “Timer”, or “Speed.” (details refer to function keys introduction).
5. Press “ON/OFF” switch when you want to turn off the air cooler.

5. CAUTIONS

1. Air cooler must be disconnect ed before fill ing water.
2. Please check water drain plug set before filling water. No filling can be over the “Full”
line.
3. No incline or collide when m oving after water is filled.
4. Keep the back of air cooler 0.3m away from wall when operat ing.
5. Cool should be carefully chosen wh en envir onment moisture is t oo high.
6. Nothing can be put on the air cooler .
7. Please replace water mor e often during hot summer to keep the water clean.
8. Please drain water completely when you stop using air cooler for a long time, then
blow it for 1-2 hours.
9. Do not block the louver when operating. Putting fingers or objects in louver is also
highly dangerous
4
6.MAINTENANCE AND CLEANING
1. After using cooler for a period of time, duct and dirt will stick on the filter, and
normal operation will be affected. So you sh ould clean the filter.
(1) Filter cleaning procedure: Hold the top of filter co ver and draw out lightly. Take
out filter, clean it with weak soap water. Assemble it again when it’s dry. (wash once every 1-2 months)
(2) Water curtain cleaning procedure: take off the back lightly, take off working
shaft, and take out water curtain, wash it with soap water. Reassemble it after cleaning. Cleaning once every 6-12 months is recommended.
2. Cleaning water box is also needed when cleaning water curtain. Get rid of the dirt
and sediment in the box with soft detergent and cloth.
3. Do not dip in water or show er when cleaning the outside cover. Use warm soap water
and cloth.
4. When the remote-controller is not used for a long time, please take out the battery for
safety sake. When air cooler won’t be used for a long time, please drain out the water in box and blow air for 1-2 hours. When the water curtain is completely dry, you can put it in a box and store it in a dr y place for later use.
5