The Tannoy CMS801 subwoofer is a compact unit is specifically designed to complement
the full range CMS ceiling monitor systems; delivering low frequency extension into
applications that require a combination of premium sonic quality and output level for music
and speech reinforcement.
The 200mm (8.00") driver, with long throw multi fibre paper pulp cone, and a 2nd order
160Hz passive crossover are mounted in a vented, injection moulded, paintable front baffle
manufactured from UV/weather resistant UL94V-0 ABS material.
Two CMS801 subwoofer model versions and a separate back can are available to satisfy
the vast majority of installation application requirements:
CMS801 sub BM (Blind Mount) - supplied with an integral back can.
CMS801 sub PI (Pre-Install) - supplied without a back can.
CMS801 PI Back Can (Pre-Install back can) - use with the CMS801 sub PI.
The CMS801 sub BM model is equipped with a low insertion loss 60W line transformer
mounted within the back can. This is easily configurable to the following settings via front
baffle mounted rotary tapping switch:
The CMS801 sub PI is supplied without a transformer. If the product is to be used without a
back can a 60W line transformer (7600 1658) is available as an optional accessory for easy
connection to the baffle mounted control switch circuit. Installing the transformer in this
manner (flying) requires installation in accordance with local building regulations.
NOTE: For optimum performance and full compliance with safety ratings Tannoy
recommends using the CMS801 PI back can (8001 4570) accessory option in which the
transformer is pre-fitted.
The zinc plated steel back cans have an integrated, recessed termination box. The
removable locking connector has screw terminals for secure wire termination and "loop
through" facility. Strain relief is provided by a clamping mechanism for use with plenum
rated cable or conduit.
Features
• High Power & high sensitivity with low distortion
• UV/weather resistant UL94V-0 ABS front baffle
• Blind Mount & Pre Install options
• Easily accessible tapping switch on front baffle
• Low insertion loss 60W line transformer
• Packaged with tile rails and C-ring for quick &
easy installation and simple stocking logistics
• Five year warranty
Applications
• Multizone foreground music and paging systems
• Boardrooms and offices
• Business music systems
• Airports, convention centres, hotels
• Reception and waiting rooms
• Houses of worship
• Retail outlets and shopping malls
• Lounges and bars
• Cruise ships
• Courtrooms
Spring loaded self-aligning clamps make for quick and easy installation, while all models
are also supplied with two tile support rails and one C-ring included in the package.
A plaster (mud) ring is available as an optional accessory.
Tannoy United Kingdom
Tannoy North America
Tannoy Deutschland
Tannoy France
Tannoy adopts a policy of continuous improvement and product specification is subject to change
CMS801 BM / PI sub data file // issue 1.06 // 14.01.08
CMS801 sub
TECHNICAL SPECIFICATIONS
SystemCMS801 sub
1)
requency response (-3dB)
F
Frequency range (-10dB)
ystem sensitivity (1W @1m)
S
CrossoverIntegral 2nd order passive,
ated maximum SPL
R
Average112dB
Peak118dB
verage with THP60110dB
A
Power handling
(3)
Average100W
rogramme200W
P
eak400W
P
Recommended amplifier power 200W @ 8 Ohms
Nominal Impedance8 Ohms
Transformer taps
(via front rotary switch)
70V60W / 30W / 15W / 7.5W / OFF
100V60W / 30W / 15W / OFF
Distortion
10% Full Power (7.75V)2nd Harmonic3rd Harmonic
70Hz1.22%1.90%
100Hz0.38%0.49%
1% Full Power (2.45V)2nd Harmonic3rd Harmonic
70Hz0.91%1.28%
100Hz0.04%0.44%
Notes
(1)
Average over stated Bandwidth. Measured in an IEC baffle in an Anechoic Chamber
(2)
Unweighted pink noise input, measured in an IEC baffle in an Anechoic Chamber.
If the loudspeaker is placed in the ceiling near a corner ( /
in sensitivity and maximum SPL can be realised.
(3)
Long term power handling capacity as defined in EIA - 426B test
A full range of measurements, performance data, and Ease™ Data can be
downloaded from www.tannoy.com
Tannoy operates a policy of continuous research and development. The introduction
of new materials or manufacturing methods will always equal or exceed the
published specifications, which Tannoy reserves the right to alter without prior
notice. Please verify the latest specifications when dealing with critical applications.
(
8Hz - 160Hz
5
(1)
42Hz - 300Hz
(2)
2dB (1W = 2.45V for 8 Ohms)
9
60 Hz
1
(
2)
& Low Impedance operation
& Low Impedance operation
) an increase of 6dB
2
Transducer
1x 200mm (8.00") long throw woofer with
multi fibre paper pulp cone
Physical
Enclosure
Back canZinc plated steel
BaffleReflex loaded UL 94V-0 rated ABS
rilleSteel, with weather resistant coating
G
afety featuresSafety ring located at rear of enclosure
S
Clamping designSecurity toggle clamp
ack can options
B
lind Mount (BM)Complete with fixed back can
B
re Install (PI)Separate back can for Pre Installation
P
Cable entry optionsCable clamp & squeeze connector for
Conduit knockouts3 Sets of horizontal positions
ConnectorsRemovable locking connector with screw
Safety agency ratings
(pending) UL-1480, UL-2043, CE
BM Hole cutout diameter295mm (11.61")
PI Hole cutout diameter295mm (11.61")
Dimensions
Bezel diameter325mm (12.80")
Front of ceiling to
rear of back can (BM)310.5mm (12.22")
Front of ceiling to
top of safety loop (BM)327.8mm (12.90")
Front of ceiling to rear
of speaker unit (PI)117.50mm (4.63")
Front of accessory back can
bezel to top of safety loop (PI) 168.5mm (6.63")
Net weight (ea)
CMS801 sub BM6.3kg (13.89lbs)
CMS801 sub PI3.2kg (7.05lbs)
PI Back can4kg (8.81lbs)
Included accessoriesC Ring, tile bridge, paint mask,
Optional accessoriesPlaster (Mud) Ring
for load bearing safety bond
conduit up to 22mm
19 / 22 / 28mm (0.75 / 0.87 / 1.1")
terminals with "loop through" facility
cutout template, grille
Ordering information
Part numberPacked Weight
8001 4730CMS801 sub BMWhite219.0 (41.89)
8001 4740CMS801 sub PIWhite211.5 (25.35)
8001 4650Plaster Ring - CMS801N/A108.0 (17.64)
8001 4570Back can CMS801 PI 8 OhmN/A14.5 (9.92)
7600 1658CMS 60 Watt XFMR/Lead Dual 8 OhmN/A1012.0 (26.46)
Tannoy United Kingdom
Tannoy North America
Tannoy Deutschland
Tannoy France
Tannoy adopts a policy of continuous improvement and product specification is subject to change
CMS801 BM / PI sub data file // issue 1.06 // 14.01.08
CMS801 sub
The PIThe PI bback can aack can acccceepts dpts diirectrect
ccoonnectnnectiion to inston to instaalled conduit in twolled conduit in two
wawayys us ussinging
squeeze cqueeze coonnectornnectorss::
AAnnyy ofof thethe threethree kknnock-ouock-outt p pooininttss atat
he Ceiling Subwoofer System shall consist of a 200mm (8.00") transducer, with long throw multi fibre paper pulp cone, and a 2nd order 160Hz passive
T
rossover mounted in a vented, injection moulded, paintable front baffle in UL94V-0 ABS material.
c
The back can in both PI (pre-install) & BM (Blind-mount) variants shall be constructed of zinc plated steel. A recessed termination box shall be integrated with
the back can, a removable locking connector with screw terminals for secure wire termination with "loop through" facility shall be provided. Strain relief will be
provided by a clamping mechanism for use with plenum rated cable or conduit.
For pre-wiring the PI (pre-install) back can is provided with conduit knockouts (19mm/22mm/28mm, 0.75"/0.87"/1.14"). A safety ring is located on the rear of
the back can for a load bearing safety bond.
Performance of the Ceiling Subwoofer System shall meet or exceed the following criteria: Frequency range measured on axis shall be 42Hz - 300Hz (-10dB
from rated sensitivity, measured in an IEC baffle in an anechoic chamber with no equalization). Sensitivity shall be 92dB (1W @ 1m where 1W = 2.45V for 6
Ohms). Long term power handling capacity as defined in EIA-426B test shall be 100W, recommended amplifier power 200W. The nominal system
mpedance shall be 6 Ohms (in low impedance setting).
i
The Ceiling Subwoofer System shall be equipped with a 60W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 60,
30, 15, 7.5* Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance
settings. A weather resistant perforated steel grille covers the transducer and switch.
Two support rails and one C-Ring shall be included with the ceiling monitor system.
Bezel diameter 325mm (12.80")
Front of ceiling to rear of back can 310.5mm (12.22"), Front of ceiling to top of safety loop 327.8mm (12.90")
Front of ceiling to rear of speaker unit 117.50mm (4.63"), Front of accessory back can bezel to top of safety loop 168.5mm (6.63")
The Ceiling Subwoofer System shall be the.....CMS801 sub.
*70 Volt only
Tannoy United Kingdom
Tannoy North America
Tannoy Deutschland
Tannoy France
Tannoy adopts a policy of continuous improvement and product specification is subject to change