Tannoy CMS 503ICT PI, CMS 603ICT PI Quick Start Guide

CMS 3.0 SERIES
In-Ceiling loudspeakers
CMS 503ICT PI CMS 603ICT PI
Quick Start Guide
1 Introduction
This Quick Start Guide (QSG) provides the basic information required to install and connect the pre­install (PI) versions of Tannoy CMS Series in-ceiling loudspeakers.
For additional information, including product
technology, photo identication of product features,
dimensional drawings, and complete technical
specications, please refer to the full CMS Series
Operation Manual.
For installation of CMS Series blind-mount versions, please refer to either the CMS BM Quick Start Guide or the full CMS Operation Manual.
2 Safety Notices
Some regional construction codes require the use of a secondary method of securing loudspeakers in ceiling to provide security of a back-up support. A secondary support line should be attached from the safety loop on the rear of the product to a source point on the ceiling. For PI models, the secondary support line should be attached from the back of the driver chassis to a source point on the ceiling. Please consult the relevant construction codes in your region.
When using a power driver to install the product, it is essential to use the correct torque level settings to avoid over tightening and damage to the ceiling material or clamps. Recommended torque setting:
1.5 Nm Tannoy will not be held responsible for any damages caused by the improper installation of these loudspeakers.
3 Unpacking
Every Tannoy product is carefully inspected before shipment. After unpacking, please inspect your product to ensure no damage has occurred in transit. In the unlikely event of damage, please notify your dealer and retain all shipping materials as your dealer may require return shipment. All CMS loudspeakers are shipped in pairs and provided with the following accessories as standard: C-ring, tile-bridge kit, cut-out template and paint mask. A plaster (mud) ring is available as an optional accessory.
4 Installation in Suspended Ceilings
An optional pre-install backcan is available for all pre-install (PI) models. The backcan is designed for pre-installation in newly constructed, non­suspended ceilings.
NOTE: The CMS 603ICT models have the transformer pre-attached to the inside of the backcan; the CMS 503ICT models have the transformer pre-attached to the loudspeaker assembly.
1. Attach the backcan to a secure xing point.
This can be done one of three ways:
METHOD 1: Fix to a secure point using suitable xings attached to the four xing holes on the PI
backcan. (Fig.1)
Electrical Safety Notice: to comply with the
standard UL1480, metal-clad exible conduit (BX)
is required for connection to the terminal block for proper earth grounding.
SAFETY NOTE: In order to comply with the
relevant re safety regulations (i.e. BS 5839:1998), it is required that in the event of re, that failure of
the circuit to which the loudspeaker is connected does not occur before evacuation of the building is complete. Suitable measures include:
• Use of terminal blocks (for connection to primary) with a melting point of not less than
650°C, for example constructed from ceramic
materials;
• Use of terminal blocks of a lower melting point but protected with thermal insulation;
• Use of terminal blocks such that, on melting, an open-circuit or a short-circuit does not occur.
Fig.1
METHOD 2: Fix to a secure point using suitable xings and the exible straps attached to the PI
backcan. (Fig. 2)
Fig.2