TAMKO COOLRIDGE User Manual

Application Instructions for
®
COOLRIDGE
NOTICE: This product must be applied in conformance with the manufacturer’s instructions.
1.Cut a slot in plywood
along roof ridge 2" wide (1" on each side). If ridge beam is present, cut slot 1" wide on each side of ridge beam. Allow for a closed area of sheath­ing 12" at both ends of ridge.
2.Place first piece of
vent with female end 1" in from gable end and use cent ering line for proper alignment along peak. Fasten using at least two nails at each end and in the middle of s ec tion i n nail line area (2-1/2 " minimu m nail length). More may be required on steeper slopes to seat properly. Continue installing addi­tional pieces along ridge sliding female end over male end, aligning using centering line. NOTE: In cold weather, allow 1/8" gap between vent sections for expansion.
4.Place rst cap shin-
gle over vent so that it overhangs at least 1" over end of vent sec­tion. Install with 2-1/2" nails in nail line area as you work your way down the roof. Cut last cap shingle so that it overhangs vent 1" at other gable end.
HELPFUL HINTS
Optionally, you may install cap shingles on each piece as you go along, taking care to assure proper alignment.
If installing on dimensional or architectural shingles on new construc­tion, leave felt underlayment about 6" long at roof ridge and fold back under the vent so that vent is essentially installed on top of felt over the
shingles. If re-roong, caulk between low areas of shingle and bafe of
vent after installation.
Lines across top of product indicate where the end plugs are on the un-
derside (every 12"). There is no need to ip the last piece if you measure
and plan ahead to install on an even foot increment.
The nail line area is completely free from obstructions except where the end plugs are (unlike other sectional ridge vents that can have
nails deect off of supports). By using the end plug indicators on top of
product, you can easily avoid nails through the end plugs.
3.When reaching the
other end, the last vent section may need to be cut to length. End plugs are provided every 12" on underside of the prod­uct. M ea su re amount needed to install to within 1" of gable end. Cut that length in from end of vent
section and ip around
so that end plug is at gable end. Allow male tab from previous piece to slide under last piece and nail in place.
800-641-4691
Visit Our Web Site at
tamko.com
Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 10/2008 Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868