Tait TBCHHA, TBCHHB Users Manual

TB7000/TB8000/TB9000 TN9110 P25 CG TN9111 P25 TAG

Safety and Compliance Information

Informations sur la conformité et consignes de sécurité

Informações sobre segurança e conformidade

Información sobre medidas de seguridad y conformidad

产品安全与符合性信息
MBA-00012-12 · 02/2018
Contact Information
Tait Communications Corporate Head Office
Tait Limited P.O. Box 1645 Christchurch New Zealand
For the address and telephone number of regional offices, refer to our website: www.taitradio.com
Coordonnées de Tait
Tait Communications Siège social
Tait Limited P.O. Box 1645 Christchurch Nouvelle-Zélande
Pour les adresses et numéros de téléphone des branches régionales, veuillez consulter notre site Internet:
www.taitradio.com
Para contactarnos
Oficina corporativa de Tait Communications
Tait Limited P.O. Box 1645 Christchurch Nueva Zelanda
Si desea obtener una lista de direcciones y números de teléfono de las oficinas regionales, visite nuestra página web: www.taitradio.com .
公司总部
大吉有限公司 Tait Limited 邮政信箱:1645 P.O. Box 1645 基督城 Christchurch 新西兰 New Zealand
有关各大区域分支机构的地址和电话,请访问我们的 网站:www.taitradio.com
Informação para contato
Tait Communications Sede Corporativa
Tait Limited P.O. Box 1645 Christchurch Nova Zelândia
Para endereço e telefone dos escritórios regionais consulte o site www.taitradio.com.
Important: Read carefully before use. Keep for future reference.
For the latest user documentation, visit http://support.taitradio.com.
Important: Veuillez lire ces informations avec attention avant toute utilisation. Conservez-les à titre de référence.
Pour accéder aux manuels d'utilisation les plus récents, veuillez visiter http://support.taitradio.com.
Wichtig: Bitte dieses Dokoment vor der Benutzung lesen und als zukünftige Referenz aufbewaren.
Die aktuelle Benutzerdokumentation finden Sie auf http://support.taitradio.com.
Importante: Leia com atenção antes de usar. Guarde para referência futura.
Para a documentação mais recente do usuário, por favor visite http://support.taitradio.com.
Importante: Leer detenidamente antes de usar. Mantener para referencia futura.
Para ver la documentación más reciente para el usuario, visite http://support.taitradio.com.
重要:使用之前应当认真阅读。保留妥当以供日后参考。 关于最新的用户文档,请访问 http://support.taitradio.com.
2

Copyright and Trademarks

All information contained in this document is the property of Tait Limited. All rights reserved. This document may not, in whole or in part, be copied, photocopied, reproduced, translated, stored, or reduced to any electronic medium or machine-readable form, without prior written permission from Tait Limited.
The word TAIT and the TAIT logo are trademarks of Tait Limited.
All trade names referenced are the service mark, trademark or registered trademark of the respective manufacturers.

Disclaimer

There are no warranties extended or granted by this document. Tait Limited accepts no responsibility for damage arising from use of the information contained in the document or of the equipment and software it describes. It is the responsibility of the user to ensure that use of such information, equipment and software complies with the laws, rules and regulations of the applicable jurisdictions.

Enquiries and Comments

If you have any enquiries regarding this document, or any comments, suggestions and notifications of errors, please contact your regional Tait office.
English

Updates of Manual and Equipment

In the interests of improving the performance, reliability or servicing of the equipment, Tait Limited reserves the right to update the equipment or this document or both without prior notice.

Intellectual Property Rights

This product may be protected by one or more patents or designs of Tait Limited together with their international equivalents, pending patent or design applications, and registered trade marks: NZ 409837, NZ 409838, NZ 415277, NZ 415278, NZ 530819, NZ 534475, NZ 547713, NZ 577009, NZ 579051, NZ 579364, NZ 586889, NZ 610563, NZ 615954, NZ 700387, NZ 708662, NZ 710766, NZ 711325 , NZ 726313, NZ593887, AU 2015215962, AU 339127, AU 339391, AU2016259281, AU2016902579, EU 000915475-0001, EU 000915475-0002, GB 2532863, US 14/834609 Div. no 1, US 15/346518 Div.no 2, US 15/350332, US 15/ 387026 Div., US 20150085799, US 20160044572, US 20160057051, US 640974, US 640977, US 698339, US 702666, US 7758996, US 8902804, US 9107231, US 9504034, US 9559967.
Safety and Compliance Information 3
English
TB7300 and TB9300 only: This product may also be made under license under one or more of the following patents:
- US7203207, AU2004246135, CA2527142, GB2418107, HK1082608, MY134526, US8306071
- US7339917, AU2004246136, CA2526926, GB2418812, MY134217
- US7499441, AU2005262626, CA2570441, GB2430333, JP4690397, NZ551231, KR100869043, RU2351080, BRP10512052, MXPA06015241
- US 7200129, AU2005226531, CA2558551, CN1930809, GB2429378, JP4351720, BRP10508671, NZ549124, KR848483, RU2321952
TB7300, TB9100, TB9300, TB9400 and gateways only: The IMBE™ (TB9100 and gateways) and AMBE+2™ (TB7300, TB9300 and TB9400) voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding Technology is licensed solely for use within this Communications Equipment. The user of this Technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into a human-readable form.

Environmental Responsibilities

Tait Limited is an environmentally responsible company which supports waste minimization, material recovery and restrictions in the use of hazardous materials.
The European Union’s Waste Electrical and Electronic Equipment (WEEE) Directive requires that this product be disposed of separately from the general waste stream when its service life is over. For more information about how to dispose of your unwanted Tait product, visit the Tait WEEE website at www.taitradio.com/weee. Please be environmentally responsible and dispose through the original supplier, or contact Tait Limited.
Tait Limited also complies with the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Directive in the European Union.
In China, we comply with the Measures for Administration of the Pollution Control of Electronic Information Products. We will comply with environmental requirements in other markets as they are introduced.
4 Safety and Compliance Information

About this Document

This document provides general safety and regulatory information only. Please read the Installation and Operation Manual before attempting to install or operate the equipment.

General Safety

Personal Safety

English
Unpacking and Moving the Equipment (except TB7100 and TB7300)
Lethal Vol tag es
To prevent personal injury and equipment damage, we recommend that two people unpack and move the equipment.
Caution A subrack complete with modules can weigh up to 62 lb (28 kg), or up to 66 lb (30 kg) complete with packaging. We recommend that you have another person help you unpack and move the equipment. The TBAA03-16 carrying handles will make it easier to move the sub­rack once it has been unpacked. If necessary, remove the modules from the subrack before moving it (refer to the Installation and Operation Manual). In all cases follow safe lifting practices.
Warning The PMU and TB7100 optional AC power supply unit
contain voltages that may be lethal. Refer to the ratings label on the rear of the module.
Notice Before connecting to the TB7100 AC power connector, refer to the ratings label on the rear of the base station for its configured mains voltage.
The equipment must be installed so that the rear of the PMU or TB7100 is located in a service access area which is accessible only by qualified personnel. The PMU or TB7100 must be connected to the mains supply source by trained personnel in accordance with local and national regulations. The plug of the TB7100 AC power supply cord is intended as the disconnect device. Therefore, the socket-outlet must be installed near the equipment and must be readily accessible.
Disconnect the mains IEC connector and wait for five minutes for the internal voltages to self-discharge before dismantling. The AC power on/off switch does not isolate the PMU from the mains. It breaks only the phase circuit, not the neutral. Ensure that all TB7100 power sources (AC and DC) are disconnected before opening the base station.
The PMU and TB7100 AC power supply unit should be serviced only by qualified technicians. There are no user-replaceable parts inside. If the PMU or TB7100 AC power supply unit is damaged and does not function properly, stop the module safely and contact your regional Tait office immediately.
Safety and Compliance Information 5
All servicing should be carried out only when the PMU or TB7100 AC power supply unit is powered through a mains isolating transformer of sufficient rating.
English
AC Power Connection
Explosive Environ­ments
Proximity to RF Transmissions
English (en) The equipment must be connected to a grounded mains
socket-outlet.
Norsk (no) Apparatet må tilkoples jordet stikkontakt. Suomi (fi) Laite on liitettävä suojamaadoitus-koskettimilla
varustettuun pistorasiaan.
Svenska (sv) Apparaten skall anslutas till jordat uttag.
Warning Do not operate the equipment near electrical blasting
caps or in an explosive atmosphere. Operating the equipment in these environments is a definite safety hazard.
To comply with the RF Field Limits for Devices Used by the General Public for (Uncontrolled Environment) least 3.6 metres (12 feet) from the antenna system should be maintained.
This figure is calculated for a typical installation, employing one 100 W base station transmitter. Other configurations, including installations at multi-transmitter sites, must be installed so that they comply with the relevant RF exposure standards.
a. Reference Standards
Health Canada’s Safety Code 6: Limits of Human Exposure to
Radiofrequency Electromagnetic Energy in the Frequency Range from 3 kHz to 300 GHz.
USA Federal Communications Commission OET bulletin 65 (47CFR 1.1310). IEEE C95.1 2005: Standard for Safety Levels with Respect to Human
Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.
a
, a safe separation distance of at
High Temperatures
Take care when handling a PMU, PA, TB7100 or TB7300 which has been operating recently. Under extreme operating conditions (+ 140 °F [+60 °C] ambient air temperature) or high duty cycles, the external surfaces of the modules can reach temperatures of up to + 176 °F (+ 80 °C).
LED Safety (EN 60825-1)
This equipment contains Class 1 LED Products.

Equipment Safety

Installation and Servicing Personnel
Antenna Load The base station has been designed to operate safely under a wide range of
6 Safety and Compliance Information
The equipment should be installed and serviced only by qualified personnel.
antenna loading conditions. Transmitting into a low VSWR will maximise the power delivered to the antenna.
ESD Precautions
Notice Do not remove the load from the PA while it is transmitting.
Load transients (switching or removing the load) can damage the PA output stage.
Notice Before opening any module, make sure that you take proper precautions against electrostatic discharge. This equipment contains devices that are susceptible to damage from static charges. You must handle these devices carefully and according to the procedures described in the manufacturers’ data books.
We recommend you purchase an antistatic bench kit from a reputable manufacturer and install and test it according to the manufacturer’s instructions. The following diagram shows a typical antistatic bench set­up.
Typical antistatic bench set-up
English
common point ground (building ground or mains ground)
conductive wrist strap dissipative rubber
bench mat
You can obtain further information on antistatic precautions and the dangers of electrostatic discharge (ESD) from standards such as ANSI/ ESD S20.20-1999 or BS EN 100015-4 1994.

Environmental Conditions

Operating Temperature Range
Humidity The humidity should not exceed 95% relative humidity through the
Dust and Dirt For uncontrolled environments, the level of airborne particulates must not
The operating temperature range of the 40 W and 50 W TB7100 base stations is – 22°F to + 122°F (– 30°C to + 50°C) ambient temperature. The operati ng temperature range of all other equipment is – 22°F to + 140°F (– 30°C to + 60°C) ambient temperature. Ambient temperature is defined as the temperature of the air at the intake to the cooling fans.
specified operating temperature range.
exceed 100 µg/m
3
.
Safety and Compliance Information 7

Grounding and Lightning Protection

English
Electrical Ground (except TB7100 and TB7300)
The modules are grounded by physical contact between the module case and the subrack. To ensure a good ground connection you must tighten each module retaining clamp securely (refer to the section “Final Reassembly” in the Installation and Operation Manual for the correct torque setting).
A threaded grounding connector is provided on the rear of the subrack for connection to the site ground point (refer to the section on connecting the base station in the Installation and Operation Manual for more details).
Electrical Ground (TB7100 and TB7300 only)
Lightning Ground It is extremely important for the security of the site and its equipment that
A threaded grounding connector is provided on the rear of the tray for connection to the site ground point (refer to the section on connecting the base station in the Installation and Operation Manual for more details).
you take adequate precautions against lightning strike. While it is outside the scope of this manual to provide comprehensive information on this subject, we recommend that you conform to your country’s standards organization or regulatory body.

Equipment Ventilation

Always ensure there is adequate ventilation around the equipment.
Notice Do not operate it in a sealed cabinet. You must keep the ambient temperature within the specified range, and we strongly rec­ommended that you ensure that the cooling airflow is not restricted.
Notice All products except TB7100 and TB7300: Cooling fans are mounted on the front panel and will only operate when the panel is fitted correctly to the front of the subrack. To ensure ade­quate airflow through the equipment, do not operate it for more than a few minutes with the front panel removed (e.g . for servicing purposes).
Notice TB7100 and TB7300 only: Cooling fans are mounted behind the front panel. To ensure adequate airflow through the base station, do not operate it for more than a few minutes with the fans disconnected (e.g. for servicing purposes).
PMU
The only controls on the PMU are the on/off switches on the rear panel for the AC and DC modules, and the indicator LEDs visible through a slot in the front panel.
Warning These switches do not totally isolate the internal cir-
cuitry of the PMU from the AC or DC power supplies. You must disconnect the AC and DC supplies from the PMU before disman-
8 Safety and Compliance Information
tling or carrying out any maintenance. Refer to the service manual for the correct servicing procedures.
AC Module On/Off Switch
DC Module On/Off Switch
This switch turns the AC input to the PMU on and off. Note that this switch breaks only the phase circuit, not the neutral.
This switch turns the DC output from the PMU on and off. It is recessed to prevent the DC module being accidentally switched off, thus disabling the battery back-up supply.
Note that this switch does not disconnect power from the DC converter itself. It disables the converter by switching off its control circuitry. Even when the DC converter is off, the DC input is still connected to its power circuitry.

Replacing Modules

Caution The 100 W PA and PMU weigh between 9.3 lb (4.2 kg) and
15.4 lb (7 kg) each. Take care when handling these modules to avoid per­sonal injury.

Device and Network Security

If this radio network equipment is used for mission-critical applications, it is important to be able to ensure security and continuity of operation. For IP-network-connected equipment, it is also important to ensure that this equipment is not a means of compromising other equipment in the network.
All network elements should be physically secured, where possible. This includes the use of locked cabinets and locked rooms. Seals on connectors can also provide a visual indication of unauthorized tampering.
Tait recommends that all network and audio connectors should be sealed with the stick-on type of seal. The seal should reveal if any of the connectors have been unplugged, or if any unauthorized equipment has been plugged in.
English
The seals should be difficult to remove without breaking, and should bridge between the cable and equipment side (plug and socket) of the connection.
Seals should cover any unused network or audio sockets. This includes the Ethernet connector on any adaptor front panels, any spare switch ports, and the console port on the router and switch.
The seals should be difficult to reproduce. A sticker initialed or signed by the technician should satisfy this.
Seals must be replaced if they need to be disturbed during maintenance.
Safety and Compliance Information 9

Regulatory Information

English
Distress Frequencies
The 406 to 406.1 MHz frequency range is reserved worldwide for use by Distress Beacons. Do not program transmitters to operate in this frequency range.
FCC Compliance This equipment complies with:
CFR Title 47 Part 15 Class B (except PMU):
Radiated and conducted emissions, and electromagnetic susceptibil­ity specifications of the Federal Communications Commission (FCC) rules for the United States.
Operation is subject to the following two conditions: a. This device may not cause harmful interference, and b. This device must accept any interference received, including
interference that may cause undesired operation.
CFR Title 47 Part 15 Class A (PMU only):
Radiated and conducted emissions, and electromagnetic susceptibil­ity specifications of the Federal Communications Commission (FCC) rules for the United States.
Operation is subject to the following two conditions: a. This device may not cause harmful interference, and b. This device must accept any interference received, including
interference that may cause undesired operation.
CFR Title 47 Part 90 Subpart R (TB9100 only):
The use of frequencies in the 764 to 776 MHz and 794 to 806 MHz bands. The equipment can be set up to comply with the requirement of § 90.553 (a) of 47 CFR. This states that:
a. Encryption is not permitted on the nationwide Interoperability
calling channels. These channels are defined in § 90.531 (b) (1) (ii).
b. Encryption can be disabled by the user, if required.
Unauthorized Modifications
Health, Safety and Electromagnetic Compatibility in Europe
Any modifications you make to this equipment which are not authorized by Tait Limited may invalidate your approval to operate the equipment.
In the European Community, radio and telecommunications equipment is regulated by Directive 2014/53/EU. The requirements of this directive include protection of health and safety of users, as well as electromagnetic compatibility.
Intended Purpose of Product
Notice All base stations:
This product is a radio transceiver. It is intended for radio-communica­tion in the Private Mobile Radio (PMR) or Public Access Mobile Radio (PAMR) services, to be used in all member states of the European Union (EU) and states within the European Economic Area (EEA). This prod­uct can be programmed to transmit on frequencies that are not harmo-
10 Safety and Compliance Information
nized throughout the EU/EEA, and will require a licence to operate in each member state.
Notice All gateways: This product is intended for radio-communication in the Private Mobile Radio (PMR) or Public Access Mobile Radio (PAMR) services, to be
English
used in all member states of the European Union (EU) and states within the European Economic Area (EEA).
For Customers in Luxembourg (TB7100 only)
Declaration of Conformity
This equipment must not be operated as a data repeater in Luxembourg unless it is used in conjunction with an approved Channel Access Controller that meets the requirements of ETSI standard EN 300 471.
You can download the formal Declaration of Conformity from www.taitradio.com/eudoc.
Safety and Compliance Information 11
Français

Copyright et marques déposées

Toutes les informations contenues dans ce document sont la propriété de Tait Limited. Tous droits réservés. Il est interdit de copier, photocopier, reproduire, traduire, enregistrer ce manuel en tout ou en partie et de le réduire entièrement ou partiellement à un support électronique ou à une forme lisible par les ordinateurs sans l’autorisation écrite préalable de Tait Limited.
Le mot TAIT et le logo TAIT sont des marques déposées de Tait Limited.
Tous les noms de marque mentionnés correspondent aux marques de service, marques commerciales ou marques déposées des fabricants respectifs.

Clause de non responsabilité

Ce document ne comprend aucune prolongation de garantie et n’octroie aucune garantie. Tait Limited se dégage de toute responsabilité pour tout dommage découlant de l’utilisation des informations contenues dans ce document ou de l’équipement et du logiciel qui y sont décrits. Il incombe à l’utilisateur de vérifier que l’utilisation de ces informations, équipements et logiciels est conforme aux lois, réglementations et règlements des juridictions compétentes.

Questions et commentaire

Pour toute question concernant ce document ou pour tout commentaire, suggestion ou communication d’erreurs, veuillez vous adresser à votre succursale Tait régionale.

Mises à jour du manuel et de l’équipement

Dans le but d’améliorer la performance, la fiabilité et l’entretien, Tait Limited se réserve le droit de mettre à jour son équipement et/ou ce document sans notification préalable.

Droits de propriété intellectuelle

Il se peut que ce produit soit protégé par un ou plusieurs brevets ou conceptions de Tait Limited ainsi que leurs équivalents internationaux, des demandes de brevet d'invention ou de conception en cour et des marques déposées : NZ 409837, NZ 409838, NZ 415277, NZ 415278, NZ 530819, NZ 534475, NZ 547713, NZ 577009, NZ 579051, NZ 579364, NZ 586889, NZ 610563, NZ 615954, NZ 700387, NZ 708662, NZ 710766, NZ 711325 , NZ 726313, NZ593887, AU 2015215962, AU 339127, AU 339391, AU2016259281, AU2016902579, EU 000915475-0001, EU 000915475­0002, GB 2532863, US 14/834609 Div. no 1, US 15/346518 Div.no 2, US 15/350332, US 15/387026 Div., US 20150085799, US 20160044572,
12 Informations sur la conformité et consignes de sécurité
US 20160057051, US 640974, US 640977, US 698339, US 702666, US 7758996, US 8902804, US 9107231, US 9504034, US 9559967.
TB7300 et TB9300 uniquement: TB7300, Ce produit peut également être réalisé sous licence au titre de l'un ou de plusieurs des brevets suivants :
- US7203207, AU2004246135, CA2527142, GB2418107, HK1082608, MY134526, US8306071
- US7339917, AU2004246136, CA2526926, GB2418812, MY134217
- US7499441, AU2005262626, CA2570441, GB2430333, JP4690397, NZ551231, KR100869043, RU2351080, BRP10512052, MXPA06015241
- US 7200129, AU2005226531, CA2558551, CN1930809, GB2429378, JP4351720, BRP10508671, NZ549124, KR848483, RU2321952
TB7300, TB9100, TB9300, TB9400 et passerelles uniquement: La technologie de codage vocal IMBE™ (TB9100 et passerelles) et AMBE+2™ (TB7300, TB9300 et TB9400) intégrée dans ce produit est protégée par des droits de propriété intellectuelle et notamment les droits de brevet, copyrights et secrets industriels de la société Digital Voice Systems, Inc. Cette technologie de codage vocal est cédé sous licence uniquement pour être utilisé sur cet équipement de communication. Il est strictement interdit et l'utilisateur de cette technologie s'engage à respecter cette interdiction, d'essayer de décompiler, faire de l'ingénierie inverse ou désassembler le code exécutable, ou de convertir de quelque façon que ce soit le code exécutable en une forme déchiffrable.

Responsabilités en matière d'environnement

Tait Limited est une société respectueuse de l'environnement qui apporte son soutien à la minimisation des déchets et à la récupération des matériaux.
Selon la Directive de l'Union européenne relative à l'élimination des déchets d'équipements, ce produit doit être éliminé séparément et ne doit pas être jeté avec les ordures ménagères lorsqu'il arrive en fin de vie. Pour plus d'informations sur la procédure à respecter pour éliminer le produit Tait en fin de vie, rendez-vous sur le site Internet de Tait www.taitradio.com/weee. Veuillez respecter l'environnement et éliminez ce produit par l'intermédiaire de votre fournisseur ou contactez Tait Limited.
Tait Limited respecte également la Directive concernant l'utilisation limitée de certaines substances dangereuses sur les appareils électriques et électroniques (RoHS) au sein de l'Union Européenne.
En Chine, nous respectons les mesures relatives à la gestion du Contrôle de la pollution par les produits électroniques. Nous respectons également les exigences liées à l'environnement sur les différents marchés, sur lesquels nous lançons nos produits.
Français
Informations sur la conformité et consignes de sécurité 13
Français

A propos du présent document

Ce document fournit des informations générales sur la réglementation et la sécurité uniquement. Merci de lire le manuel d’installation et d'utilisation avant de commencer à installer ou utiliser l'équipement.

Sécurité générale

Sécurité des personnes

Déballer et déplacer l’équipement (sauf pour la TB7100 et la TB7300
Afin de prévenir toute blessure corporelle et d'éviter d'endommager l'équipement, nous vous recommandons d'effectuer le déballage et le déplacement de l'équipement à deux personnes.
Attention Un rack complet avec des modules peut peser jusqu’à 28 kg ou jusqu’à 30 kg avec l’emballage. Nous vous recommandons de demander à quelqu'un autre de vous aider à déballer et déplacer l’équip­ement. Les poignées TBAA03-16 permettent de déplacer plus facile­ment le rack une fois qu’il est déballé. Si nécessaire, retirez les modules du rack avant d’essayer de le déplacer (veuillez vous référer au manuel d’installation et d’utilisation). Dans tous les cas, adoptez une méthode de levage sans risque.
Haute tension ­Danger de mort
Avertissement Des tensions constituant un danger de mort
sont présentes dans l’UGA et dans l’unité d’alimentation secteur (en option) de la TB7100. Veuillez vous référer à l'étiquette des caractéristiques nominales figurant à l'arrière du module.
Avis Avant la connexion au connecteur d’alimentation secteur de la TB7100, référez- vous à l’étiquette de tension nominale à l’arrière de la station de base pour sa tension secteur configurée.
L’équipement doit être installé de telle sorte que l'arrière de l'UGA ou de la TB7100 se trouve dans une zone où seul le personnel qualifié peut en effectuer l'entretien. L'UGA ou la TB7100 doit être connectée à l'alimentation secteur par un électricien qualifié conformément à la réglementation locale et nationale. La prise du cordon d’alimentation secteur de la TB7100 permet de le déconnecter. Donc, il faut installer la prise de courant près de l’équipement et elle doit être d’un accès facile.
Débranchez le connecteur secteur CEI et attendez cinq minutes pour permettre l'autodécharge des tensions internes avant de procéder au démontage. Le commutateur de marche/arrêt CA n'isole pas l'UGA du secteur. Il coupe uniquement le circuit de phase, pas le neutre. Veillez à ce que toutes les sources d’alimentation de la TB7100 (CA et CC) soient déconnectées avant d’ouvrir la station de base.
L'entretien et les réparations de l'UGA et de l’unité d’alimentation secteur de la TB7100 doivent être effectués uniquement par des techniciens qualifiés. Elles n’ont aucune pièce qui puisse être remplacée par l'utilisateur. En cas d'endommagement ou de dysfonctionnement de l'UGA
14 Informations sur la conformité et consignes de sécurité
Connexion alimentation CA
Environnements explosifs
ou de l’unité d’alimentation secteur de la TB7100, arrêtez le module avec précaution et contactez immédiatement votre représentant Tait ou service clientèle le plus proche.
Toutes les tâches d'entretien et de réparation doivent être réalisées uniquement lorsque l'UGA ou l’unité d’alimentation secteur de la TB7100 est alimentée par un transformateur d'isolation d'une puissance suffisante.
L'équipement doit être branché à une prise secteur mise à la terre.
Avertissement Ne pas utiliser l'équipement à proximité de
détonateurs électriques ni dans une atmosphère explosive. L'utilisa­tion de l’équipement dans de tels environnements constitue un réel risque pour la sécurité.
Français
A proximité des émissions RF
Pour respecter les limites imposées au champ RF au niveau des équipements utilisés par le grand public (environnement non contrôlé)
a
une distance de séparation de sécurité d’au moins 3.6 mètres du bloc d’antenne devrait être observée.
Ce nombre est calculé pour une installation typique, ayant un émetteur de station de base de 100 W. D’autres configurations, incluant les installations ayant des sites de plusieurs émetteurs, doivent être installées de façon à se conformer aux normes pertinentes des expositions RF.
a. Normes de référence
Températures élevées
Code de sécurité 6 de Santé Canada: Limites d'exposition humaine à l’énergie électromagnétique radioélectrique dans la gamme de fréquences de 3 kHz à 300 GHz.
Commission fédérale des communications (FCC) des Etats Unis d’Amérique bulletin OET numéro 65 (47CFR 1.1310). IEEE C95.1 2005: Norme pour les niveaux de sécurité compatibles avec
l'exposition des personnes aux champs électromagnétiques de radiofréquence 3 kHz à 300 GHz.
Prendre des précautions particulières lors de la manipulation d'une UGA, d’un ampli, d’une TB7100 ou d’une TB7300 qui vient d'être utilisé. Dans des conditions extrêmes de fonctionnement (température ambiante + 60 °C [+140 °F]) ou en cas de cycles de fonctionnement élevé, les surfaces externes des modules peuvent atteindre des températures allant jusqu'à + 80 °C (+176 °F ).
Sécurité LED (EN60825-1)
Cet équipement contient des diodes electroluminescentes qui sont considérées comme des produits LED de classe 1.

Sécurité des équipements

Personnel technique
Charge d’antenne La station de base a été conçue afin de fonctionner en toute sécurité sous
L'installation et les réparations de l’équipement doivent être effectuées uniquement par des techniciens qualifiés.
une plage étendue de conditions de charge d’antenne. Le fait que la station de base transmet avec un faible VSWR (ROS Rapport d’Onde Stationnaire) augmente la puissance envoyée à l’antenne.
,
Informations sur la conformité et consignes de sécurité 15
Loading...
+ 32 hidden pages