Page 1
S-4500-TRM, S-4501-TRM, S-4502-TRM
Canterbury
Operation & Maintenance Manual
Model Numbers Specifications
™
Trim Series
S-4500-TRM Valve Trim
S-4501-TRM Shower Trim
S-4502-TRM Tub/Shower Trim
Tub/shower trim with lever handle and secondary
integral diverter includes non-diverter tub spout (069)
and 3 mode showerhead (4-163) with standard
2.5 gpm (9.5 L/min) ow restrictor. Shower trim with
lever handle and secondary integral volume control
includes all of the above less non-diverter tub spout.
Valve trim with lever handle and secondary integral
volume control includes shower escutcheon only.
Components made from metal and plastic materials
plated in standard polished chrome nish.
Modifications Compliance
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-STN Satin nickel finish
-ASME A112.18.1; CSA B125.1
Warranty
Limited Lifetime - to the original end purchaser in
consumer installations.
5 Years - for commercial installations.
Note: Append appropriate -sufx to model number.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ (800)796-6667 ■ Fax: (800)961-9621
©2014 Symmons Industries, Inc. ■ www.symmons.com ■ gethelp@symmons.com ■ ZV-3074 REV 0 06/16/2014
Refer to www.symmons.com/warranty for complete
warranty information.
Page 2
Measurements
A Ø 2 1/4", 57 mm
B
AA
D
D
B
E
E
B 8 1/2", 216 mm
C 7 1/2", 191 mm
D 77", 1956 mm
E 3 1/2", 89 mm
F Ø 2 5/8", 67 mm
32", 813 mm (S-4502-TRM)
G
H 12", 305 mm
I 2 13/16", 71 mm
J 3 1/16", 78 mm
K
45", 1143 mm (S-4501-TRM,
S-4500-TRM)
(Rough-in)
2 3/8" ± 1/2", 60 mm ± 13 mm
C
C
I
I
J
J
H
H
K
K
L 1/2" NPS
M 3/8", 10 mm
N 7 1/4", 184 mm
GG
L
F
F
Floor
Floor
L
N
N
M M
Notes:
1) All dimensions measured from nominal rough-in (see K as reference).
2) Dimensions are subject to change without notice.
2
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ (800)796-6667 ■ Fax: (800)961-9621
©2014 Symmons Industries, Inc. ■ www.symmons.com ■ gethelp@symmons.com ■ ZV-3074 REV 0 06/16/2014
Page 3
Replacement Parts
Item Description Part Number
A Showerhead 4-163
B
B
C
C
D
E
F
A
G
H
I
J
K
Shower Arm
Flange
Plug Button
Star Washer
Handle
Set Screw
Lock Nut
Dome Cover
Mounting Hardware
Shower Escutcheon
300
T-226
T-19/20-PL
T-225B
L Diverter Handle T-30C
M Tub Spout 069
Notes:
F
E
D
J
K
I
1) Append -STN to part number for Satin nickel nish.
2) Append -1.5 or -2.0 to showerhead for low ow.
H
G
Required for Installation
L
M
Adjustable wrench
Phillips head screwdriver
Teon Tape
3
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ (800)796-6667 ■ Fax: (800)961-9621
©2014 Symmons Industries, Inc. ■ www.symmons.com ■ gethelp@symmons.com ■ ZV-3074 REV 0 06/16/2014
Page 4
Note:
For valve body installation, please
see valve body installation guide.
1) Install secondary integral
2) Install shower escutcheon (K) to
diverter (L) into shower
escutcheon (K).
K
L
shower valve. Secure with two
screws (J).
K
1
J
4) Install handle (F) to valve and
secure with screw (G) and star
washer (E).
Attach plug
button (D) to handle.
F
1
E
G
D
Note: Handles should be facing the
6 o'clock position.
5)
Install tub spout (M) to pipe tting.
Turn clockwise to secure.
6) Attach shower arm (B) and
ange (C) to vertical shower pipe
turning clockwise to tighten.
1
2
C
B
7) Install showerhead
arm
(B)
turning clockwise to
(A)
to shower
tighten.
B
1
A
1
2
M
3) Install dome cover (I) to valve and
secure with lock nut (H).
I
1
H
4
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ (800)796-6667 ■ Fax: (800)961-9621
©2014 Symmons Industries, Inc. ■ www.symmons.com ■ gethelp@symmons.com ■ ZV-3074 REV 0 06/16/2014
Page 5
Care and Cleaning
1) Clean nished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse
with water.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting. Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then
quickly rinse with water.
Operation
Temperature Control
1) Turn shower handle counterclockwise approximately
1/4 turn to put valve in cold position.
2) Turn shower handle counterclockwise approximately
1/2 turn to put valve in warm position.
Diverter Control
1) Turn diverter left for tub spout operation.
2) Turn diverter right for showerhead operation.
3) Turn shower handle counterclockwise approximately
3/4 turn to put valve in hot position.
5
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ (800)796-6667 ■ Fax: (800)961-9621