Symmons S-4301 Installation Manual

Sereno
Shower System S-4301
Installation Brief
Model Number
S-4301
Shower System
Decorative Finish Code
append to part numbers if applicable
-STN
--
Satin Nickel Chrome (standard)
Rough-in Installation
Control valve, piping & fittings
Reference rough-in dimension illustration on page 2 as required.
1) Determine wall thickness
Determine type of wall and wall thickness where valve will be mounted.
■ Consider whether to use mounting plate by reviewing gure 2 below.
■ Skip ahead to Step 3 if mounting plate will not be used.
2) Attach mounting plate to valve
Seat mounting plate against valve assembly as illustrated in gure 1.
Tools & Materials
Pipe
Plumbers
Putty
Figure 1
3) Attach protective shield
■ Reference gure 2 to determine whether shield is required.
■ Attach plastic protective shield by snap tting over end of valve spindle.
Sealant
1 2 3 4
Mounting plate
Contact Symmons customer service
at (800) 796-6667, (781) 848-2250, customerservice@symmons.com Mon - Fri 7:30 am - 7:00 pm EST
Please check Symmons website
for technical help, the latest product
information and warranty policy.
www.symmons.com/service
4) Install piping, fittings and
control valve
Piping and ttings not supplied
Control Valve
Install valve through cutout hole in wall as specied in gure 2 below and dimension illustration on page 2.
Showerhead (S on valve)
Pipe from outlet port on valve marked S to showerhead mounting arm location.
Hot & Cold Supply (H & C)
Pipe hot water supply to valve input marked H and cold water supply to valve input marked C.
Walls for using T-177 mounting plate
Fiberglass or acrylic walls (required)
Plaster or other type walls (optional)
1/16" (2 mm) min 1/2" (13 mm) max
Protective shield
When mounting plate is used, then shield is optional for protecting end of valve during installation.
"snap on-off"
p/n T-176
wall cutout hole size
3-1/2" ( 95 mm) min
4" (101 mm) max
p/n T-177
nished
wall
Dry wall, plaster or other type wall
1/2" (13 mm) or greater
Ensure valve’s mounting plate is ush against inner wall
Finished wall must be ush with back side of protective shield surface
Protective shield
"snap on-off"
(required when mounting plate is not used)
wall cutout hole size
3-1/2" ( 89 mm) min
4" (101 mm) max
Figure 2 Mounting valve
nished wall
2-3/8" ± 1/2"
(60 mm ±13 mm)
pipe centerline
to nished wall
5) Remove protective shield
If attached in Step 3, then remove shield snap tted over the end of valve spindle once valve is securely installed and wall nish work has been completed.
6) Adjust valve packing nut
Reference gure 3
■ Turn hot & cold supplies on. Valve will not operate unless both hot
and cold water supply pressures are on.
■ Place handle over control spindle stem.
■ Adjust packing nut for positive frictional resistance as handle is rotated from shuto position across adjustment range.
Temp Limit
stop screw
packing nut
control
spindle
stem
Figure 3 Valve adjustments
7) Flush system and check for leaks
■ Turn valve to the warm position and run for a few minutes.
■ If system is dirty, remove valve spindle in center of valve to ensure proper ushing. (See service instructions.)
■ Check for leaks around valve assembly and all pipe ttings.
Dimensions Sereno Shower System, S-4301
nished wall
wall
8) Set Temp Limit stop screw
Reference gure 3
e limit stop screw limits valve handle from being turned to maximum position resulting in excessive hot water discharge temperatures.
■ Place handle on control spindle and open valve to maximum desired temperature.
■ Turn limit stop screw clockwise until it seats.
Note: devices on control valve outlet or devices that do not allow the valve to ow at least 1.5 gpm.
Do not install positive shut-o
Warning:
limit stop screw properly may result in serious scalding.
Failure to adjust
6"
(152 mm)
5-3/4"
(145 mm)
9-1/4"
(235 mm)
9-1/4"
(236 mm)
2-3/8" ± 1/2"
(60 mm ±13 mm)
pipe centerline
to nished wall
See note (2)
*
showerhead supply
approx
30"
(762 mm)
5/8" (16 mm)
1/2" (13 mm)
mounting plate,
See notes (1)(2)
*
Temptrol control valve
S-4001-BODY
tub spout supply plug
hot / cold supply
Notes:
*
(1) Valve spindle can be further extended through
thicker walls by removing mounting plate.
(2) Dimension applies when mounting plate is not used.
(3) Dimensions subject to change without notice.
Page 2