INSTALLATION:
Caution: Be sure to turn o hot and cold water supplies before installing or servicing faucet.
1.
Push valve bodies through holes in sink from underneath. Make sure mounting nuts (RT-103N) are on underside of sink. Valve marked Hot is on the le and Cold is on the right. Put gasket (LN-129) over valve body.  read escutcheon (LN-128) onto valve bodies.  e top of the valve spindle should measure 1-7/8” from mounting surface (See rough in drawing).
2.  read collar (LN-112 or LN-111) on to valve body until it reaches the escutcheon (LN-128). Tighten mounting nuts from underneath sink.
3. Standard or LWG handle installation: Place bushing (LN-115) on valve spindle. Turn valves to o position (CR style: turn clockwise; LWG, LCF, LPO, LAM, and standard style: turn hot clockwise, turn cold counterclockwise). Place handle (LN-131) on bushing.  read screw (LN-146 or LN-121) into valve and push plug button (T-33R and T-33B) into top of handle. CR, LCF, LPO and LAM handle installation: Place lever part of handle on valve spindle and thread screw (LN-121 or LN-134) into valve.
4. Swivel spout option: Place spout assembly (LN-200) in centerbody (LN-197).  read nut (LN-199) onto centerbody (LN-197). Rigid spout option:  read screw (LN-205) into the bottom of the spout assembly (LN-200). Place spout assembly (LN-200) in center body (LN-197).  read nut (LN-199) onto center body (LN-197).
5. Drop assembled center body and spout through center hole of deck.
Secure assembly to sink using nut (SPF-26) and washer (LN-138).
6.  read adapter (LN-189) onto the end of the center body (LN-197).  read  ex hoses (LN-157) into center body using pipe dope or te on tape on the pipe threads.  read  ex hoses (LN-157) into center body.  read other end to valve bodies. Note:  e adapter can be backed o a full turn to allow better positioning on the  ex hoses.
7. Connect hot supply to le tube and cold supply to right tube using appropriate connectors.
8. It is very important to thoroughly  ush the supply lines to prevent foreign matter, i.e. copper chips, sand, stones, etc. from damaging the sealing surfaces of cartridge. Remove aerator and open hot and cold to full open then open both supplies. Let water run through hot and cold long enough to  ush supply lines thoroughly. Shut o faucet and replace aerator. Check for leaks.
Cartridge Replacement (KN-113 or KN-114):
1. Remove plug button (T-33, T-33R or T-33B), loosen Philip head screw (LN-121) and remove handle, (LN-131 or LN 152).
2. Remove collars (LN-112) by turning counter clockwise, do not use wrench as this may damage the surface  nish.
3. Place wrench on cartridge hex nut (KN-113, KN-114). Turn wrench counter clockwise until cartridge is removed.
4. Install new cartridge. Turn cartridge with wrench until cartridge does not turn easily then turn 1/4 to 1/2 turn further. Reassemble handle in reverse fashion.
®
Dimensions Symmetrix, S-254, S-254-CR, S-254-LAM, S-254-LPO, S-254-LCF, S-254-LTM
S-254 standard handle shown
Escutcheon
S-254-LAM S-254-LPO S-254-LCF S-254-LTM
1-1/16" (27mm) min 1-7/16" (37mm) max hole size
7/8" (22mm) min 1-3/8" (35mm) max hole size
S-254-CR handle
Note: Dimensions subject to
change without notice.
DF-30 Finial, lever, handle (2) KN-113 Valve cartridge, cold KN-114 Valve cartridge, hot KN-120 O-ring (2) L-5 Aerator L-5NA Aerator (laminar) L-5VP Aerator (vandal-resistant) L-42 Nut (2) LN-111 Lock ring (2) LN-112 Collar (lever handle) (2) LN-115 Bushing (2) LN-121 Philips pan head screw (2) LN-128 Escutcheon, valve (2) LN-129 Gasket, escutcheon (2) LN-131 ADA handle (2) LN-133A Temperature indicator (red) LN-133B Temperature indicator (blue) LN-134 Oval Philips head screw (2) LN-138 Washer LN-140 Lever handle (2) LN-142 Valve body (HOT) LN-142A Valve body (COLD) LN-149 Clear, Lever, Handle (2) LN-150 O-ring LN-152 Lever, Handle (2) LN-153A White, Lever, Handle (2) LN-153B Chrome, Lever, Handle (2) LN-157 Flex hose (2) LN-177 Cross handle (2) LN-189 Adapter LN-197 Center body LN-199 Nut LN-200 Spout LN-205 Anti-rotation pin LN-218 O-ring P-26 Grid drain assembly (complete) RT-103N Nut Flanged SPF-26 Nut, Hex T-33B Plug Button, Blue T-33R Plug Button, Hot
LN-200
L-5 L-5NA L-5VP
T-33 T-33B T-33R
LN-121
LN-140
LN-111
LN-115 LN-128 LN-129
KN-114
RT-103N
LN-142
L-42
LN-157
P-26
LN-218
KN-120
LN-205 LN-199
LN-129
KN-113
LN-197
LN-150 LN-138 SPF-26
LN-189
LN-142A
Handle option: LPO, LAM, LCF
LN-134
LN-152
LN-133A, LN-133B
LN-153A, LN-153B LN-149
LN-112
LN-128
DF-30
Handle option: LWG
T-33 T-33B, T-33R LN-121
LN-131
LN-111
LN-115
Handle option: CR
T-33 T-33B, T-33R LN-121
LN-177
LN-112
LN-128
KN-114 Cartridge used for both hot and cold handles
NOTE: Two LN-142 Valve bodies are used in conjunction with this handle.
Aerator (ow regulator)
Part Number Standard Vandal Resistant
Aerator with removal tool
2.2 gpm (8.3L/min) SWA-17FR SWA-17VP
1.5 gpm (5.7L/min) FLR-111-1.5 ----
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667, (781) 848-2250 M-F 8:00 am - 7:30 pm EST or check our website at www.symmons.com for a list of Symmons distributors.
1.0 gpm (3.8L/min) FLR-111-1.0 ---­ .5 gpm (1.9L/min) LL-60B ----