Symmons S-250-0 Service Manual

Symmetrix
Lavatory Faucet S-250 Series
Installation and Service Instructions
Caution: Be sure to turn off hot and cold water supplies before installing or servicing faucet.
Installation
1. Push faucet supplies with rubber gasket through holes
in sink (make sure gasket [LL-126] is between faucet and sink). Secure faucet to sink by tightening  ange nuts (LL-125) from underside. (If sink or counter surface is uneven, use putty or sealant to make proper seal under base.)
2. Connect hot supply to le tube and cold supply to
right tube using appropriate connectors.
3. Pop-up drain installation:
a) Remove pop-up plug, tail piece and  ange from the
drain body. Make sure that locknut is threaded all the way down onto the body with  at friction washer in middle and beveled washer on top.
b) Apply plumbers putty or sealant to bottom of  ange.
c) Install drain body through drain opening in lava-
tory and screw  ange onto the drain body making sure that the threads are completely engaged for proper sealing and strength of the connection. Apply joint compound to all threaded parts to insure proper seal.
d) Tighten locknut to compress the beveled  ange
evenly across the bottom of the drain opening taking care not to over tighten the locknut, causing damage to the lavatory.
e) Remove one of two ball washers from inside the
threaded cavity. Insert pop-up plug and pivot rod into body. Add one ball washer (the second ball washer should remain inside the body) to the outside of the ball. Tighten the retaining nut until the ball is seated on the internal and external ball washers. Note:  e pop-up plug can be installed either in the removable or non-removable position, depending on the location of the hole located in the guide at the bottom of the plug.
f) Slide the pivot rod through one side of the spring
clip, then the appropriate adjustment hole and then other side of the spring clip.
g) Insert li rod through faucet housing and the top of
the li strap and secure it in place by tightening the screw. Note: To insure proper operation of li rod and pop-up, some adjustment of the linkage may be required.  ere are two possible adjustment points:
1) li strap to li rod and 2) li strap to pivot rod.
4. It is very important to thoroughly  ush the supply
lines to prevent foreign matter, i.e. copper chips, sand, stones, etc. from damaging the sealing surfaces of car­tridge. Remove aerator and open hot and cold to full open then open both supplies. Let water run through hot and cold long enough to  ush supply lines thor­oughly. Shut o faucet and replace aerator. Check for
leaks.
Replacing handle
1. Remove screw from top of handle. Remove red or blue
washer and then remove handle (LL-122) or (LL-123).
2. Reassemble handle (LL-122) or (LL-123) in reverse
fashion.
Replacing cartridge
1. Remove screw from top of handle. Remove red or blue
washer and then remove handle (LL-122) or (LL-123).
2. Unthread cartridge cover (LL-127) from faucet.
3. Place wrench on cartridge (LL-124) hex nut, turn
wrench counter clockwise until cartridge is removed.
4. Install new cartridge (LL-124). Turn cartridge with
wrench until cartridge does not turn easily then turn 1/4 to 1/2 turn further.
5. Reassemble cartridge cover (LL-127).
6. Reassemble (LL-122) or (LL-123) handle in reverse
fashion.
®
S-250-1
S-250-1-LWG
Dimensions Symmetrix Lavatory Faucet, S-250 Series
Note: Dimensions subject to
change without notice.
Parts Assembly Symmetrix Lavatory Faucet, S-250 Series
Lever handle
repair kit
LL-122
Cartridge cover
LL-127
Vandal proof
aerator and
removal tool
Wing handle repair kit
LL-123
Cartridge (2) LL-124
Gasket
LL-126
Flange nut (2)
LL-125
Nut (2)
L-42
Aerator
(ow regulator)
2.2 gpm (8.3L/min) LN-15* LN-101
1.5 gpm (5.7L/min) FLR-111-1.5
1.0 gpm (3.8L/min) FLR-111-1.0 .5 gpm (1.9L/min) ---- LN-100
Removal tool part number, LL-60K
Note: When ordering replacements parts for
*
faucets with an optional decorative nish, append appropriate three letter nish sufx code to part numbers marked with an asterisk (
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667, (781) 848-2250 M-F 8:00 am - 7:30 pm EST or check our website at www.symmons.com for a list of Symmons distributors.
Part Number Standard Vandal Resistant
Aerator with removal tool
* * *
----
----
*
).
*
Pop-up Drain Assembly
P-25LR
Grid Drain Assembly
P-26
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800) 796-6667, (781) 848-2250 Website: www.symmons.com
©2002, 2005, 2008 Symmons Industries, Inc. Printed in U.S.A.
Fax (800) 961-9621, (781) 664-1300
Email: customerservice@symmons.com
ZV-420 043009
Loading...