Symmons S-244 Service Manual

Symmetrix®
Lavatory Faucet
S-244 Series
INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS
Faucet meets ANSI A112.18.1M Flow rate: 2.2 gpm (8.3 L/min)
Caution: Be sure to turn o hot and cold water supplies before installing or servicing faucet.
INSTALLATION:
2. Thread collar (LN-112 or LN-160) on to valve body until it reaches the escutcheon (LN-128). Tighten flange nuts from underneath sink. Secure with mounting screws if necessary.
3. LCT or LWG handle installation: Place bushing (LN-115 or LN-154) on valve spindle. Turn valves to o position (LCT style: turn clockwise, LWG, LCF, LPO and LAM style: turn hot clockwise, turn cold counterclockwise). Place handle (LN-131 or LN-151) on bushing. Thread screw (LN-146 or LN-121) into valve and push plug button (T-33R and T-33B) into top of handle.
LCF, LPO and LAM handle installation: Place lever part of handle
on valve spindle and thread screw (LN-134) into valve.
4. Install spout (LN-124) and centerbody (LN-141) through center in sink hole from above sink. Secure spout to sink with washer (LN-138) and nut (SPF-26). Washer (LN-138) flat should face back of the sink. Thread tee (LN-141) to bottom of centerbody (LN-141).
5. Thread flex hose adapters into tee (LN-141) using pipe dope or teflon tape on the adapter threads. Attach flex hoses to flex hose adapters.
6. Connect hot supply to left tube and cold supply to right tube using appropriate connectors.
7. Pop-up drain installation: a) Remove pop-up plug, tail piece and flange from the drain
body. Make sure that locknut is threaded all the way down onto the body with flat friction washer in middle and beveled
washer on top. b) Apply plumbers putty or sealant to bottom of flange. c) Install drain body through drain opening in lavatory and
screw flange onto the drain body making sure that the
threads are completely engaged for proper sealing and
strength of the connection. Apply joint compound to all
threaded parts to insure proper seal. Apply putty or teflon
tape to tail piece before attaching to drain body. d) Tighten locknut to compress the beveled flange evenly across
the bottom of the drain opening taking care not to over
tighten the locknut, causing damage to the lavatory. e) Remove one of two ball washers from inside the threaded
cavity. Insert pop-up plug and pivot rod into body. Add one
ball washer (the second ball washer should remain inside the
body) to the outside of the ball. Tighten the retaining nut until
the ball is seated on the internal and external ball washers.
Note: The pop-up plug can be installed in the removable or
non-removable position, depending on the location of the
hole located in the guide at the bottom of the plug. f) Slide the pivot rod through one side of the spring clip, then
the appropriate adjustment hole and then other side of the
spring clip. g) Insert lift rod through faucet housing and the top of the lift
strap and secure it in place by tightening the screw. Note: To
insure proper operation of lift rod and pop-up, some adjust-
ment of the linkage may be required. There are two possible
adjustment points: 1) lift strap to lift rod and 2) lift strap to
pivot rod.
8" - 203 mm min
11⁄
" - 33mm
4
3
2 " 55mm
16
11⁄16" min (27mm)
7
1
16" max
(37mm)
1
"-14 NPSM
2
7
1
47mm
16" - 406 mm max
4"
102mm min
15
2
"
16
75mm
41⁄
"
4
108mm
"
8
13
"
16
21mm
76mm
11⁄
8
29mm
13⁄
8
35mm
3"
"min
"max
4"
102mm
ESC
2" - 51mm
13⁄
" 35mm max deck
8
Flex hoses
7
"
1
8
47mm
1"
25mm
3
3
98mm
8. It is very important to thoroughly flush the supply lines to prevent foreign matter, i.e. copper chips, sand, stones, etc. from damaging the sealing surfaces of cartridge. Remove aerator and open hot and cold to full open then open both supplies. Let water run through hot and cold long enough to flush supply lines thoroughly. Shut o faucet and replace aerator. Check for leaks.
To replace cartridge (KN-113 or KN-114):
1. Remove plug button (T-33, T-33R or T-33B), loosen Philip head screw (LN-121) and remove handle, LN-131, LN-151 or LN 152.
2. Remove collars LN-160 or LN-112 by turning counter clock­wise, do not use wrench as this may damage the surface finish.
3. Place wrench on cartridge hex nut (KN-113, KN-114). Turn wrench counter clockwise until cartridge is removed.
4. Install new cartridge. Turn cartridge with wrench until car­tridge does not turn easily then turn 1/4 to 1/2 turn further. Reassemble handle in reverse fashion.
"
8
DF-30* Finial, lever, Handle (2) LN-138
Washer
KN-113 KN-114 L-42 LN-15* LN-111* LN-112* LN-115 LN-121 LN-124* LN-127 LN-128* LN-129 LN-131 LN-133A LN-133B LN-134* LN-138 LN-141 LN-146 LN-149 LN-150 LN-151 LN-152* LN-153A LN-153B LN-154 LN-160* LN-100
LN-101* RL-154* P-26*
SPF-26 T T T
*For Decorative Finish Faucets add suffix to parts marked with an asterisk as follows:
Suffix BRS: Suffix STN:
Valve cartridge, cold Valve cartridge, hot Nut (2) Aerator Lock ring (2) Collar (lever handle) (2) Bushing (2) Philips pan head screw (2) Spout Gasket, Spout Escutcheon, valve (2) Gasket, Escutcheon (2) ADA handle (2) Temperature indicator (red) Temperature indicator (blue) Oval Philips head screw (2) Washer Centerbody Screw (2) Clear, Lever, Handle (2) O-ring (2) Handle, Acrylic (2) Lever, Handle (2) White, Lever, Handle (2) Chrome, Lever, Handle (2) Bushing, Acrylic (2)
-33* Plug Button (2)
-33B Plug Button, Blue
-33R Plug Button, Hot
Collar (acrylic handle) (2) Aerator (vandal resistant
0.5 gpm) Aerator (vandal resistant) Pop-up drain assembly Grid drain assembly (complete) Nut, Hex
Radiance® polished brass finish Satin finish
Symmons warrants to the original consumer purchaser that any TEMPTROL® series* or SYMMETRIX® product will be free of defects in material and workmanship during normal domestic use for the life of your home. All other products and purchasers including industrial, commercial or business use are warranted for a period of 5 years from the date of purchase. At our option, we will either have you send the defective part or product prepaid to us for inspection, or we may elect to send you the replacement part or product without investigation. A replacement for any defective part will be supplied FREE OF CHARGE for installation by the purchaser. Defect or damage caused by the use of replacement parts other than Symmons Genuine Replacement Parts will void this warranty. This warranty excludes product damage due to installation error, product abuse, or product misuse whether performed by a contractor, service company or yourself. Symmons further warrants that any TEMPTROL or SYMMETRIX product will be leak free and drip free during normal domestic use for the life of your home. If the product should develop a leak or drip, Symmons will provide FREE OF CHARGE the parts necessary to return it to good working condition. Proof of purchase (original sales receipt) and a copy of the warranty registration card from the original consumer purchaser must accompany all warranty claims. This warranty is applicable only to Symmons TEMPTROL or SYMMETRIX products purchased after July 1, 1998 and shall be effective from the date of purchase as shown on the purchaser’s receipt. Damage to the chrome and/or other decorative finishes on Symmons products may be a result of improper handling or abusive treatment. Finishes should only be cleaned with a soft, damp cloth or sponge. Use of polish, abrasive cleaners, solvents, or acid cleaners will damage the finish and void this warranty. There are no other express warranties on this product and ALL WARRANTIES OF MERCHANTABILITY AND OTHER IMPLIED WARRANTIES ARE LIMITED IN ACCORDANCE WITH APPLICABLE LAW. SYMMONS INDUSTRIES, INC., EXPRESSLY DISCLAIMS CONTINGENT LIABILITY AND CONSEQUENTIAL DAMAGE OF EVERY KIND. Since some states do not allow limitations on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages the above limitation or exclusion may not be applicable. This warranty gives specific legal rights. Other rights may vary from state to state. To obtain warranty service, write to Symmons Industries, Inc., 31 Brooks Drive, Braintree, MA at 1-800-SYMMONS. If writing to us, please include proof of purchase, the model number of the product with a brief description of the problem, your name, address and phone number. *Temptrol series includes Allura®, Olde Braintree Brass®, Temptrol, Temptrol Deluxe and Temptrol II shower and tub/shower systems. Symmons warrants to the original consumer purchaser that any TEMPTROL® series* or SYMMETRIX® product will be free of defects in material and
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 Website: www.symmons.com Email: gethelp@symmons.com
©2014 Symmons Industries, Inc. Printed in U.S.A. ZV-364 Rev B 101514
LN-129
KN-114
LN-124
LN-15
LN-100 LN-101
Valve body
Mounting washer
Flange nut
Mounting screws
(red label on hot valve)
Flex hose adapter
Flex hose
Lifetime Limited Warranty
02184-3804 or call our Customer Service Department
Handle option: LPO, LAM, LCF
LN-134
LN-152
LN-133A, LN-133B
LN-153A, LN-153B
LN-112
LN-128
KN-113
LN-149
DF-30
Handle option: LWG
T-33
T-33B, T-33R
LN-121
LN-131
LN-111
LN-115
LN-141
LN-127
LN-138
SPF-26
LN-150
Handle option: LCT
T-33
T-33B, T-33R
LN-146
LN-151
LN-160
LN-154
P-26
RL-154
NOTE: Two LN-142 Valve bodies are used in
conjunction with this handle.
workmanship during normal domestic use for the life of your home. All other products and purchasers including industrial, commercial or business use are warranted for a period of 5 years from the date of purchase. At our option, we will either have you send the defective part or product prepaid to us for inspection, or we may elect to send you the replacement part or product without investigation. A replacement for any defective part will be supplied FREE OF CHARGE for installation by the purchaser. Defect or damage caused by the use of replacement parts other than Symmons Genuine Replacement Parts will void this warranty. This warranty excludes product damage due to installation error, product abuse, or product misuse whether performed by a contractor, service company or yourself. Symmons further warrants that any TEMPTROL or SYMMETRIX product will be leak free and drip free during normal domestic use for the life of your home. If the product should develop a leak or drip, Symmons will provide FREE OF CHARGE the parts necessary to return it to good working condition. Proof of purchase (original sales receipt) and a copy of the warranty registration card from the original consumer purchaser must accompany all warranty claims. This warranty is applicable only to Symmons TEMPTROL or SYMMETRIX products purchased after July 1, 1998 and shall be effective from the date of purchase as shown on the purchaser’s receipt. Damage to the chrome and/or other decorative finishes on Symmons products may be a result of improper handling or abusive treatment. Finishes should only be cleaned with a soft, damp cloth or sponge. Use of polish, abrasive cleaners, solvents, or acid cleaners will damage the finish and void this warranty. There are no other express warranties on this product and ALL WARRANTIES OF MERCHANTABILITY AND OTHER IMPLIED WARRANTIES ARE LIMITED IN ACCORDANCE WITH APPLICABLE LAW. SYMMONS INDUSTRIES, INC., EXPRESSLY DISCLAIMS CONTINGENT LIABILITY AND CONSEQUENTIAL DAMAGE OF EVERY KIND. Since some states do not allow limitations on how long an incidental or consequential damages the above limitation or exclusion may not be applicable. This warranty gives specific legal rights. Other rights may vary from state to state. To obtain warranty service, write to Symmons Industries, Inc., 31 Brooks Drive, Braintree, MA 02184-3804 or call our Customer Service Department at 1-800-SYMMONS. If writing to us, please include proof of purchase, the model number of the product with a brief description of the problem, your name, address and phone number. *Temptrol series includes Allura®, Olde Braintree Brass®, Temptrol, Temptrol Deluxe and Temptrol II shower and tub/shower systems.
KN-114 Cartridge used for both hot and cold handles
implied warranty lasts or an exclusion or limitation of